Technical Specifications
Parameters and Compatibility
| Type | Passive CA |
| Updated Sensors | O₂ and CO₂ |
| CO₂ setpoint range | 1%–19% (±0.5%) |
| O₂ safety threshold | 3% |
| Platforms | Factory-fit OptimaLINE and PrimeLINE |
| Telematics | Lynx Fleet |
| Datalogging | O₂, CO₂, Humidity |
| Trip Length | up to 20 days |
Choosing the Right Controlled Atmosphere Solution
| Feature | SimplyFRESH | EverFRESH |
| Type | Passive CA | Active CA |
| Ideal voyage | Shorter (<20 days) | Extended (up to 5 weeks) |
| CO₂ control | ✓ | ✓ |
| O₂ pulldown | — | ✓ Using nitrogen |
| O₂ measurement | ✓ | ✓ |
| O₂ setpoint | — | ✓ |
SimplyFRESH and EverFRESH® serve different needs. Choose SimplyFRESH for cost-efficient protection on shorter routes; choose EverFRESH when extended voyages require full active atmosphere control.