WeatherMaker® Single-Packaged Rooftop Units with EcoBlue™ Technology
50FCQ
Heat Pump Units with Puron® (R-410A) Refrigerant
3 to 6 Nominal Tons
Patented, new EcoBlue™ Technology was designed to improve performance and efficiency while decreasing maintenance and installation costs. The industry’s first beltless direct-drive vane axial fan for rooftop units is just one of many technological advances that prove that not all rooftop units are created equal. Other enhancements include a new control board and coil technology, permanently lubricated motor bearings, tool-less filter access doors and more – all available on this multi efficiency offering.






Performance Features
- Meets and exceeds ASHRAE 90.1 energy efficiency levels
- New unit control board with intuitive quick fan speed adjustment
- New direct drive - EcoBlue™ Technology indoor fan system uses Vane Axial fan design & electronically commutated motor
- Single-stage cooling capacity 04-06 models, two-stage on 07 models
- SEERs to 14.3, IEER of 15.0
- HSPF to 8.2 and COP’s to 3.6
- Standard Cooling operating range up to 115 °F (46°C) and down to 40°F (4°C), lower temperature operation possible with low ambient kits
- Innovative corrosive-resistant composite condensate pan in accordance with ASHRAE 62 Standard, sloping design; side or center drain
- Proven high performance round copper tube and aluminum fin coil designs
- Pre-painted exterior panels and primer-coated interior panels tested to 500 hours salt spray protection
- 04 to 06 models use fixed refrigerant metering device and 07 models use a TXV
Maintenance Features
- New unit control board facilitating simple safety circuit troubleshooting and simplified control box arrangement as well as easy intuitive fan speed adjustment
- Access panels with easy grip handles
- Innovative, easy starting, no-strip screw feature on unit access panels
- Tool-less filter access door
- Optional hinged access panels also available
- NEW Direct Drive – EcoBlue™ Technology Indoor fan system uses Vane Axial fan design and electronically commutated motor with beltless design
- Two-inch disposable return air filters
Installation Features
- Same footprint as prior Carrier models for that original fit; reduces installation costs and time
- Field convertible from vertical to horizontal airflow configuration
- Provisions for thru-the-bottom power entry capability as standard
- Single point electrical and controls connections
- Full perimeter base rail with built-in rigging adapters and fork truck slots
Reliability Features
- Scroll compressors with internal line-break overload protection
- 24-volt control circuit protected with resettable circuit breaker
- Permanently lubricated direct-drive ECM evaporator-fan motor
- Totally enclosed condenser motors with permanently lubricated bearings
- Low pressure and high-pressure switch protection
- Precisely sizes suction line accumulator
- Proven Time/Temperature defrost logo and control board
Standard Limited Warranty
- 5 years electric heaters
- 5 years parts only compressor
- 3 year SystemVu™ controller
- One year parts only on all other parts
- Additional extended warranty packages available
Factory-Installed Options
- Temperature Sensing EconoMi$er with built-in relief
- Enthalpy Sensing EconoMi$er with built-in relief
- Multiple Electric Heat Sizes & Voltages
- Return Air Smoke Detector
- Supply Air Smoke Detector
- CO2 Sensor
- Condensate Overflow Protection
- Multiple Static Fan Capabilities
- Phase Monitor/Protection
- Thru-The-Base Utility Connections
- Louvered Hail Guards
- Non-Fused Disconnect Switch
- MERV-8 Return Air Filters
- Hinged Access Panels
- Unpowered Convenience Outlet
- Powered Convenience Outlet
- Coated Coils:
- Pre-Coat
- E-Coat
- Copper/Copper
- Electrical Mechanical Controls
- Intelligent SystemVu™ Integrated Communicating Controls
- Large full text – multi line display
- USB Flash Port for data transfer
- Built in i-Vu®, CCN and BACnet®
- Refrigerant pressure from display
- Quick LED Status – Run, Alert, Fault
- Conventional stat or sensor capabilities
- Historical component runtime and starts
- Supply Air Tempering
- Equipment / System Touch Compatibility
- Demand Limiting and ZS Sensor Compatibility
- RTU-Open Communicating Controls
- Extended Warranty Protection Plans
- Financing Available
Heat Pump Models (50FCQ)
Nominal Cooling Ton Size | Cooling Stages | AHRI Efficiency (SEER) EER | Dimensions (in) LxWxH | At 47°F | At 17°F | Approx. Unit Weight (lbs) | ||
---|---|---|---|---|---|---|---|---|
Heating Capacity (Btuh) | HSPF COP | Heating Capacity (Btuh) | HSPF COP | |||||
3 | 1 | (14.3) | 74 x 47 x 33 | 34000 | (8.2) | 17000 | n/a | 467 |
4 | 1 | (14.3) | 74 x 47 x 33 | 46600 | (8.2) | 23600 | n/a | 473 |
5 | 1 | (14.3) | 74 x 47 x 41
|
56500 | (8.2) | 30000 | n/a | 584 |
6 | 2 | 15.0 | 74 x 47 x 41 | 64500 | 3.60 | 35000 | 2.4 | 589 |
AHRI = Air-Conditioning, Heating & Refrigeration Institute
ASHRAE = American Society of Heating, Refrigerating and Air Conditioning, Inc.
IEER = Integrated Energy Efficiency Ratio
SEER = Seasonal Energy Efficiency Ratio
COP = Coefficient of Performance
HSPF = Heating Seasonal Performance Factor
NOTES
1. Rated and certified under ARI Standard 210/240 3-5 ton or 340/360 6-ton, as appropriate.
2. Ratings are based on:
» Cooling Standard: 80°F (27°C) db, 67°F (19°C) wb indoor air temp and 95°F (35°C) db outdoor air temp.
