i-Vu® General Purpose AppController
Technical Specifications
Features
Application Features
Library of factory-engineered control programs for fan coils, unit ventilators, water source heat pumps, and constant volume AHUs
Supports Snap graphical programming for creating customized control programs
Supports Carrier communicating room sensors, which allow for local setpoint adjustment and local overrides
Hardware Features
Battery-backed real time-clock keeps time in the event of power failure
Stand-alone control of up to 14 I/O points using proven algorithms
Native BACnet MS/TP communications
System Benefits
Fully plug-and-play with the Carrier i-Vu Building Automation System
Supports demand limiting for maximum energy savings
Specifications
| BACNet Support | Advanced application controller (B-AAC), as defined in BACNet 135-2001 Annex L |
| Communication Ports | BACnet port: EIA-485 port for BACnet MS/TP communications (baud rates is DIP switch selectable) Local Access port: For system start-up and troubleshooting (115.2 kbps) Rnet port: For connecting Carrier communicating room sensors and Carrier's touchscreen user interface |
| Inputs | 6 inputs: Configurable for thermistor or dry contact. Inputs 1 and 2 are also configurable for 0-5 VDC. Inputs 7 and 8 are not used. AIs have 10 bit A/D resolution. |
| Outputs | 5 binary outputs: Relay contacts rated at 1A max @ 24 VAC/VDC, configured normally open. 3 analog outputs: Rated at 0-10VDC, 5mA max, with 8 bit D/A resolution using filtered PWM. |
| Protection | Incoming power and network connections are protected by non-replaceable internal solidstate polyswitches that reset themselves when the condition that causes a fault returns to normal. The power, network, input, and output connections are also protected against voltage transient and surge events.. |
| Real Time Clock | Battery-backed real time clock keeps track of time in event of power failure |
| Battery | 10-year Lithium CR2032 battery provides a minimum of 10,000 hours of trend data & time retention during power outages. |
| Status Indicators | LED status indicators for communications, run status, error, power, and all digital outputs. |
| Controller Addressing | Rotary DIP switches set BACnet MS/TP MAC address of controller. |
| Listed By | UL-916 (PAZX), cUL-916 (PAZX7), FCC Part 15-Subpart B-Class A, CE EN50082-1997 |
| Environmental Operating Range | Operating: 0° to 140°F (-18° to 54°C), 10-90% relative humidity, non-condensing Storage: -24°F to 140°F (-30° to 60°C), 10-90% relative humidity, non-condensing |
| Power Requirements | 24VAC +/- 10%, 50-60Hz 18VA power consumption 26VDC (25V min, 30V max Single Class 2 source only, 100VA or less |
Documents
Brochure
VVT Zoning System Brochure Low Resolution 1/21
VVT Zoning System Brochure High Resolution 1/21
VVT Zoning System Brochure Print Version 1/21
Case Study
evolv1 building
Controls
i-Vu Open General Purpose Controller Guide Specification
Installation
AppController Installation and Startup Guide
i-Vu Open WSHP for AppController Installation and Start-Up Guide
Fan Coil Integration Guide
Open Controller Network Wiring Guide
Air Source Interface for AppController Installation and Startup Guide
i-Vu Open Unit Ventilator V2 for AppController Installation and Start-Up Guide
Fan Coil for AppController Installation and Start-up Guide
GSLC for AppController Installation and Start-up Guide
Product Data
i-Vu Open AppController Product Data Sheet