i-Vu® Pro 10.0

Technical Specifications

New Features

Insights Sharing: Deliver building automation insights, such as dashboards, trends, and reports-to stakeholders without BAS access, on-demand or on a set schedule. For users with BAS access, share a secure link to a specific page in the BAS. 

Enhanced Trend Capabilities: Analyze data faster and easier with more data per graph and customizable colors. 

Live System Backups for Rapid Recovery: Help safeguard your i-Vu system without interruption. Schedule full or partial backups (on-premises only) anytime, and store them wherever you choose, including our secure cloud. It’s a smart way to ensure fast, reliable recovery when you need it most. 

Smarter BACnet Discovery: Define where and how to scan BACnet networks, making discovery faster, more efficient, and easier to manage. 

Robust Security & Compliance: Strengthen system defenses with the latest security patches to help ensure protection against known vulnerabilities. The BAS system also adheres to industry standards and uses modernized components for a more secure and compliant system.

Enhanced Engineering Tools: Boost efficiency and accuracy for technicians, integration specialists, and end users by streamlining workflows. 

Fast, Accurate, Commissioning (ACxelerate 3.0 add-on): With a refreshed interface and enhanced reporting, ACxelerate 3.0 simplifies auto-commissioning of dampers and reheat valves in single-duct, dual-duct, and fan-powered VAV units, helping teams save time, minimize errors, and stay compliant. 

Predictive Insights (Add-On): Powered by AI, this tool transforms i-Vu into a proactive diagnostic and optimization engine that continuously monitors HVAC and BAS data. This convenient subscription service enables AI-powered predictive maintenance, helping facility teams anticipate issues, reduce downtime, and optimize energy performance.

Standard Features

Intuitive & Comprehensive User Interface: i-Vu is a comprehensive building management solution with a single, uniform interface, accessible from any internet-connected device. It integrates all building systems and uses dynamic floor plans for a quick, visual overview, making it easy to use and reducing training time. 

Open & Interoperable: With its open BACnet standards, the i-Vu platform seamlessly integrates with various third-party systems and uses pre-engineered control programs to simplify system setup and provide centralized control of building systems.

Operational & Energy Efficiency: Pre-engineered control programs, scheduling, and integrated energy-saving strategies help to ensure cost-effective operation. Energy reporting and analytics tools help reduce maintenance costs through proactive fault detection and diagnostics.

Equipment & Controls Synergy: i-Vu seamlessly integrates with Carrier HVAC equipment to create a complete, optimized solution that streamlines operations and improves energy efficiency, performance, and occupant comfort. 

Enhanced Cybersecurity: The i-Vu system includes robust security features like encryption, access controls, and intrusion detection to help protect your building from cyberattacks and secure your data. 

Flexible & Scalable: The i-Vu platform is a versatile and scalable solution engineered to meet your unique requirements. It can accommodate buildings of all sizes and support unlimited simultaneous users, enabling you to build a control network your facility demands. 

Backward Compatibility: i-Vu is committed to backward compatibility, with seamless integration with legacy CCN, Open controllers, and modern Carrier TruVu™ controls. This is essential for maintaining operational continuity and reducing costs.

Software Editions & Part Numbers

NamePart #DevicesFeatures
i-Vu 10.0 Pro-5CIV-OPNPR5Up to 5i-Vu Pro 5; PC based web server application supports up to 5 controllers.
i-Vu 10.0 Pro-32CIV-OPNPR32Up to 32i-Vu Pro 32; PC based web server application supports up to 32 controllers.
i-Vu 10.0 Pro-750CIV-OPNPRUp to 750i-Vu Pro; PC based web server application supports up to a total of 750 controllers.
i-Vu 10.0 Pro UnlimitedCIV-OPNPRULUnlimitedi-Vu Pro Unlimited; PC based web server application supports unlimited controllers.
i-Vu CloudCIV-OPNPRCUnlimited (SaaS)i-Vu Cloud New Customer License
i-Vu Cloud UpgradeCIV-OPNPRCUGUnlimited (SaaS)i-Vu On-Prem to Cloud Upgrade
i-Vu 10.0 Life SciencesCIV-OPNPRLSUnlimitedi-Vu Pro Life Sciences; Includes: ADD-LDAP/SSO, ADD-TRNDEXP, and i-Vu Pro Unlimited with added compliance with FDA 21CFR Part 11. Which includes Preconfigured, Life Science Compliance Reports, and Digital signing of reports. Includes software license only.

Specifications

Mobile DevicesSmart phones Android™, iOS | Tablets: Android, iOS, Surface™
Supported Browsers per Operating System WindowsMac OS (Apple Mac only)Linux
Google™ Chrome™ v84.0 or later
Microsoft® Edge v84 or later--
Mozilla® Firefox® v79.0 or later
Safari® v11 or later--
Server Requirements (Server sold separately)
SpecsQuad core processor, 4GB RAM, 100Mbps or higher LAN communications
OSThe following operating systems in 64-bit versions: Windows® 11 Professional and Enterprise Windows Server 2025 | Windows Server 2022 | Windows Server 2019 | Windows Server 2016
Other Features
DatabaseApache Derby is the default database engine-included with purchase for the i-Vu Pro v10.0 system The i-Vu Pro v10.0 system also supports the following and database engines are sold separately: SQL Server® Express 2019, 2017, 2016 | SQL Server 2022, 2019, 2017, 2016 | Oracle 19c | MySQL through 8.0 LTS | PostgreSQL 12 through 17.2
SecuritySupports TLS (Transport Layer Security) v1.3 with 256 bit encryption between client and i-Vu server Bacnet Secure Connect (BACnet/SC) secure, encrypted datalink layer
SupportsUnlimited simultaneous users Communication to field controllers via BACnet (TCP/IP)
LanguagesInternational English, Brazilian Portuguese, Dutch, Finnish, French, French Canadian, German, Italian, Japanese, Korean, Norwegian, Russian, Simplified Chinese, Spanish, Swedish, Thai, Traditional Chinese, Vietnamese
BACnetAdvanced Operator Workstation (B-AWS) supporting BACnet Revision 19

