Louvered Hail Guard Accessory for 48/50V 27-60 Ton Units
WeatherMaster® 50V Applied Rooftop Unit
Type
Electric Heat/Hydronic Heat/Electric CoolingRefrigerant
R-454BCapacity Range
27.5 - 100 TonsEfficiency (EER/IEER)
10.5, 16.6Compact Chassis (fits select competitor curbs, shortest chassis)
Standard Chassis (fits select Carrier P/Z series curbs, highest filtration and fan static capability)
Low global warming potential (GWP) Puron Advance™ refrigerant (R454B)
Refrigerant leak detection system with dissipation control
Standard capacity variable speed scroll compressor
Electronic expansion valves (EXV) metering devices ensure reliable performance across a wide operating envelope.
Single refrigerant circuit with fully active Al/Cu evaporator coil on 27.5-40 tons
Dual refrigerant circuit with intertwined Al/Cu evaporator coil on 50-100 tons
Variable speed condenser fans with Greenspeed intelligence allow for optimized part load performance and allow mechanical cooling down to -10°F (-23.3°C) under appropriate conditions.
Galvanized steel condensate drain pan
Large MCHX condenser coils for reduced refrigerant charge and efficient operation
Direct drive indoor fan array with standard, medium or high static electronically commutated motors (ECM)
Multiple indoor fan control methods, including SAV, CV, SZ-VAV, multi-zone VAV duct pressure, or 3rd party input
Multiple pre filter options to help with indoor air quality
Pre-painted exterior panels and primer-coated interior panels tested to 500 hours salt spray protection
Carrier SmartVu™ controls with 7” touchscreen display
10kA short circuit current rating (SCCR)
Meets or exceed the EER & IEER requirements of ASHRAE Standard 90.1, DOE 2023, and certified (sizes 28-70) or rated in accordance (sizes 74-98) with AHRI Standard 340/360 (sizes 28-70)
UL listed for compliance with UL Standard 60335-2-40
Units tested in Carrier and third-party labs to verify performance and efficiency.
SmartVu™ controller monitors, records, and reports unit performance. Also provides diagnostics and alarms of abnormal unit operation.
Integrated variable speed compressor protection
Liquid line filter driers and crankcase heaters standard on all models
Refrigerant system performance monitoring
Cabinet made of pre-painted, galvanized steel, which meets ASTM B117 salt spray resistance test
Condenser-fan motors are totally enclosed
Hinged access doors with latches to access maintainable components, such as pre-filters, electric/hydronic heat, and controls.
Components, such as electronic expansion valves (EXVs) and condenser fans, are accessible through large access panels for service
SmartVu™ diagnostics include refrigerant pressure sensors and maintenance reminders
Condensing and suction pressure sensors to monitor the refrigerant circuit
Fan shutoff interlock on indoor fan access panel to prevent injury to service personnel if the door opens while the fans are running
SmartVu™ controls are factory installed and configured to match unit configuration to help reduce setup time.
Shipped with R-454B refrigerant charge
Factory installed A2L leak detection and mitigation reduces installation and commissioning time
Heavy duty base rail with lifting lugs for easy rigging
Single-point electrical connection
Provisions for thru-the-bottom power and control wiring
Factory-installed outside air hoods
3-years parts only on microchannel condenser coil
5-year parts on ultra-low leak economizer
One year parts on all other non-consumable parts
Low, medium or high electric heat with two-stage control
Low, medium or high electric heat with modulating silicon rectifier (SCR) control
High capacity variable speed scroll compressor
Low sound package includes shrouded, low sound condenser fans, low RPM motors, and sound blankets
High efficiency, low sound package for reduced radiant sound during mechanical cooling operation and improved cooling efficiency with up to 21.2 IEER
Humidi-MiZer® adaptive dehumidification system with modulating control
Standard or compact chassis
Extended standard chassis
Plenum section
Humidity and enthalpy sensing (OARH & RARH) for dehumidification or free cooling control
Return air CO2 sensor for ventilation control
Outdoor airflow measuring
E-Coat MCHX Condenser
E-Coat Al/Cu Evaporator
Stainless steel drain pan
Louvered hail guard (sizes 28-60)
Security grille (sizes 70-100)
Ultra-low leak economizer for ventilation and free cooling
Barometric relief
Standard, low and medium static power exhaust fan
Modulating building pressure control
Condensate overflow switch
Pre-filter status switch with access door retainers
Service pack with compressor isolation valves, replaceable core filter drier
Return air smoke detector
Chicago refrigerant relief valve
Non-fused disconnect
Powered or un-powered convenience outlet
Phase monitor
High short circuit current rating (65kA for 208/230/460V, 25kA for 575V)