3. All 50FCQ units comply with ASHRAE 90.1-2016 Energy Standard for minimum SEER and EER requirements.
4. 50FCQ units comply with US Energy Policy Act (2005). To evaluate code compliance requirements, refer to state and local codes or visit the following website: http://bcap-energy.org
Performance Features
- Meets and exceeds ASHRAE 90.1 energy efficiency levels
- New unit control board with intuitive quick fan speed adjustment
- New direct drive - EcoBlue™ Technology indoor fan system uses Vane Axial fan design & electronically commutated motor
- Single-stage cooling capacity 04-06 models, two-stage on 07 models
- SEERs to 14.3, IEER of 15.0
- HSPF to 8.2 and COP’s to 3.6
- Standard Cooling operating range up to 115 °F (46°C) and down to 40°F (4°C), lower temperature operation possible with low ambient kits
- Innovative corrosive-resistant composite condensate pan in accordance with ASHRAE 62 Standard, sloping design; side or center drain
- Proven high performance round copper tube and aluminum fin coil designs
- Pre-painted exterior panels and primer-coated interior panels tested to 500 hours salt spray protection
- 04 to 06 models use fixed refrigerant metering device and 07 models use a TXV
Maintenance Features
- New unit control board facilitating simple safety circuit troubleshooting and simplified control box arrangement as well as easy intuitive fan speed adjustment
- Access panels with easy grip handles
- Innovative, easy starting, no-strip screw feature on unit access panels
- Tool-less filter access door
- Optional hinged access panels also available
- NEW Direct Drive – EcoBlue™ Technology Indoor fan system uses Vane Axial fan design and electronically commutated motor with beltless design
- Two-inch disposable return air filters
Installation Features
- Same footprint as prior Carrier models for that original fit; reduces installation costs and time
- Field convertible from vertical to horizontal airflow configuration
- Provisions for thru-the-bottom power entry capability as standard
- Single point electrical and controls connections
- Full perimeter base rail with built-in rigging adapters and fork truck slots
Reliability Features
- Scroll compressors with internal line-break overload protection
- 24-volt control circuit protected with resettable circuit breaker
- Permanently lubricated direct-drive ECM evaporator-fan motor
- Totally enclosed condenser motors with permanently lubricated bearings
- Low pressure and high-pressure switch protection
- Precisely sizes suction line accumulator
- Proven Time/Temperature defrost logo and control board
Standard Limited Warranty
- 5 years electric heaters
- 5 years parts only compressor
- 3 year SystemVu™ controller
- One year parts only on all other parts
- Additional extended warranty packages available
Factory-Installed Options
- Temperature Sensing EconoMi$er with built-in relief
- Enthalpy Sensing EconoMi$er with built-in relief
- Multiple Electric Heat Sizes & Voltages
- Return Air Smoke Detector
- Supply Air Smoke Detector
- CO2 Sensor
- Condensate Overflow Protection
- Multiple Static Fan Capabilities
- Phase Monitor/Protection
- Thru-The-Base Utility Connections
- Louvered Hail Guards
- Non-Fused Disconnect Switch
- MERV-8 Return Air Filters
- Hinged Access Panels
- Unpowered Convenience Outlet
- Powered Convenience Outlet
- Coated Coils:
- Pre-Coat
- E-Coat
- Copper/Copper
- Electrical Mechanical Controls
- Intelligent SystemVu™ Integrated Communicating Controls
- Large full text – multi line display
- USB Flash Port for data transfer
- Built in i-Vu®, CCN and BACnet®
- Refrigerant pressure from display
- Quick LED Status – Run, Alert, Fault
- Conventional stat or sensor capabilities
- Historical component runtime and starts
- Supply Air Tempering
- Equipment / System Touch Compatibility
- Demand Limiting and ZS Sensor Compatibility
- RTU-Open Communicating Controls
- Extended Warranty Protection Plans
- Financing Available
Heat Pump Models (50FCQ)
Nominal Cooling Ton Size | Cooling Stages | AHRI Efficiency (SEER) EER | Dimensions (in) LxWxH | At 47°F | At 17°F | Approx. Unit Weight (lbs) | ||
---|---|---|---|---|---|---|---|---|
Heating Capacity (Btuh) | HSPF COP | Heating Capacity (Btuh) | HSPF COP | |||||
3 | 1 | (14.3) | 74 x 47 x 33 | 34000 | (8.2) | 17000 | n/a | 467 |
4 | 1 | (14.3) | 74 x 47 x 33 | 46600 | (8.2) | 23600 | n/a | 473 |
5 | 1 | (14.3) | 74 x 47 x 41
|
56500 | (8.2) | 30000 | n/a | 584 |
6 | 2 | 15.0 | 74 x 47 x 41 | 64500 | 3.60 | 35000 | 2.4 | 589 |
AHRI = Air-Conditioning, Heating & Refrigeration Institute
ASHRAE = American Society of Heating, Refrigerating and Air Conditioning, Inc.
IEER = Integrated Energy Efficiency Ratio
SEER = Seasonal Energy Efficiency Ratio
COP = Coefficient of Performance
HSPF = Heating Seasonal Performance Factor
NOTES
1. Rated and certified under ARI Standard 210/240 3-5 ton or 340/360 6-ton, as appropriate.
2. Ratings are based on:
» Cooling Standard: 80°F (27°C) db, 67°F (19°C) wb indoor air temp and 95°F (35°C) db outdoor air temp.
3. All 50FCQ units comply with ASHRAE 90.1-2016 Energy Standard for minimum SEER and EER requirements.
4. 50FCQ units comply with US Energy Policy Act (2005). To evaluate code compliance requirements, refer to state and local codes or visit the following website: http://bcap-energy.org


