Gemini® 09DP Select Air-Cooled Condenser

Gemini® 09DP Select Air-Cooled Condenser

Technical Specifications

At a glance

Matched Indoor Unit

30HX, 30MP

Indoor Unit Type

Condenserless Chiller

Capacity Range

18 - 130 Tons

Features

Performance Features
 

High short circuit interrupt protection option

Motormaster® V low ambient temperature controller option

Single (09DPS) and multiple (09DPM) split combinations

AeroAcoustic low sound fan option

 
Reliability Features
 

MCHX coil with E-coating option

Galvanized steel cabinet, bonderized and finished with baked enamel, 500-hour salt-spray test

Non-fused disconnect protection option

Security grilles/hail guards option

V-coil design (065-130 models)

UL and UL, Canada approved

 
Installation Features
 

On-the-ground or rooftop installation

Small footprint

Single circuit manifold tubing kit with all 09DPM model

Fork truck lift pockets (018-060) and lifting holes in base rail construction (065-130 models)

Options

Factory-Installed Options
 

Condenser Coil/Low Sound Options: E-Coated MCHX, Low Sound Fan(s)

Ambient/Capacity Control/Interrupt Options: High Short Circuit Current Rating Interrupt, Motormaster V Low Ambient Control

Non-Fused Disconnect

Packaging/Security Options: Bottom Skid, Bottom Skid, Top Crate, Bag, Security Grilles/Hail Guards

 

Field-Installed Accessories
 

Condenser Coil/Low Sound Options: Low Sound Fan(s), Vibration isolation Pads

Ambient/Capacity Control/Interrupt Options: Motormaster V Low Ambient Control

Packaging/Security Options: Security Grilles/Hail Guards, Wind Baffles

Physical Data

ModelTotal Heat of Rejection (Tons)Number of Refrigerant CircuitsTotal Operating Weight (lbs)
09DPS01820.71638
09DPS02033.11719
09DPS03037.71869
09DPM03543.321126
09DPM04054.921204
09DPM05066.421282
09DPM06075.321524
09DPM06585.821622
09DPM075107.621846
09DPM085115.621933
09DPM095129.421933
09DPM115149.422447
09DPM130172.022533

Total heat of rejection based on a 15°F subcooling and 30°F difference between saturated condensing temperature and the outdoor ambient.

 

Dimensions
 
ModelLength (ft-in)Height (ft-in)Width (ft-in)
09DPS0187-55-13-5
09DPS0207-55-13-5
09DPS0307-56-23-5
09DPM0357-95-17-5
09DPM0407-95-17-5
09DPM0507-95-17-5
09DPM0607-95-17-5
09DPM0659-36-17-5
09DPM07512-86-17-5
09DPM08512-86-17-5
09DPM09512-86-17-5
09DPM11516-06-17-5
09DPM13016-06-17-5
 
Electrical Data
 
ModelMCA 208/230MOCPMCA 380MOCPMCA 460MOCPMCA 575MOCP
09DPS0188.3154.9154.1153.315
09DPS02014.9208.8157.4155.915
09DPS03014.9208.8157.4155.915
09DPM03514.9207.4157.4155.915
09DPM040212.52512.71510.7158.515
09DPM05028.13016.62014.01511.015
09DPM06028.13016.62014.01511.115
09DPM06528.13016.62014.01511.115
09DPM07534.74020.52517.32013.715
09DPM08541.34524.42520.62516.315
09DPM09541.34524.42520.62516.315
09DPM11547.94523.92523.92518.920
09DPM13054.56032.23527.23021.525

MCA = Minimum Circuit Amps
MOCP = Maximum Overcurrent Protection

Documents

Accessory and Kit Data

Security Grille/Hail Guard Accessory for 09DPM065-130, 30RAP070-150, 38APD070-130, 38APS065

Motormaster® V Electronic Control Low Ambient Operation Accessory for 09DPS018-030,09DPM035-130

Sound Reduction Kit Accessory for 09DPS018-030, 09DPM035-130, 38APS025-065,38APD025-130 50/60 Hz

Wind Baffle Accessory for 09DPS018-030, 09DPM035-130, 30RAP010-150, 38APD025-130, 38APS025-065

Security Grille/Hail Guard Accessory for 30RAP010-060, 09DPS018-030, 09DPM035-060, 38APS025-050, 38APD025-060

Motormaster® Electronic Control Low Ambient Operation Accessory for 30RAP 010-150, 38APD 025-130, 38APS 025-065, 09DPS/DPM 018-130

Brochure

Special Seismic Compliance Brochure

A World of Comfort 2025 - Brochure

A World of Comfort 2025 - Brochure (Printer Version)

Guide Specifications

09DPM,DPS Guide Specifications, 18 to 130 Nominal Tons (63 to 457 Nominal kW)

Installation

09DPS018-030,09DPM035-130 Air-Cooled Condensing Units, 50/60 Hz

Press Release

Press Release - Carrier Launches Mobile App for Commercial Chillers

Product Data

09DPS018-030,09DPM035-130 Gemini™ Select Air-Cooled Condensers with Puron® Refrigerant (R-410A), 50/60 Hz, 18 to 130 Nominal Tons (63 to 457 Nominal kW)

REVIT and 3D DRW Files

09DP REVIT file. Size 020 Single Circuit with Low Sound Fan.

09DP REVIT file. Size 018 Single Circuit with Low Sound Fan.

09DP REVIT file. Size 065 Multiple Circuit with Low Sound Fan.

09DP REVIT file. Size 130 Multiple Circuit with Low Sound Fan.

09DP REVIT file. Size 085 Multiple Circuit with Low Sound Fan.

09DP REVIT file. Size 130 Multiple Circuit with Standard Fan.

09DP REVIT file. Size 040 Multiple Circuit with Standard Fan.

09DP REVIT file. Size 095 Multiple Circuit with Standard Fan.

09DP REVIT file. Size 018 Single Circuit with Standard Fan.

09DP REVIT file. Size 030 Single Circuit with Low Sound Fan.

09DP REVIT file. Size 050 Multiple Circuit with Standard Fan.

09DP REVIT file. Size 060 Multiple Circuit with Low Sound Fan.

09DP REVIT file. Size 050 Multiple Circuit with Low Sound Fan.

09DP REVIT file. Size 095 Multiple Circuit with Low Sound Fan.

09DP REVIT file. Size 115 Multiple Circuit with Low Sound Fan.

09DP REVIT file. Size 035 Multiple Circuit with Standard Fan.

09DP REVIT file. Size 040 Multiple Circuit with Low Sound Fan.

09DP REVIT file. Size 060 Multiple Circuit with Standard Fan.

09DP REVIT file. Size 065 Multiple Circuit with Standard Fan.

09DP REVIT file. Size 115 Multiple Circuit with Standard Fan.

09DP REVIT file. Size 035 Multiple Circuit with Low Sound Fan.

09DP REVIT file. Size 075 Multiple Circuit with Standard Fan.

09DP REVIT file. Size 075 Multiple Circuit with Low Sound Fan.

09DP REVIT file. Size 030 Single Circuit with Standard Fan.

09DP REVIT file. Size 020 Single Circuit with Standard Fan.

09DP REVIT file. Size 085 Multiple Circuit with Standard Fan.

09DP REVIT file. Size 030 Single Circuit with Standard Fan.

09DP REVIT file. Size 020 Single Circuit with Low Sound Fan.

Warranty Card

Warranty - Standard Product Warranty for Commercial Equipment

Need assistance? Ask Carrier.

Find an expert