TruVu™ Dual IP Bypass Controller
Technical Specifications
Features
Application Features
Sophisticated factory-engineered and tested control programs provide reliability and energy efficiency
Temperature protection minimizes the occurrence of air source heating and/or cooling lockouts based on unacceptable discharge temperatures
Provides automatic pressure sensor calibration
Can drive multiple damper actuators
VFD support via 0-10VDC analog output to provide drive speed modulation
Supports two simultaneous application control programs for customized application solutions
Programmable control of dampers, VFDs and other auxiliary equipment using Snap graphical programming
Supports Carrier communicating sensors which are available in a variety of zone and equipment sensing combinations
Supports Carrier TruVu touchscreen interfaces for managing and troubleshooting the connected equipment easily and for occupant engagement
Conforms to the BACnet Advanced Application Controller (B-AAC) Standard Device and BACnet Broadcast Management Device (B-BMD), as defined in BACnet 135-2001 2012 Annex L and tested to Protocol Revision 15
System Benefits
Integrated Carrier airside linkage algorithm for plug-andplay integration with Carrier air sources
Fully plug-and-play with the i-Vu building automation system
Hardware Features
Integrated 45 in-lb 154 second actuator for reliability and longevity
Dual 10/100 Mbps, BACnet IP and DCHP IP addressing
Native BACnet IP or MS/TP communications
Supports home run, daisy chain and ring IP network topologiesntegral airflow sensor
Capacitor-backed real-time clock keeps time in the event of power failure or network interruption for up to three days
Controls up to 9 points (3 binary outputs, 4 universal inputs and 2 analog output) plus up to 2 Act Net Smart Actuators
USB port for local device updates, hard-wired, and wireless service connections
Reversible airflow connections allows for error free tube installation
Specifications
| BACnet Conformance | Conforms to the BACnet Advanced Application Controller (B-AAC) and BACnet Broadcast Management Device (B-BBMD) standard device profiles, as defined in BACnet 135-2012 Annex L Protocol rev. 15 |
| Communication Ports | BAS Primary Port: Dual 10/100 BaseT Ethernet ports with built-in fail safe, supporting direct connection or daisy chain topology natively using BACnet/IP (non-routing) Serial Port 1 EIA-485 port for BACnet MS/TP communications (9600 bps to 115.2 kbps) Rnet Port: 12Vdc @ 260mA supports the following: Up to 10 ZS sensors (mix ZS zone, ZS duct, ZS immersion and ZS outdoor sensors), i-Vu Equipment Touch, or TruVu ET Displays (external power required) Act Net Port: Supports up to 2 Act Net communicating i-Vu smart valves USB Port: For TruVu ET Display support |configuration | wireless service access | firmware updates and controller recovery via USB drive |
| Power Requirements | 24Vac +/- 15% , 50 - 60Hz, 50VA | 24Vdc +/- 10%, 18W. (75VA / 35W if additional Act Net devices are connected) |
| Integral Pressure Sensor | Precision low flow AWM series 0–2 in. H2O, sensitive down to ±0.001 in. H2O. Barbed tapered airflow connections accept 3/16 in. (4.75 mm) I.D. tubing. Allows for readings across the 0–2 in. H2O range, accurate to ±3% of reading. Reversible connections |
| Inputs | Universal: 4 Universal Inputs electronically configurable to any of the following types: Dry | Pulse Counting |Thermistor | 0-10 Vdc |
| Outputs | Analog: 2 Analog Outputs 10Vdc (D/A Resolution 12 bits) | PWM 12Vdc @ 80Hz) Digital: 3 Digital outputs (Dry Contact) Rated @30Vac/Vdc @ 1.4 Amp. Configured normally open |
| Actuator | Brushless DC motor, torque 45 inch-pounds (5Nm), runtime 154 seconds for 90 degree travel during control |
| Memory | 4 GBs eMMC Flash memory and 256 MB DDR3 DRAM. User data is archived to non-volatile flash memory when parameters are changed, every 90 seconds |
| Status Indicators | LED status indicators for IP and S1 communications, run status, error, power, all outputs, and locator LEDs for controller identification and actuator rotation feedback |
| Compliance | United States of America: FCC compliant to Title CFR47, Chapter 1, Subchapter A, Part 15, Subpart B, Class B; UL Listed to UL 916, PAZX, Energy Management Equipment RoHS Compliant: 2015/863/EU ANZ: C-Tick Mark AS/NZS 61000-6-3 Canada: Industry Canada Compliant, ICES-003, Class B cUL Listed UL 916, PAZX,Energy Management Equipment, CE mark |
| Real Time Clock | Real-time clock keeps track of time in the event of a power failure for at least 3 days |
| Environmental Operating Range | Operating Range: 32 to 122ºF (0 to 50ºC) 10 to 95% RH, non-condensing Storage: -24 to 140ºF (-30 to 60ºC) 0 to 90% RH, non-condensing |
| Plastic Rating | Fire-retardant plastic ABS, UL94-5VA |
Documents
Case Study
Escondido Union School District: Sustainable Building Management
Installation
Ethernet Wiring for TruVu™ Dual IP Port Controllers
TruVu VVTBP-E2 Installation and Start-up Guide
TV-VAVB3-E2 TV-VVTBP-E2 TV-VVTZC-E2 Mounting Instructions
Product Data
TruVu™ TV-VVTBP-E2 Product Data