WeatherMaster® Puron Advance™ Single-Packaged Heat Pump Rooftop Units with EcoBlue™ Technology 50GEQ

WeatherMaster® 50GEQ Single-Packaged Heat Pump Rooftop Unit with Puron Advance™ & EcoBlue™ Technology

Technical Specifications

At a glance

Type

Heat Pump

Refrigerant

R-454B

Capacity Range

3 - 25 Tons

Efficiency (SEER/IEER)

17.6

Features

Performance Features
 

Puron Advance (R-454B) refrigerant meets and exceeds EPA’s new Low GWP requirements

New unit control board with intuitive quick fan speed adjustment 

NEW – UL 60335-2-40 Certified A2L leak detection and dissipation system factory installed standard 

Direct Drive EcoBlue™ Technology indoor fan system uses Vane Axial fan design & electronically commutated motor 

Two-stage cooling capacity control on all models and Three-stage on 07-28 models

SEER2s up to 16.0, HSPF2 up to 7.2 

IEER up to 17.6, COP up to 3.7 

Cooling operating range up to 125°F (52°C) and down to 35°F (1.6°C)

Innovative corrosive-resistant composite condensate pan in accordance with ASHRAE 62 Standard, sloping design; side or center drain 

Pre-painted exterior panels and primer-coated interior panels tested to 500 hours salt spray protection 

Units meet and exceed ASHRAE 90.1 energy efficiency levels.

 

Maintenance Features
 

New unit control board facilitating simple safety circuit troubleshooting and simplified control box arrangement as well as easy intuitive fan speed adjustment 

Access panels with easy grip handles 

Innovative, easy starting, no-strip screw feature on unit access panels 

Tool-less filter access door 

Optional hinged access panels also available 

NEW Direct Drive – EcoBlue™ Technology Indoor fan system uses Vane Axial fan design and electronically commutated motor with beltless design 

Two-inch disposable return air filters

 

Installation Features
 

Same footprint as prior Carrier models for that original fit; reduces installation costs and time

Field convertible from vertical to horizontal airflow configuration

Provisions for thru-the-bottom power entry capability as standard

Single point electric, and controls connections

Full perimeter base rail with built-in rigging adapters and fork truck slots

 

Reliability Features
 

A2L leak detection and dissipation system standard

Scroll compressors with internal line-break overload protection

24-volt control circuit protected with resettable circuit breaker

Permanently lubricated direct-drive ECM evaporator-fan motor

Totally enclosed condenser motors with permanently lubricated bearings

Low pressure and high-pressure switch protection

 

Standard Limited Warranty
 

5 years electric heaters

5 years parts only compressor

3 year SystemVu™ controller

One year parts only on all other parts

Additional extended warranty packages available

Options

Factory-Installed Options

 

Temperature Sensing Economizer with barometric relief

Enthalpy Sensing Economizer with barometric relief

Return Air Smoke Detector

Supply Air Smoke Detector

CO₂ Sensor

Condensate Overflow Protection

Multiple Static Fan Capabilities

Phase Monitor/Protection

Thru-The-Base Utility Connections

Louvered Hail Guards

Non-Fused Disconnect Switch

HACR breaker

Foil face insulation

HSCCR

4" MERV-13 Filters

Hinged Access Panels

Unpowered Convenience Outlet

Powered Convenience Outlet

Coated Coils: Pre-Coat, E-Coat, Copper/Copper

Electrical Mechanical Controls

SystemVu™ Integrated Communicating Controls

Physical Data

Heat Pump (50GEQ)

Nominal Cooling Ton SizeCooling StagesAHRI Efficiency (SEER2) IEERDimensions (in) LxWxHHeating Capacity (Btuh) @ 47°F(HSPF) COPHeating Capacity (Btuh) @ 17°F(HSPF) COPApprox Unit Weight
(lbs)
32(16.0)74x46x41330003.80172002.30567
42(16.0)74x46x41450003.70255002.40594
52(16.0)74x46x41540003.70300002.30596
6217.4 (2-stage)
21.0 (3-stage)
88x59x49670003.70360002.30805
7.5217.4 (2-stage)
19.6 (3-stage)
88x59x49870003.60450002.30812
8.5217.4 (2-stage)
19.2 (3-stage)
88x59x49940003.50520002.35955
10216.8 (2-stage)
18.5 (3-stage)
111x63x571080003.50600002.351250
15217.0 (2-stage)
19.0 (3-stage)
141x86x491660003.50960002.301627
20216.4 (2-stage)
18.5 (3-stage)
157x86x57232000 (2-stage)
244000 (3-stage)
3.40134000 (2-stage)
148000 (3-stage)
2.252057
25215.5 (2-stage)
17.5 (3-stage)
157x86x573000003.401720002.202125

