Indoor Air Quality CO2 Sensor and Duct-Mounted Aspirator Box for use with EconoMi$er® IV System
WeatherMaker® 50FCQ Single-Packaged Rooftop Unit with EcoBlue™ Technology
Type
Heat PumpRefrigerant
R-410ACapacity Range
3 - 25 TonsEfficiency (SEER/IEER)
14.3, 15.0New unit control board with intuitive quick fan speed adjustment
New direct drive - EcoBlue™ Technology indoor fan system uses Vane Axial fan design & electronically commutated motor
Single-stage cooling capacity 04-06 models, two-stage on 07-28 models
SEERs to 14.3, IEER of 15.0
HSPF to 8.2 and COP’s to 3.6
Standard Cooling operating range up to 115 °F (46°C) and down to 40°F (4°C), lower temperature operation possible with low ambient kits
Innovative corrosive-resistant composite condensate pan in accordance with ASHRAE 62 Standard, sloping design; side or center drain
Proven high performance round copper tube and aluminum fin coil designs
Pre-painted exterior panels and primer-coated interior panels tested to 500 hours salt spray protection
04 to 06 models use fixed refrigerant metering device and 07-28 models use a TXV
New unit control board facilitating simple safety circuit troubleshooting and simplified control box arrangement as well as easy intuitive fan speed adjustment
Access panels with easy grip handles
Innovative, easy starting, no-strip screw feature on unit access panels
Tool-less filter access door
Optional hinged access panels also available
NEW Direct Drive – EcoBlue™ Technology Indoor fan system uses Vane Axial fan design and electronically commutated motor with beltless design
Two-inch disposable return air filters
Same footprint as prior Carrier models for that original fit; reduces installation costs and time
Field convertible from vertical to horizontal airflow configuration
Provisions for thru-the-bottom power entry capability as standard
Single point electrical and controls connections
Full perimeter base rail with built-in rigging adapters and fork truck slots
Scroll compressors with internal line-break overload protection
24-volt control circuit protected with resettable circuit breaker
Permanently lubricated direct-drive ECM evaporator-fan motor
Totally enclosed condenser motors with permanently lubricated bearings
Low pressure and high-pressure switch protection
Precisely sizes suction line accumulator
Proven Time/Temperature defrost logo and control board
5 years electric heaters
5 years parts only compressor
3 year SystemVu™ controller
One year parts only on all other parts
Additional extended warranty packages available
Temperature Sensing EconoMi$er with built-in relief
Enthalpy Sensing EconoMi$er with built-in relief
Multiple Electric Heat Sizes & Voltages
Return Air Smoke Detector
Supply Air Smoke Detector
CO2 Sensor
Condensate Overflow Protection
Multiple Static Fan Capabilities
Phase Monitor/Protection
Thru-The-Base Utility Connections
Louvered Hail Guards
Non-Fused Disconnect Switch