2” pre-evaporator filter rack with 2” MERV 8 filters
4” pre-evaporator filter rack with 4” MERV 8 or 13 filters
2” MERV 8 + 4” MERV 13 pre-evaporator filters
2” MERV 8 + 12” MERV 14 bag pre-evaporator filters
2” MERV 8 + 12” MERV 15 cartridge pre-evaporator filters
Factory-installed UV-C fixtures with wiring, disconnect switch, door interlocks, and access door with UV safe view port
Return air CO2 sensor
CO2 space sensor
CO2 aspirator box
UV-C emitters
Return air CO2 sensor
Smoke detector
Dirty filter switch
Non-communicating space sensors, including temperature and humidity
Communicating space sensors, including temperature and humidity
Space CO2 sensors
Carrier i-Vu Equipment Touch display
Thermostats
14-inch roof curb
Compressor sound blankets
Actuated hot water valves
Accessory and Kit Data
Louvered Hail Guard Accessory for 48/50V 27-60 Ton Units
Curb Centering Kit for Compact Chassis 48/50V 28-50, 27.5-50 Ton
RNET Harness Accessory for 48/50K 20-60 Tons and 48/50V 27.5-100 Tons, P/N CRRNETPH001A00
Ultraviolet Lamp Accessory for 48/50K, 48/50V
Accessory Roof Curbs for 48/50V Package Rooftop Units
Compressor Sound Blanket Accessory for 48/50V , P/N: CRSOUBLN040A00 - CRSOUBLN053A00
Brochure
Light Commercial and Applied Packaged Rooftop Unit Line Card
Humidi-MiZer® Adaptive Dehumidification System
Staged Air Volume (SAV) System for Carrier’s Applied Packaged Rooftop Units
Controls
SmartVu™ Controls Version 2.X for Light Commercial and Applied Rooftop Gas Heat/Electric Cooling and Electric Heat/Electric Cooling Units with PIC 6.0 Hardware, Integration Guide
SmartVu™ Controls Version 3.X for Applied Rooftop Gas Heat/Electric Cooling and Electric Heat/Electric Cooling Units with PIC 6.1 Hardware
Guide Specifications
50V Guide Specifications, 27.5 to 35 Nominal Tons
50V Guide Specifications, 27.5 to 100 Nominal Tons
Installation
WeatherMaster® 50V 28-98 Electric Cooling with Optional Heating Applied Rooftop Units with Puron Advance Refrigerant (R-454B) and Carrier SmartVu™ Controls
Product Data
48/50V 27-35 WeatherMaster® Applied Rooftop Units 27.5 to 35 Nominal Tons (R-410A)
48/50V 28-98 WeatherMaster® Applied Rooftop Units 27.5 to 100 Nominal Tons (R-454B)
REVIT and 3D DRW Files
50V No Heat or Electric Heat Applied Rooftop Units, Sizes 27-35, Standard Chassis, Family REVIT Files
50V No Heat or Electric Heat Applied Rooftop Units, Sizes 27-35, Standard Chassis with Extended Section, Family REVIT Files
50V No Heat or Electric Heat Applied Rooftop Units, Sizes 27-35, Standard Chassis with Plenum Section, Family REVIT Files
50V No Heat or Electric Heat Applied Rooftop Units, Sizes 27-35, Standard Chassis with Extended Section and Plenum Section, Family REVIT Files
50V No Heat or Electric Heat Applied Rooftop Units, Sizes 27-35, Compact Chassis, Family REVIT Files
50V Hydronic Heat Applied Rooftop Units, Sizes 27-35, Standard Chassis, Family REVIT Files
50V Hydronic Heat Applied Rooftop Units, Sizes 27-35, Standard Chassis with Extended Section, Family REVIT Files
50V Hydronic Heat Applied Rooftop Units, Sizes 27-35, Standard Chassis with Plenum Section, Family REVIT Files
50V Hydronic Heat Applied Rooftop Units, Sizes 27-35, Standard Chassis with Extended Section and Plenum Section, Family REVIT Files
50V Hydronic Heat Applied Rooftop Units, Sizes 27-35, Compact Chassis, Family REVIT Files
48/50V Family REVIT Files
50V RTU Extended Standard Chassis, 54-60T Family REVIT Files
50V RTU Extended Standard Chassis,70T Family REVIT Files
50V RTU Extended Standard Chassis, 75T Family REVIT Files
50V RTU Extended Standard Chassis, Plenum 54-60T Family REVIT Files
50V RTU Extended Standard Chassis, Plenum, 70T Family REVIT Files
50V RTU Standard Chassis, 54-60T Family REVIT Files
50V RTU Standard Chassis, 70T Family REVIT Files
50V RTU Standard Chassis, 75T Family REVIT Files
50V RTU Standard Chassis, Plenum, 54-60T Family REVIT Files
50V RTU Standard Chassis, Plenum, 70T Family REVIT Files
50V RTU Standard Chassis, 27-35T, All Heat/No Heat, Plenum REVIT Files
50V RTU Standard Chassis, Extended Section, 27-35T, All Heat/No Heat REVIT Files
50V RTU Standard Chassis, Extended Section, 27-35T, All Heat/No Heat, Plenum REVIT Files
50V RTU Standard Chassis, 27-35T, All Heat/No Heat REVIT Files
50V RTU Compact Chassis, 27-35T, All Heat/No Heat REVIT Files
50V RTU Standard/Extended Chassis, 90-100T, Hydronic REVIT Files
50V RTU Standard Chassis, 27-35T, Hydronic, Plenum REVIT Files
50V RTU Standard Chassis/Extended Section, 27-35T, Hydronic REVIT Files
50V RTU Standard Chassis/Extended Section, 27-35T, Hydronic, Plenum REVIT Files
50V RTU Standard Chassis, 90-100T, Hydronic REVIT Files
50V RTU Standard Chassis, 27-35T, Hydronic REVIT Files
50V RTU Compact Chassis, 27-35T, Hydronic REVIT Files
Warranty Card
Limited Warranty - 50K and 50V Commercial Rooftop Equipment