AquaSnap® Indoor Water-Cooled/Condenserless Liquid Chiller
30MP

with Puron® Refrigerant (R-410A)

16 to 71 Nominal Tons

30MPA - Condenserless Chiller
30MPW - Packaged Chiller

AquaSnap® 30MP packaged liquid and condenserless chillers feature a compact modular design that makes them ideal for easy replacement, retrofit, or new construction applications.

Water-cooled chillers within the scope of the AHRI WCCL certification program are certified in accordance with the AHRI Water-Cooled Water-Chilling and Heat Pump Water-Heating Packages Certification Program, which is based on AHRI Standard 550/590 (I-P) and AHRI Standard 551/591 (SI). Certified units may be found in the AHRI Directory at www.ahridirectory.org. Condenserless versions of these units and 50 Hz. units below 200 Tons are not certified under the AHRI certification program.


carrier-AHRI-550-590-551-591_WCCL
carrier-iso-9001
carrier-intertek-ETL-listed-C-US

Performance Features

  • ASHRAE 90.1 compliant
  • ComfortLink™ microprocessor-based controls
  • High-efficiency scroll compressor
  • Quiet, reliable operation
  • Easy-to-use controls
  • Energy management module minimizes chiller energy consumption (factory-installed option or field-installed accessory)
  • Scrolling marquee display shows operating parameters in plain language
  • Heat recovery capability up to 140°F (60°C)
  • Modular capability to install up to eight (8) modules together to reach capacities up to 560 tons

Reliability Features

  • Thermostatic expansion valves (016-045 models)
  • Electronic expansion valves (050-071 models)
  • Hermetic-type filter driers
  • Loss of refrigerant charge protection
  • Low control voltage (to unit) protection
  • Thermal overload protection
  • Pressure overload
  • Electrical overload through the use of definite-purpose contactors and calibrated, ambient compensated, magnetic trip circuit breakers
  • Standard 60 Hz unit listed with ETL and ETL, Canada, and built in accordance with ASME requirements

Maintenance Features

  • Over 15 diagnostic functions
  • Moisture indicating sight glasses

Installation Features

  • Single point electrical connection
  • Shipped with R-410A (30MPW ) or nitrogen (30MPA) holding charge
  • Fits through standard 36-in. doorway
  • Factory-assembled and shipped with complete internal piping and wiring and essential controls and protective devices
  • Control power transformer
  • Dual circuit, single module (32-ton module)

Standard Warranty

  • One year parts and labor
  • Extended warranties are available

Factory-Installed Options

  • Unit-mounted, non-fused disconnect
  • Medium temperature brine operation
  • EMM (energy management module)
  • Sound enclosure panels
  • Hot gas bypass
  • Non-fused disconnect
  • Medium temperature brine
  • Mobility package (wheels)
  • Condenserless unit
  • Height adjustment (leveling) kit
  • BACnet Communication
  • Digital scroll compressor (020-045 Models)
  • Water manifold piping
  • Electrical distribution panel with breakers for up to four (4) separate 30MP modules

Field-Installed Accessories

  • EMM (energy management module)
  • Sound enclosure panels>
  • Hot gas bypass
  • Vibration isolators (resilient pads)
  • Vibration isolators (springs)
  • BACnet translator
  • LON (local operating network) translator control
  • Mobility package (wheels)
  • Condenser water temperature sensors
  • Height adjustment (leveling) kit
  • Compressor return gas sensor
  • Bronze Y strainer
  • Navigator™ display module
  • Remote enhanced display
  • Victaulic spacer kit (for water manifold piping)
  • Multi-unit controller
30MP Unit Size Capacity Input Power (kW) Evaporator Flow Evaporator Pressure Drop Condenser Flow Condenser Pressure Drop
Tons kW gpm L/s Ft of Water kPa gpm L/s Ft of Water kPa
016 15.02 52.8 11.3 36.1 2.3 13.9 41.6 45.1 2.8 7.7 23.0
020 20.46 72.1 15.3 49.1 3.1 11.3 33.8 61.4 3.9 13.4 40.1
030 31.31 110.1 23.5 75.1 4.7 14.6 43.7 93.9 5.9 7.9 23.6
032 32.06 112.9 23.8 76.9 4.9 6.6 19.7 96.2 6.1 4.7 14.1
040 39.24 137.9 29.3 94.2 5.9 11.2 33.5 117.7 7.4 13.1 39.1
045 47.02 165.3 35.1 112.8 7.1 13.3 39.7 141.1 8.9 16.6 49.6
050 51.5 180.8 37.8 123.3 7.8 11.6 34.7 152.2 9.7 12.9 38.6
055 58.3 205.0 43.6 140.0 8.8 14.6 43.6 175.0 11.0 16.4 49.0
060 60.9 214.2 45.1 146.0 9.2 14.0 41.8 182.6 11.5 13.6 40.7
065 65.6 230.0 48.6 157.1 9.9 16.0 47.8 196.3 12.4 15.5 46.3
071 72.2 253.6 54.0 172.9 10.9 14.8 44.2 216.2 13.6 18.5 55.3
30MP Unit Size Tons Full Load IPLV
EER IkW/Ton COP IkW/Ton COP
016 15.02 16.0 0.750 4.69 0.572 6.15
020 20.46 16.0 0.750 4.69 0.550 6.39
030 31.31 16.0 0.750 4.69 0.581 6.05
032 32.06 16.2 0.742 4.74 0.600 5.86
040 39.24 16.1 0.746 4.71 0.559 6.29
045 47.02 16.1 0.747 4.71 0.578 6.09
050  51.5 16.3 0.735 4.79 0.472 7.45
055  58.3 16.1 0.748 4.70 0.464 7.58
060  60.9 16.2 0.741 4.75 0.474 7.42
065  65.6 16.1 0.743 4.73 0.476 7.39
071  72.2 16.02 0.749 4.70 0.485 7.25

