i-Vu UPC Open OPN-UPC

i-Vu® UPC Open

Technical Specifications

Features

Factory-Installed Features

 

Factory-installed option on rooftops, air-cooled chillers, and water-cooled chillers

Pre-programmed to share equipment data with any BACnet Building Automation System - no on-site engineering required

Supports Carrier communicating space sensors with field programming:

Ideal for single zone rooftop applications

Available in 4 flavors, 2 of which have large, easy-to-read LCD displays

Feature a hidden communication port for network commissioning

Supports plug-and-play connectivity to Carrier’s i-Vu Building Automation System:

Integrated air source linkage algorithm

Built-in user interface graphics, diagnostic trends and alarms

Built-in demand limiting and inherent support for i-Vu Tenant Billing

 

Field-Installed Benefits

 

Library of CCN to BACnet mapping templates available for common Carrier equipment, or create your own template using the Snap graphical programming tool

Integrated air source linkage algorithm for plug-and-play connectivity to the i-Vu Building Automation System

Supports demand limiting and i-Vu Tenant Billing

Specifications

Communication PortsBAS port (Port 1A): EIA-485 port for BACnet MS/TP communications, Modbus communications or N2 communications (future). Baud rate is DIP switch selectable.
LON-OC Port: For connecting a LON Option Card (future)
Local Access Port: For system start-up and troubleshooting (115.2 kbps)
Rnet Port: For connecting Carrier communicating space sensors
ProtectionIncoming power and network connections are protected by non-replaceable internal solidstate polyswitches that reset themselves when the condition that causes a fault returns to normal. The power, network, input, and output connections are also protected against voltage transient and surge events.
Real Time ClockBattery-backed real time clock
Battery10-year Lithium CR2032 battery provides a minimum of 10,000 hours of trend data and time retention during power outages.
Status IndicatorsLED status indicators for power, network communication, run status and errors.
Controller AddressingRotary DIP switches set BACnet MS/TP MAC address of controller
Listed ByUL-916 (Canadian Std C22.2 No. 205-M1983), CE, FCC Part 15-Subpart B-Class A
Status IndicatorsLED status indicators for IP and S1 communications, run status, error, power, all outputs, and locator LEDs for controller identification and actuator rotation feedback
Environmental Operating RangeOperating: -22° to 150°F (-30° to 66°C), 10-95% relative humidity, non-condensing
Storage: -24°F to 140°F (-30° to 60°C), 10-95% relative humidity, non-condensing
Power Requirements24VAC +/- 10%, 50-60Hz
10VA power consumption
26VDC (25V min, 30V max)
Single Class 2 source only, 100VA or less
DimensionsLength: 5-3/16” (13.2 cm)
Width: 4-1/8” (10.5 cm)
Depth: 2” (5.1 cm)
Weight: 0.44 lbs. (0.20 kg)

Documents

Installation

UPC Open Installation and Start-up Guide

Open Controller Network Wiring Guide

Product Data

i-Vu Open UPC Open Factory Installed Product Data Sheet

i-Vu Open UPC Open Field Installed Product Data Sheet

White Paper

Intelligent Air Source and Terminal Integration

Environmental Design Considerations for Hospital Operating Rooms White Paper