AHRI = Air-Conditioning, Heating & Refrigeration Institute
ASHRAE = American Society of Heating, Refrigerating and Air Conditioning, Inc.
IEER = Integrated Energy Efficiency Ratio
SEER2 = Seasonal Energy Efficiency Ratio 2
HSPF2 = Heating Seasonal Performance Factor 2
COP = Coefficient of Performance

NOTES

  1. Rated and certified under ARI Standard 210/240 3-5 ton or 340/360 6+ ton, as appropriate
  2. Ratings are based on: 
    • Cooling Standard: 80°F (27°C) db, 67°F (19°C) wb indoor air temp and 95°F (35°C) db outdoor air temp.
  3. 50GEQ units generally comply with ASHRAE 90.1-2016 Energy Standard. Please review size specific data for compliance.
  4. 50GEQ units comply with US Energy Policy Act (2005).

Documents

Accessory and Kit Data

Electric Heater and Single Point Box Accessory for Electric Cooling Small Rooftop Units, Select 3 to 6 Tons CRHEATER323A00-341A00, CRSINGLE037A00-041A00,060A00-063A00

Heater Accessory for Single Package Rooftop Units Select 17.5 to 27.5 Tons P/N CRHEATER454A00-CRHEATER471A00

Electric Heater and Single Point Box Accessory for Electric Cooling Select 6 to 15 Tons, P/N CRHEATER410A-428A, 451A-453A, CRSINGLE 042A00-045A00, 47A00, 049A00-053A00, 064A00-073A00

Vertical Power Exhaust Accessory for Gas Heating/Electric Cooling, Electric Cooling, and Heat Pump Rooftop Units, 3 to 15 Tons, CRPWREXH021A01, CRPWREXH022A01, CRPWREXH023A01, CRPWREXH030A01, CRPWREXH080A00, CRPWREXH081A00

CRTRVUKT001A00 TruVu Controller Kit for Rooftop Units 48/50FE*04-16, 50FEQ04-14, 48/50GE*04-14, 50GEQ04-12, 48/50FC*04-16, 50FCQ04-14, 48/50GC*04-14 and 50GCQ04-12, 3 to 15 Tons

CRTRVUKT002A00 TruVu Controller Kit for Rooftop Units 48/50FE*20-30, 50FEQ17-28, 48/50GE*17-28, 50GEQ17-28, 48/50FC*20-30, 50FCQ17-28, 48/50GC*17-28, and 50GCQ17-28, 15 to 27.5 Tons

Brochure

Light Commercial and Applied Packaged Rooftop Unit Line Card

Controls

50FEQ 04-28, 50GEQ 04-28, 48QE 04-28 Single Package Rooftop Heat Pump and Hybrid Heat Units with SystemVu™ Controls Version 4.X and Puron Advance™(R-454B) Refrigerant Controls, Start-Up, Operation and Troubleshooting

Installation

50GEQ*12 WeatherMaster® Single Package Rooftop Heat Pump with Puron Advance™ Refrigerant and EcoBlue™ Fan Technology

50GEQ*07-09 WeatherMaster® Single Package Rooftop Heat Pump with Puron Advance™ Refrigerant and EcoBlue™ Fan Technology

50GEQ*17-28 WeatherMaster® Single Package Rooftop Heat Pump with Puron Advance™ Refrigerant and EcoBlue™ Fan Technology

50GEQ*04-06 WeatherMaster® Single Package Rooftop Heat Pump with Puron Advance™ Refrigerant

Maintenance

50GEQ*04-06 Single Package Rooftop Heat Pump with Puron Advance™ (R-454B) Refrigerant

50GEQ*017-28 Single Package Rooftop Heat Pump with Puron Advance™ (R-454B) Refrigerant and EcoBlue™ Fan Technology

Product Data

50GEQ*04-06 WeatherMaster® Single-Packaged Heat Pump with Optional Electric Heat and Puron Advance™ Refrigerant (R-454B), 3 to 5 Nominal Tons

50GEQ*07-12 WeatherMaster® Single-Packaged Heat Pump with Optional Electric Heat and Puron Advance™ Refrigerant (R-454B), 6 to10 Nominal Tons

50GEQ*17-28 WeatherMaster® Single-Packaged Heat Pump with Optional Electric Heat and Puron Advance™ Refrigerant (R-454B), 15 to 25 Nominal Tons

REVIT and 3D DRW Files

50GEQ Electric, 6-7.5T REVIT Files

50GEQ Electric, 8.5T REVIT Files

50GEQ Electric, 10T REVIT Files

50GEQ Electric, 3-5T REVIT Files

50GEQ Electric, 15T REVIT Files

50GEQ Electric, 20-25T REVIT Files

Warranty Card

Limited Warranty for Light Commercial Equipment

Need assistance? Ask Carrier.

Get in touch