Dimensions (in inches)

Unit Type Length Width Height
30MP (50-71 Capacity) 55.0 32.0 66.3
30MPE Distribution Panel 55.0 32.0 66.3


IPLV: Integrated Part Load Value
AHRI: Air-Conditioning, Heating and Refrigeration Institute
COP: Coefficient of Performance
EER: Energy Efficiency Ratio
IkW: Input Kilowatt

NOTES
1. Rated (60Hz unit) in accordance with AHRI Standard 550/590 at standard rating conditions.
2. Standard rating conditions are as follows:
Cooler Conditions: Leaving Water Temperature: 44°F (6.7°C) Flow: 2.4gpm per ton (0.043 L/s per kW)
Condenser Conditions: Entering Water Temperature: 85°F (29.4°C) Flow: 3.0gpm per ton (0.054 L/s per kW)
Fouling Factor (Cooler): 0.00010 hr x sq ft x °F per Btuh (0.000018m² x K per W)
Fouling Factor (Condenser): 0.00025 hr x sq ft x °F per Btuh (0.000044m² x K per W)
3. IPLV is a single number part load efficiency value calculated from using the efficiency values at 100%, 75%, 50%, and 25% of load when the chiller is operating in AHRI conditions.
4. All data in the above table was generated in Packaged Chiller Builder version 3.39z. Please refer to the most current version of the Packaged Chiller Builder for the most up-to-date data.
5. Contact Carrier for custom ratings.

Performance Features

  • ASHRAE 90.1 compliant
  • ComfortLink™ microprocessor-based controls
  • High-efficiency scroll compressor
  • Quiet, reliable operation
  • Easy-to-use controls
  • Energy management module minimizes chiller energy consumption (factory-installed option or field-installed accessory)
  • Scrolling marquee display shows operating parameters in plain language
  • Heat recovery capability up to 140°F (60°C)
  • Modular capability to install up to eight (8) modules together to reach capacities up to 560 tons

Reliability Features

  • Thermostatic expansion valves (016-045 models)
  • Electronic expansion valves (050-071 models)
  • Hermetic-type filter driers
  • Loss of refrigerant charge protection
  • Low control voltage (to unit) protection
  • Thermal overload protection
  • Pressure overload
  • Electrical overload through the use of definite-purpose contactors and calibrated, ambient compensated, magnetic trip circuit breakers
  • Standard 60 Hz unit listed with ETL and ETL, Canada, and built in accordance with ASME requirements

Maintenance Features

  • Over 15 diagnostic functions
  • Moisture indicating sight glasses

Installation Features

  • Single point electrical connection
  • Shipped with R-410A (30MPW ) or nitrogen (30MPA) holding charge
  • Fits through standard 36-in. doorway
  • Factory-assembled and shipped with complete internal piping and wiring and essential controls and protective devices
  • Control power transformer
  • Dual circuit, single module (32-ton module)

Standard Warranty

  • One year parts and labor
  • Extended warranties are available

Factory-Installed Options

  • Unit-mounted, non-fused disconnect
  • Medium temperature brine operation
  • EMM (energy management module)
  • Sound enclosure panels
  • Hot gas bypass
  • Non-fused disconnect
  • Medium temperature brine
  • Mobility package (wheels)
  • Condenserless unit
  • Height adjustment (leveling) kit
  • BACnet Communication
  • Digital scroll compressor (020-045 Models)
  • Water manifold piping
  • Electrical distribution panel with breakers for up to four (4) separate 30MP modules

