i-Vu® UC Open XP

Technical Specifications

Features

Application Features
 

Comprehensive library of factory-engineered control programs available, including: Pump Control, Lighting Control, Time Scheduling with/without Override, Analog Temperature Control, Discrete & Permissive Interlock, Discrete Staging Control, OA Conditions, BTU Metering, Fuel Oil Metering, Electric Metering, Gas Metering, and Water Metering

Supports Snap graphical programming for creating customized control programs

Supports Carrier communicating room sensors, which allow for local setpoint adjustment and local overrides

 

Hardware Features
 

Expands the UC Open XP Controller to support up to 48 I/O points

Removable screw terminals for I/O connections

Versatile mounting options: may be mounted directly onto the UC Open XP enclosure or separately within the mounting enclosure

 

System Benefits
 

Integrated Carrier linkage algorithm for plug-and-play integration with Carrier systems

Fully plug-and-play with the Carrier i-Vu Building Automation System

Supports demand limiting for maximum energy savings

Specifications

BACNet SupportAdvanced application controller (B-AAC), as defined in BACNet 135-2001 Annex L
Communication PortsBACnet port: EIA-485 port for BACnet MS/TP communications (baud rate is DIP switch selectable)
Local Access port: For system start-up and troubleshooting (115.2 kbps)
Rnet port: For connecting Carrier communicating room sensors and Carrier's touchscreen user interface
Inputs12 inputs: Configurable for 0-10V, RTD/Thermistor/Dry contact, or 0-20mA. Inputs 1 and 2 may be used for pulse counting. All analog inputs have 12 bit A/D resolution.
Outputs6 binary outputs: Configured as dry contact, normally open or normally closed. All binary outputs must be powered from a Class 2 power source.
6 analog outputs: 1 and 2 are configurable for 0-10V or 0-20mA; 3-6 are 0-10V only. Analog outputs have 8 bit D/A resolution.
ProtectionIncoming power and network connections are protected by non-replaceable internal solidstate polyswitches that reset themselves when the condition that causes a fault returns to normal. The power, network, input, and output connections are also protected against voltage transient and surge events.
Real Time ClockBattery-backed real time clock keeps track of time in event of power failure
Battery10-year Lithium CR2032 battery provides a minimum of 10,000 hours of trend data & time retention during power outages.
Status IndicatorsLED status indicators for communications, run status, error, and power.
Controller AddressingRotary DIP switches set BACnet MS/TP MAC address of controller.
Listed ByUL-916, FCC Part 15-Subpart B- Class A, CE EN50082-1997
Environmental Operating RangeOperating: -24° to 140°F (-30° to 60°C), 10-90% relative humidity, non-condensing
Storage: -24°F to 140°F (-30° to 60°C), 10-90% relative humidity, non-condensing
Power Requirements24VAC +/- 10%, 50-60Hz
18VA power consumption
26VDC (25V min, 30V max
Single Class 2 source only, 100VA or less

Documents

Brochure

VVT Zoning System Brochure Low Resolution 1/21

VVT Zoning System Brochure High Resolution 1/21

VVT Zoning System Brochure Print Version 1/21

Case Study

evolv1 building

Controls

i-Vu Open General Purpose Controller Guide Specification

i-Vu - Source Water Loop Control for UC Open XP Installation and Start-up Guide

Installation

Open Controller Network Wiring Guide

UC Open XP/UC Open XP IO Installation and Startup Guide

Product Data

i-Vu Open UC Open XP Controller Product Data Sheet

Warranty Card

Limited Warranty for i-Vu Control System and Field-Installed Open Controls

Need assistance? Ask Carrier.

Get in touch