i-Vu® XT Router
XT-RB

Network & Integration Device

The i-Vu® XT Router routes BACnet messages between the i-Vu building automation system backbone (BACnet/IP), and a subnetwork of i-Vu controllers (BACnet MS/TP and/ or BACnet ARCnet). It connects directly to the Ethernet LAN and provides the i-Vu web server with access to the entire i-Vu system.

The i-Vu XT Router also extends an i-Vu system, allowing individual BACnet MS/TP networks (with up to 60 controllers each), and BACnet ARCnet networks (with up to 99 controllers each), to be connected together via the i-Vu building automation system backbone.


carrier-bacnet-testing-laboratories
Power Requirements 24VAC ± 10%, 50-60Hz, 50 VA
26VDC ± 10%, 15W
Communication Ports Gig-E: 10/100/1000 BaseT Ethernet port for BACnet/IP and/or BACnet/Ethernet communication

ARC/MSTP: High-speed EIA-485 port for connecting one of the following network types:
› BACnet ARCnet network at 156 kbps
› BACnet MS/TP network at 9.6, 19.2, 38.4, 57.6, 76.8, or 115.2 kbps
An End of Net switch can be turned on to terminate the network segment.

MSTP: Electrically isolated EIA-485 port for connecting BACnet MS/TP network at 9.6, 19.2, 38.4, 57.6, 76.9, or 115.2 kbps. An End of Net switch can be turned on to terminate the network segment.

Local Access: 10/100 Base T Ethernet port for system start-up and troubleshooting.
Protection Device is protected by a replaceable, fast acting, 250Vac, 2A, 5mm x 20mm glass fuse. The power and network ports comply with the EMC requirements EN50491-5-2.
Real-Time Clock Real-time clock keeps track of time in the event of a power failure for up to 3 days.
LED Status Indicators Tricolor NET LED to show network status
Tricolor SYS LED to show system status
A TX (Transmit) and RX (Receive) LED for:
› Gig-E port
› ARC/MSTP port
› MSTP port
Router Addressing Rotary DIP switches set address of router
Environmental Operating Range Operating: 0 to 140ºF (-18 to 60ºC); 10 to 90% RH, non-condensing
Storage: -24 to 140ºF (-30 to 60ºC); 10 to 90% RH, non-condensing
Compliance United States of America: FCC compliant to Title CFR47, Chapter 1, Subchapter A, Part 15, Subpart B, Class A; UL listed to UL916, PAZX, Energy Management Equipment Canada: Industry Canada Compliant, ICES-003, Class A; cUL listed UL 916, PAZX and Energy Management Equipment Europe: CE mark, EN50491-5-2:2009 , Part 5-2: EMC requirements for HBES/BACS used in residential, commercial and light industry environment; EN50491-3: 2009, Part 3: Electrical safety requirements for Home and Building Electronic Systems (HBES) and Building Automation and Control Systems (BACS); Low Voltage Directive: 2006/95/EC; RoHS Compliant: 2011/65/EU Australia and New Zealand: C-Tick Mark, AS/NZS 61000-6-3;
Physical Fire-retardant plastic ABS, UL94-5VA
Dimensions Overall
A: 7.1” (18.03 cm)
B: 6.95” (17.65 cm)

Mounting
DIN rail mount or screw mount
C: 6.45” (16.38 cm)
D: 4.1” (10.4 cm)

Depth: 2.79” (7.09 cm)

Weight: 1.1 lbs. (.482 kg)
Power Requirements 24VAC ± 10%, 50-60Hz, 50 VA
26VDC ± 10%, 15W
Communication Ports Gig-E: 10/100/1000 BaseT Ethernet port for BACnet/IP and/or BACnet/Ethernet communication

ARC/MSTP: High-speed EIA-485 port for connecting one of the following network types:
› BACnet ARCnet network at 156 kbps
› BACnet MS/TP network at 9.6, 19.2, 38.4, 57.6, 76.8, or 115.2 kbps
An End of Net switch can be turned on to terminate the network segment.

MSTP: Electrically isolated EIA-485 port for connecting BACnet MS/TP network at 9.6, 19.2, 38.4, 57.6, 76.9, or 115.2 kbps. An End of Net switch can be turned on to terminate the network segment.

Local Access: 10/100 Base T Ethernet port for system start-up and troubleshooting.
Protection Device is protected by a replaceable, fast acting, 250Vac, 2A, 5mm x 20mm glass fuse. The power and network ports comply with the EMC requirements EN50491-5-2.
Real-Time Clock Real-time clock keeps track of time in the event of a power failure for up to 3 days.
LED Status Indicators Tricolor NET LED to show network status
Tricolor SYS LED to show system status
A TX (Transmit) and RX (Receive) LED for:
› Gig-E port
› ARC/MSTP port
› MSTP port
Router Addressing Rotary DIP switches set address of router
Environmental Operating Range Operating: 0 to 140ºF (-18 to 60ºC); 10 to 90% RH, non-condensing
Storage: -24 to 140ºF (-30 to 60ºC); 10 to 90% RH, non-condensing
Compliance United States of America: FCC compliant to Title CFR47, Chapter 1, Subchapter A, Part 15, Subpart B, Class A; UL listed to UL916, PAZX, Energy Management Equipment Canada: Industry Canada Compliant, ICES-003, Class A; cUL listed UL 916, PAZX and Energy Management Equipment Europe: CE mark, EN50491-5-2:2009 , Part 5-2: EMC requirements for HBES/BACS used in residential, commercial and light industry environment; EN50491-3: 2009, Part 3: Electrical safety requirements for Home and Building Electronic Systems (HBES) and Building Automation and Control Systems (BACS); Low Voltage Directive: 2006/95/EC; RoHS Compliant: 2011/65/EU Australia and New Zealand: C-Tick Mark, AS/NZS 61000-6-3;
Physical Fire-retardant plastic ABS, UL94-5VA
Dimensions Overall
A: 7.1” (18.03 cm)
B: 6.95” (17.65 cm)

Mounting
DIN rail mount or screw mount
C: 6.45” (16.38 cm)
D: 4.1” (10.4 cm)

Depth: 2.79” (7.09 cm)

Weight: 1.1 lbs. (.482 kg)