MERV-8 Return Air Filters
Hinged Access Panels
Unpowered Convenience Outlet
Powered Convenience Outlet
Coated Coils: Pre-Coat, E-Coat, Copper/Copper
Electrical Mechanical Controls
Intelligent SystemVu™ Integrated Communicating Controls
RTU-Open Communicating Controls
Extended Warranty Protection Plans
Financing Available
Nominal Cooling Ton Size | Cooling Stages | AHRI Efficiency (SEER) IEER | Dimensions (in) LxWxH | At 47°F | At 17°F | Approx. Unit Weight (lbs) | ||
| Heating Capacity (Btuh) | HSPF COP | Heating Capacity (Btuh) | HSPF COP | |||||
| 3 | 1 | (14.3) | 74 x 47 x 33 | 34000 | (8.2) | 17000 | n/a | 467 |
| 4 | 1 | (14.3) | 74 x 47 x 33 | 46600 | (8.2) | 23600 | n/a | 473 |
| 5 | 1 | (14.3) | 74 x 47 x 41 | 56500 | (8.2) | 30000 | n/a | 584 |
| 6 | 2 | 15.0 | 74 x 47 x 41 | 64500 | 3.60 | 35000 | 2.4 | 589 |
| 7.5 | 2 | 15.0 | 88 x 59 x 49 | 83000 | 3.40 | 48000 | 2.3 | 805 |
| 8.5 | 2 | 15.0 | 88 x 59 x 49 | 91000 | 3.40 | 55000 | 2.3 | 812 |
| 10 | 2 | 15.0 | 88 x 59 x 49 | 115000 | 3.40 | 66000 | 2.25 | 955 |
| 12.5 | 2 | 15.0 | 115 x 63 x 57 | 132000 | 3.30 | 82000 | 2.30 | 1250 |
| 15 | 2 | 14.0 | 127 x 86 x 49 | 168000 | 3.30 | 82000 | 2.30 | 1627 |
| 20 | 2 | 14.0 | 141 x 86 x 57 | 234000 | 3.30 | 82000 | 2.30 | 2057 |
| 25 | 2 | 14.0 | 141 x 86 x 57 | 274000 | 3.30 | 82000 | 2.30 | 2125 |
AHRI = Air-Conditioning, Heating & Refrigeration Institute
ASHRAE = American Society of Heating, Refrigerating and Air Conditioning, Inc.
IEER = Integrated Energy Efficiency Ratio
SEER = Seasonal Energy Efficiency Ratio
COP = Coefficient of Performance
HSPF = Heating Seasonal Performance Factor
NOTES
Accessory and Kit Data
Indoor Air Quality CO2 Sensor and Duct-Mounted Aspirator Box for use with EconoMi$er® IV System
Filter Kit Accessory for Small Rooftop Units Select 3 to 15 Ton Units, CRFLTTRK002A00-006A00
Ultra Low Leak Vertical EconoMi$er® X Accessory for Small Rooftop Units 3 to 12.5 Tons (48/50LC 14 Not Included) CRECOMZR067A01, CRECOMZR069A01, and CRECOMZR071A01
Ultra Low Leak Vertical EconoMi$er® 2 Accessory for Small Rooftop Units, 3 to 12.5 Tons, CRECOMZR066A01, CRECOMZR068A01, CRECOMZR070A01
Thru-the-Bottom Electric Connections, Thru-the-Curb Gas Connection Accessory for Gas Heating/Electric Cooling Small Rooftop Units, 3 to 6 Tons (50/60 Hz)
Thru-the-Bottom Electric and Gas Connections Accessory for Gas Heating/Electric Cooling Small Rooftop Units, 3 to 6 Tons (50/60 Hz)
Vertical EconoMi$er IV Accessory for Small Rooftop Products 3 to 12-1/2 Tons CRECOMZR020A02, CRECOMZR021A03, CRECOMZR062A00
CRDUCTCV001A00, CRDUCTCV002A00 Supply Air Duct Cover Accessory for Select 7.5, 10, 12.5 and 15 Ton Models
CRPWREXH068A00 CRPWREXH069A00 CRPWREXH070A00 Power Exhaust Accessory Single Package Rooftop Units 15 to 25 Tons
CRLVHLGD017-054A00 Louvered Hail Guard Accessory for Gas Heat/Electric Cooling, Electric Cooling and Heat Pump Select Rooftop Units 15-28 Tons
