Special Seismic Compliance Brochure
AquaEdge® 19DV Water-Cooled Centrifugal Chiller
Compressor Type
CentrifugalRefrigerant
R-1233 zd(E)Capacity Range
350 - 1,150 TonsCapacity Range
1,231 - 4,044 kWAvailable Software
PLV ProLow energy consumption during part load and full load operation
IPLV down to 0.295
R-1233 zd(E) refrigerant with A1 safety rating
EquiDrive™ back to back two-stage compressor with Independent Guide Vane Control
Refrigerant lubricated ceramic bearings
Hybrid falling film evaporator
Crescent shaped economizer
Touchscreen control panel with multilingual display
Compatible with Carrier Comfort Network® (CCN) communication link
ASME constructed heat exchangers
Two-stage 350-1,150 tons (1231 to 4044 kW) compressor with no scheduled teardown
Semi-hermetically sealed compressor and motor
Automated controls may be tested before start-up
Air-cooled, non-ventilated, totally enclosed variable frequency drive
Password protected extensive service menu with built-in diagnostic capabilities, troubleshooting, and corrective action recommendations for preset alarms
Alarm and alert files maintain the last 25 time and date stamped messages in memory
Configuration data backup with non-volatile memory
Thermistor-type temperature sensor with quick connects in each water nozzle
Steel single rupture disk
Service contract available
Low voltage control circuits
Automated controls test on start-up
One year from start-up or 18 months from shipment
Refrigerant warranty 5 years from date of manufacture (US & Canada Only)
Extended warranties available (US & Canada Only)
Enhanced tubing, .028 or .035 in. (0.711 or 0.889 mm): Internally/externally enhanced copper tubing – evaporator/condenser
Marine waterboxes: 150 psig (1034 kPa) waterbox
Flanged evaporator and/or condenser waterbox nozzles
1, 2, or 3 pass evaporator or condenser waterside construction
Economizer bypass valve
Modulating Envelope stability control (hot gas bypass)
Free cooling
IEEE-519 Option
BACnet® communications
Customer factory performance testing
Export crating
Extended Warranty (North America only)
Service Contract
BACnet® Carrier translator
LonWorks® Carrier translator
Sensor package
Separate storage tank and pumpout unit
Stand-alone pumpout unit
Soleplate package
Spring isolator kit
| Condenser Heat Exchanger Size | A (length, dished head waterbox) | 19DV B Width (ft-in/mm) | 19DV C Height (ft-in/mm) | ||
| 1-Pass (ft-in/mm) | 2-Pass* (ft-in/mm) | 3-Pass* (ft-in/mm) | |||
| F2* | 15'6"/4724 | 14’ 10.5”/4535 | 15’ 6”/4714 | 8’ 4.04”/2549 | 9’ 3”/2822 |
| F4* | 17’ 2”/5245 | 16’ 5.5”/5055 | 17’ 1”/5235 | 8’ 4.04”/2549 | 9’ 3”/2822 |
| G2* | 15' 7.5"/4763 | 15' 0.375"/4582 | 15' 4"/4674 | 8' 3.625"2530 | 9' 6.25"/2902 |
| G4* | 17' 4"/5283 | 16' 8.875"/5102 | 17' 0.5"/5194 | 8' 3.625"/2530 | 9' 6.25"/2902 |
| H2* | 15’ 10.8”/4847 | 15’ 3.285”/4655 | 15’ 7.4”/4761 | 9’ 4.272”/2852 | 10’ 3.9”/3147 |
| H4* | 17’ 7.3”/5367 | 16’ 11.785”/5176 | 17’ 3.9”/5281 | 9’ 2.215”/2799 | 10’ 3.9”/3147 |
*Assumed 2-pass nozzles on same end.
| Heat Exchanger Size | Passes | A (length, with nozzle-in-head waterbox) (in/mm) | B Width (in/mm) | C Height (in/mm) |
| M4* | 1 | - | 131.6/3343 | 142.8/3745 |
| M4* | 2 | 206.1/5234 | 131.6/3343 | 142.8/3745 |
| M4* | 3 | - | 131.6/3343 | 142.8/3745 |
| M6* | 1 | - | 131.6/3343 | 142.8/3745 |
| M6* | 2 | 225.9/5736 | 131.6/3343 | 142.8/3745 |
| M6* | 3 | - | 131.6/3343 | 142.8/3745 |
*Assumed 2-pass nozzles on same end.
Brochure
Special Seismic Compliance Brochure
Heat Reclaim Chillers - Web Version
Aqua Series Water-Cooled Chillers Brochure
AquaEdge® 19DV Water-Cooled Centrifugal Chiller with Awards Brochure
A World of Comfort 2025 - Brochure
Capacity Recovery - Reliable Uptime for Mission Critical Facilities Brochure
Cost-Effective Energy Solutions for Your Chilled Water Plant
Carrier AHRI Approved Laboratory
Carrier QuantumLeap Data Centers Solutions
Vibration Analysis: Evaluate Your Chiller Performance
A World of Comfort 2025 - Brochure (Printer Version)
Case Study
Wake Tech East Central Energy Plant
Controls
19DV AquaEdge® Two-Stage High-Efficiency Semi-Hermetic Centrifugal Liquid Chillers with PIC6 Controls
Guide Specifications
19DV Guide Specifications, 350 to 800 Nominal Tons (1231 to 4044 Nominal kW)
Installation
19DV AquaEdge® High-Efficiency Semi-Hermetic Centrifugal Liquid Chillers with Greenspeed® Intelligence,PIC6 Controls, and HFO R-1233zd(E), 350 to 1,150 Nominal Tons (1,231 to 4,044 kW) 50/60 Hz
Maintenance
19DV AquaEdge® Two-Stage Back-to-Back Centrifugal Liquid Chillers with PIC6 Controls and HFO R-1233zd(E) 50/60 Hz
Presentation
Carrier Chiller Heat Recovery Video
Carrier 19DV Chiller Heat Recovery Video
Press Release
Press Release - Carrier Previews AquaEdge® 19DV Centrifugal Chiller with Environmentally Sustainable Refrigerant
Press Release - AquaEdge® 19DV Centrifugal Chiller is Now Available in North America
Press Release - Carrier Innovations Named Finalists in Consulting-Specifying Engineer® Magazine’s Product of the Year Competition
Press Release - Carrier Releases Updated Chiller Mobile App
Press Release - Carrier® AquaEdge® 19DV Chiller Wins Fifth Major Award in Past Year
Press Release - Carrier® AquaEdge® 19DV Chiller Line Expanded to 350 Tons
Press Release: Carrier AquaEdge 19DV Chiller Line Expands to 1150 Tons
Press Release - Carrier Adds Seismic Certification for Award-Winning AquaEdge 19DV Water-Cooled Chiller
Product Data
19DV AquaEdge® High-Efficiency Semi-Hermetic Centrifugal Liquid Chillers with Greenspeed® Intelligence, PIC6 Controls, and HFO-1233zd(E) Refrigerant, 350 to 1150 Nominal Tons (1231 to 4044 Nominal kW)
REVIT and 3D DRW Files
19DV-F Revit Family File
19DV-G Revit Family File
19DV-H Revit Family File
19DV-M Revit Family File
Warranty Card
Limited Warranty for Commercial Equipment
Refrigerant Warranty Certificate for Water Cooled Chillers, US and Canada Only
White Paper
Variable Frequency Drive, Operation and Application of Variable Frequency Drive (VFD) Technology
Chilled Water System Optimizer