AXIS™ Quiet Parallel Fan-Powered Terminal
45N
Up to 2,000 Cfm (Fan Airflow)
Up to 3,660 Cfm (Primary Airflow)
The 45N fan-powered units provide a combination of primary air cooling or plenum induction and reheat to meet most application needs at the lowest possible sound levels.
Performance Features
- Fan airflow capacities from 50 to 2000 CFM
- Primary airflow capacities from 52-3660 CFM
- Ultra quiet operation for critical sound applications
- Round inlet sizes from 6 in. through 16 in. diameter
- 20 gage, galvanized steel casing construction
- Integral induced air sound attenuator
- Suitable for low, medium, or high pressure applications
- Linear, multiple-point, averaging velocity sensor with an amplified signal
- Damper blade has a flexible gasket for tight airflow shutoff
- Damper blade operates over a full 90 degrees
- All damper assemblies utilize a solid ½ in. shaft that rotates in self-lubricating Delrin® bearings
- Pressure independent or dependent controls, including Carrier i-Vu Open (BACnet), Carrier Comfort Network® (CCN), analog, or pneumatic controls
- Electric or hot water reheat coils
- Multiple casing liners available
- Electric heat (1 to 3 stages) or proportional (SSR) heat
- Unit casing lined with ½ in. thick, 1-1/2 lb dual density fiberglass insulation that meets UL 181 and NFPA 90A
- Certified performance in accordance with ARI Standard 880
Reliability Features
- 20 gage, galvanized steel heaters are ETL listed in accordance with UL standards
- Heaters equipped with:
- Primary automatic and secondary manual reset thermal cutout
- Deenergizing magnetic contactors
- Airflow proving switch
- 80/20 Ni-Cr elements
- Strong integral panel/post construction for product durability
Maintenance Features
- NEMA 2 steel control enclosure for electric or electronic components
- Removable bottom access panel for easy accessibility during routine inspections and maintenance
- Label information adhered to each unit includes model, size, airflow (cfm), balancing chart, and tagging data
Installation Features
- Rectangular discharge with slip and drive connections provides quick and easy connection to downstream ductwork
- Compact unit casing accommodates installation in reduced ceiling plenum space
- Factory-installed controls
- All round collars accommodate standard spiral and flex duct sizes
- Balancing taps provided for easy airflow verification
- Single point electrical connection
Standard Warranty
- One-year parts
Factory-Installed Options
- Control options:
- Analog electronic controls
- Carrier i-Vu Open VAV Controls
- Carrier Comfort Network (CCN) VAV Controls
- Pneumatic controls
- No controls or field-supplied DDC (direct digital controls) third party controls
- Left-hand or right-hand control enclosure (dust-tight)
- Hanger brackets
- Hot water coils (1 or 2 rows)
- Liner options:
- 1 in. thick, dual density fiberglass
- Cellular
- Steriliner (foil-faced duct board)
- Sterilwall (double wall)
- Foil encapsulated fiberglass
- Perforated double wall
- None
- Vent and drain on water coils
- Electric heat (1 to 3 stages)
- Proportional SSR (solid-state relays) electric heat
- Electric heater options:
- Fused door interlocking disconnect switch
- Non-fused door interlocking disconnect switch
- Mercury contactors
- Fuse block with fuses for primary overload protection
- Dust-tight construction
- Motor fusing
- Recirculated air filter
- ECM (electronically commutated motor) motors
Field-Installed Accessories
- Remote wall sensor
- Supply-air temperature sensor
- CO2 sensor
Performance Features
- Fan airflow capacities from 50 to 2000 CFM
- Primary airflow capacities from 52-3660 CFM
- Ultra quiet operation for critical sound applications
- Round inlet sizes from 6 in. through 16 in. diameter
- 20 gage, galvanized steel casing construction
- Integral induced air sound attenuator
- Suitable for low, medium, or high pressure applications
- Linear, multiple-point, averaging velocity sensor with an amplified signal
- Damper blade has a flexible gasket for tight airflow shutoff
- Damper blade operates over a full 90 degrees
- All damper assemblies utilize a solid ½ in. shaft that rotates in self-lubricating Delrin® bearings
- Pressure independent or dependent controls, including Carrier i-Vu Open (BACnet), Carrier Comfort Network® (CCN), analog, or pneumatic controls
- Electric or hot water reheat coils
- Multiple casing liners available
- Electric heat (1 to 3 stages) or proportional (SSR) heat
- Unit casing lined with ½ in. thick, 1-1/2 lb dual density fiberglass insulation that meets UL 181 and NFPA 90A
- Certified performance in accordance with ARI Standard 880
Reliability Features
- 20 gage, galvanized steel heaters are ETL listed in accordance with UL standards
- Heaters equipped with:
- Primary automatic and secondary manual reset thermal cutout
- Deenergizing magnetic contactors
- Airflow proving switch
- 80/20 Ni-Cr elements
- Strong integral panel/post construction for product durability
Maintenance Features
- NEMA 2 steel control enclosure for electric or electronic components
- Removable bottom access panel for easy accessibility during routine inspections and maintenance
- Label information adhered to each unit includes model, size, airflow (cfm), balancing chart, and tagging data
Installation Features
- Rectangular discharge with slip and drive connections provides quick and easy connection to downstream ductwork
- Compact unit casing accommodates installation in reduced ceiling plenum space
- Factory-installed controls
- All round collars accommodate standard spiral and flex duct sizes
- Balancing taps provided for easy airflow verification
- Single point electrical connection
Standard Warranty
- One-year parts
Factory-Installed Options
- Control options:
- Analog electronic controls
- Carrier i-Vu Open VAV Controls
- Carrier Comfort Network (CCN) VAV Controls
- Pneumatic controls
- No controls or field-supplied DDC (direct digital controls) third party controls
- Left-hand or right-hand control enclosure (dust-tight)
- Hanger brackets
- Hot water coils (1 or 2 rows)
- Liner options:
- 1 in. thick, dual density fiberglass
- Cellular
- Steriliner (foil-faced duct board)
- Sterilwall (double wall)
- Foil encapsulated fiberglass
- Perforated double wall
- None
- Vent and drain on water coils
- Electric heat (1 to 3 stages)
- Proportional SSR (solid-state relays) electric heat
- Electric heater options:
- Fused door interlocking disconnect switch
- Non-fused door interlocking disconnect switch
- Mercury contactors
- Fuse block with fuses for primary overload protection
- Dust-tight construction
- Motor fusing
- Recirculated air filter
- ECM (electronically commutated motor) motors
Field-Installed Accessories
- Remote wall sensor
- Supply-air temperature sensor
- CO2 sensor
California residents please see Proposition 65