CRDISBKT001A00 Disconnect Switch Bracket Accessory for Commercial Packaged Heat Pump with Puron® (R-410A) Refrigerant, 10 Ton High Efficiency, 12.5 Ton Standard Efficiency, 7 1/2-10 Ton Ultra High Efficiency
CRECOMZR086A00 Horizontal Ultra Low Leak EconoMiSer X for Select 10 to 15 Tons
CRECOMZR088A00 Horizontal Ultra Low Leak EconoMiSer2 for Small Rooftop Products Select 10-15 Tons
CRECOMZR076A00, CRECOMZR078A00, CRECOMZR080A00 Vertical EconoMi$er® X Accessory for Small Rooftop Products Select 3 to 12-1/2 Tons
CRSTATUS001A00 Fan/Filter Status Switch Accessory for Small Rooftop Units Gas Heating/Electric Cooling, Electric Cooling and Heat Pump Units 3 to 15 tons
CRECOMZR087A00 Horizontal Ultra Low Leak EconoMiSer2 for Small Rooftop Products Select 10-15 Tons
Smoke Detector Accessory for Small Rooftop Units 3 to 15 Tons P/Ns CRSMKKIT003A00, CRSMKSEN003A00
Low Ambient Control Kit Accessory for Small Rooftop Units, 3 to 6 Tons, CRLAMBKT001A01
Louvered Hail Guard Accessory for Gas Heating/Electric Cooling, Electric Cooling and Heat Pump Rooftop Units, 3 to 15 Tons
CRECOMZR101A00-CRECOMZR108A00, Vertical/Horizontal Low Leak/Ultra Low Leak EconomizerONE Accessory for Small Rooftop Units Select 3 to 12.5 Tons
Competitor Roof Curb Adapter Accessory Kit, 3 to 12.5 Tons, CRLNXCURB12A00, CRLNXCURB34A00, CRTRACURB12A00, CRTRACURB34A00, CRYRKCURB12A00, CRYRKCURB34A00
CRECOMZR109A00, CRECOMZR110A00, CRECOMZR111A00, CRECOMZR112A00 Vertical/Horizontal Low Leak/Ultra Low Leak EconomizerONE Accessory for Small Rooftop Units Select 10 to 15 Tons
Horizontal EconoMi$er X Accessory for Small Rooftop Products Select 3 to 12-1/2 Tons (48/50LC 14 Not Included) CRECOMZR077A00, CRECOMZR079A00, CRECOMZR081A00
Low Ambient Control Kit Accessory for Small Rooftop Units Select 6 to 27.5 Tons
CRECOMZR113A00 and CRECOMZR114A00 Ultra Low Leak EconomizerONE Accessory for Medium Rooftop Units 15 to 27.5 Tons
Electric Heater and Single Point Box Accessory for Electric Cooling Small Rooftop Units, Select 3 to 6 Tons CRHEATER323A00-341A00, CRSINGLE037A00-041A00,060A00-063A00
Heater Accessory for Single Package Rooftop Units Select 17.5 to 27.5 Tons P/N CRHEATER454A00-CRHEATER471A00
Electric Heater and Single Point Box Accessory for Electric Cooling Select 6 to 15 Tons, P/N CRHEATER410A-428A, 451A-453A, CRSINGLE 042A00-045A00, 47A00, 049A00-053A00, 064A00-073A00
CRTRVUKT001A00 TruVu Controller Kit for Rooftop Units 48/50FE*04-16, 50FEQ04-14, 48/50GE*04-14, 50GEQ04-12, 48/50FC*04-16, 50FCQ04-14, 48/50GC*04-14 and 50GCQ04-12, 3 to 15 Tons
CRTRVUKT002A00 TruVu Controller Kit for Rooftop Units 48/50FE*20-30, 50FEQ17-28, 48/50GE*17-28, 50GEQ17-28, 48/50FC*20-30, 50FCQ17-28, 48/50GC*17-28, and 50GCQ17-28, 15 to 27.5 Tons
Brochure
Light Commercial RTUs - Smoke Detectors
Carrier Weather Series Packaged Heat Pumps with EcoBlue Technology
Light Commercial RTUs - 4 Inch Filter Rack - Web Version
Light Commercial RTUs - 4 Inch Filter Rack - Printer Version
Understanding the AIM Act