Field-Installed Accessories

  • EMM (energy management module)
  • Sound enclosure panels>
  • Hot gas bypass
  • Vibration isolators (resilient pads)
  • Vibration isolators (springs)
  • BACnet translator
  • LON (local operating network) translator control
  • Mobility package (wheels)
  • Condenser water temperature sensors
  • Height adjustment (leveling) kit
  • Compressor return gas sensor
  • Bronze Y strainer
  • Navigator™ display module
  • Remote enhanced display
  • Victaulic spacer kit (for water manifold piping)
  • Multi-unit controller
30MP Unit Size Capacity Input Power (kW) Evaporator Flow Evaporator Pressure Drop Condenser Flow Condenser Pressure Drop
Tons kW gpm L/s Ft of Water kPa gpm L/s Ft of Water kPa
016 15.02 52.8 11.3 36.1 2.3 13.9 41.6 45.1 2.8 7.7 23.0
020 20.46 72.1 15.3 49.1 3.1 11.3 33.8 61.4 3.9 13.4 40.1
030 31.31 110.1 23.5 75.1 4.7 14.6 43.7 93.9 5.9 7.9 23.6
032 32.06 112.9 23.8 76.9 4.9 6.6 19.7 96.2 6.1 4.7 14.1
040 39.24 137.9 29.3 94.2 5.9 11.2 33.5 117.7 7.4 13.1 39.1
045 47.02 165.3 35.1 112.8 7.1 13.3 39.7 141.1 8.9 16.6 49.6
050 51.5 180.8 37.8 123.3 7.8 11.6 34.7 152.2 9.7 12.9 38.6
055 58.3 205.0 43.6 140.0 8.8 14.6 43.6 175.0 11.0 16.4 49.0
060 60.9 214.2 45.1 146.0 9.2 14.0 41.8 182.6 11.5 13.6 40.7
065 65.6 230.0 48.6 157.1 9.9 16.0 47.8 196.3 12.4 15.5 46.3
071 72.2 253.6 54.0 172.9 10.9 14.8 44.2 216.2 13.6 18.5 55.3
30MP Unit Size Tons Full Load IPLV
EER IkW/Ton COP IkW/Ton COP
016 15.02 16.0 0.750 4.69 0.572 6.15
020 20.46 16.0 0.750 4.69 0.550 6.39
030 31.31 16.0 0.750 4.69 0.581 6.05
032 32.06 16.2 0.742 4.74 0.600 5.86
040 39.24 16.1 0.746 4.71 0.559 6.29
045 47.02 16.1 0.747 4.71 0.578 6.09
050  51.5 16.3 0.735 4.79 0.472 7.45
055  58.3 16.1 0.748 4.70 0.464 7.58
060  60.9 16.2 0.741 4.75 0.474 7.42
065  65.6 16.1 0.743 4.73 0.476 7.39
071  72.2 16.02 0.749 4.70 0.485 7.25

Dimensions (in inches)

Unit Type Length Width Height
30MP (50-71 Capacity) 55.0 32.0 66.3
30MPE Distribution Panel 55.0 32.0 66.3


IPLV: Integrated Part Load Value
AHRI: Air-Conditioning, Heating and Refrigeration Institute
COP: Coefficient of Performance
EER: Energy Efficiency Ratio
IkW: Input Kilowatt

NOTES
1. Rated (60Hz unit) in accordance with AHRI Standard 550/590 at standard rating conditions.
2. Standard rating conditions are as follows:
Cooler Conditions: Leaving Water Temperature: 44°F (6.7°C) Flow: 2.4gpm per ton (0.043 L/s per kW)
Condenser Conditions: Entering Water Temperature: 85°F (29.4°C) Flow: 3.0gpm per ton (0.054 L/s per kW)
Fouling Factor (Cooler): 0.00010 hr x sq ft x °F per Btuh (0.000018m² x K per W)
Fouling Factor (Condenser): 0.00025 hr x sq ft x °F per Btuh (0.000044m² x K per W)
3. IPLV is a single number part load efficiency value calculated from using the efficiency values at 100%, 75%, 50%, and 25% of load when the chiller is operating in AHRI conditions.
4. All data in the above table was generated in Packaged Chiller Builder version 3.39z. Please refer to the most current version of the Packaged Chiller Builder for the most up-to-date data.
5. Contact Carrier for custom ratings.