Staged Air Volume (SAV) System for Carrier’s Small and Medium Packaged Rooftop Units and Light Commercial Splits Systems
Controls
RTU Open Multi-Protocol Controller Factory-Installed Option for 48/50FC,GC,HC,KC,LC,TC and 50FCQ,GCQ,KCQ,HCQ,TCQ
50FCQ 04-28, 50GCQ 04-12 Single Package Rooftop Heat Pump Units with SystemVu™ Controls Version 4.X and Puron® (R-410A) Refrigerant
Guide Specifications
50FCQ Guide Specifications, 7.5 to 12.5 Nominal Tons (Honeywell)
50FCQ Guide Specifications, 15 to 25 Nominal Tons
50FCQ Guide Specifications, 7.5 to 12.5 Nominal Tons (Siemens)
50FCQ Guide Specifications, 3 to 6 Nominal Tons (Siemens)
Installation
50FCQ*08-12 WeatherMaker® Single Package Rooftop Heat Pump with Puron® (R-410A) Refrigerant and EcoBlue™ Fan Technology (Honeywell)
50FCQ*14 WeatherMaker® Single Package Rooftop Heat Pump with Puron® (R-410A) Refrigerant and EcoBlue™ Fan Technology (Honeywell)
50FCQ*04-07 WeatherMaker® Single Package Rooftop Heat Pump with Puron® (R-410A) Refrigerant (Honeywell)
50FCQ*17-28 WeatherMaker® Single Package Rooftop Heat Pump with Puron® (R-410A) Refrigerant and EcoBlue™ Fan Technology (Honeywell)
50FCQ*14 WeatherMaker® Single Package Rooftop Heat Pump with Puron® (R-410A) Refrigerant and EcoBlue™ Fan Technology (Siemens)
50FCQ*17-28 WeatherMaker® Single Package Rooftop Heat Pump with Puron® (R-410A) Refrigerant and EcoBlue™ Fan Technology (Siemens)
50FCQ*08-12 WeatherMaker® Single Package Rooftop Heat Pump with Puron® (R-410A) Refrigerant and EcoBlue™ Fan Technology (Siemens)
50FCQ*04-07 WeatherMaker® Single Package Rooftop Heat Pump with Puron® (R-410A) Refrigerant (Siemens)
Maintenance
50FCQ*04-07 Single Package Rooftop Heat Pump with Puron® (R-410A) Refrigerant (Honeywell)
50FCQ*08-14 Single Package Rooftop Heat Pump with Puron® (R-410A) Refrigerant (Honeywell)
50FCQ*17-28 WeatherMaker® Single Package Rooftop Heat Pump with Puron® (R-410A) Refrigerant and EcoBlue™ Fan Technology
50FCQ*04-07 Single Package Rooftop Heat Pump with Puron® (R-410A) Refrigerant (Siemens)
50FCQ*08-14 Single Package Rooftop Heat Pump with Puron® (R-410A) Refrigerant (Siemens)
Press Release
Press Release - Carrier Introduces Innovative EcoBlue Technology to Weather Series Packaged Heat Pumps
Product Data
50FCQ*08-14 WeatherMaker® Single Packaged Heat Pump Rooftop, 7.5 to 12.5 Nominal Tons (Honeywell)
50FCQ*17-28 WeatherMaker® Single Packaged Heat Pump Rooftop, 15 to 25 Nominal Tons
50FCQ*08-14 WeatherMaker® Single Packaged Heat Pump Rooftop, 7.5 to 12.5 Nominal Tons (Siemens)
50FCQ04-07 WeatherMaker® Single Packaged Heat Pump Rooftop, 3 to 6 Nominal Tons (Siemens)
REVIT and 3D DRW Files
50FCQ04-07 Family REVIT Files
Small Rooftop Revit Cheat Sheet - Tips and Tricks for Revit Family Files
50FCQ08,09 Family REVIT Files
50FCQ12 Family REVIT Files
50FCQ14 Family REVIT Files
50FCQ20,25 Family REVIT Files
50FCQ17 Family REVIT Files
Warranty Card
Limited Warranty for Light Commercial Equipment