Documents

Application Guide

i-Vu Pro - ER Data Connector v1.3 User Guide

i-Vu® Application Upgrade Guide to v8.5

Security Best Practices for an i-Vu Pro v8.5 system

Using REST APIs in i-Vu v9.0

Security Best Practices for an i-Vu Pro v9.0 system

i-Vu® Application Upgrade Guide to v9.0

i-Vu Pro v8.5 and later - ER Data Connector User Guide

i-Vu Application Upgrade Guide to v10.0

Security Best Practices for an i-Vu Pro v10.0 system

Using REST APIs in i-Vu v10.0

Brochure

VVT Zoning System Brochure Low Resolution 1/21

VVT Zoning System Brochure High Resolution 1/21

VVT Zoning System Brochure Print Version 1/21

i-Vu Building Automation System Brochure - Low Resolution 1/21

Carrier Controls - Complete System Solutions Brochure

i-Vu - DISCOVER A SMARTER PLATFORM FOR MANAGING YOUR BUILDINGS Low Res 9/22

i-Vu DISCOVER A SMARTER PLATFORM FOR MANAGING YOUR BUILDINGS High Res 9/22

i-Vu - DISCOVER A SMARTER PLATFORM FOR MANAGING YOUR BUILDINGS Printer Version 9/22

i-Vu - DISCOVER A SMARTER PLATFORM FOR MANAGING YOUR BUILDINGS Spreads

Case Study

UW Credit Union

Christian Health Care

Listrak Corporate Headquarters

University Hospitals Ashtabula Health Center

evolv1 building

Configuration

i-Vu Pro: Automated Demand Response Add-on v1.3 Overview and Configuration

i-Vu Plus/Pro v6.5 or later: Tenant Override Billing V3.1.2 Installation Guide

ACxelerate Automated Commissioning Tool - Overview and Configuration

Controls

i-Vu Open Operator Interface Guide Specification

Installation

Installing an Add-on for I-Vu® v6.5

i-Vu 6.5 Pro: BACnet Scheduling Add-on User Guide

i-Vu 6.5 Pro: MS Exchange Scheduling Add-on User Guide V 1.2

i-Vu Pro v6.5: LDAP/AD v1.2 Add-on User Guide

i-Vu 7.0 Pro: BACnet Scheduling v1.1 Add-on User Guide

i-Vu 8.5 and later Pro: MS Exchange Scheduling Add-on User Guide

i-Vu® Pro v7.0 Installation Guide

i-Vu® Pro v7.0 Operating System Requirements

i-Vu® v7.0 Microblock Reference

i-Vu® v7.0 Pro SiteBuilder Help

i-Vu Pro v8.5 or later: ProxyConfig v8.5 Add-on User Guide

i-Vu® 7.0 Plus/Pro: Improved Edit Order User Guide

EMS Scheduling Add-on User Guide

i-Vu Pro: EcoReports Data Connector User Guide V1.2

i-Vu Pro: 17-01 Door Status Integration Add-on v1.0 User Guide

i-Vu Pro v7.0 or later: LDAP/AD v1.3 Add-on User Guide

i-Vu® Pro v8.0 Operating System Requirements

i-Vu® Pro v8.0 Installation Guide

i-Vu® v8.0 Microblock Reference

i-Vu® v8.0 Pro SiteBuilder Help

i-Vu Pro BACnet Scheduling Add-on User Guide

i-Vu® 8.0 or later : Improved Edit Order v1.2 User Guide

BACnet/SC Setup Guide

BACNet/SC Virtual Hub Installation and Startup Guide

i-Vu v8.5 or later: Autopilot Setup Guide

i-Vu® Pro v8.5 Installation Guide

i-Vu® Pro v8.5 Operating System Requirements

i-Vu® Pro v8.5 What's New

i-Vu® v8.5 Microblock Reference

i-Vu v8.5 SiteBuilder Help

i-Vu® Pro v8.0 What's New

Weather Add-On Version 3.0 User Guide for i-Vu v8.0 or later

i-Vu® v9.0 Microblock Reference

i-Vu® Pro v9.0 Operating System Requirements

i-Vu® Pro v9.0 Installation Guide

i-Vu® Pro v9.0 What's New

AddressIT User Guide

i-Vu Pro v10.0 Installation Guide

i-Vu Pro v10.0 What's New

i-Vu® v10.0 Microblock Reference

SiteBuilder User Guide v10.0

i-Vu® Pro v10.0 Operating System Requirements

Weather Add-on User Guide for i-Vu v8.5 or later

Operation

i-Vu ViewBuilder v7.0 Application Guide

ViewBuilder v8.0 Help

Press Release

Press Release - New - Version 7.0 i-Vu® Building Automation System

Product Data

i-Vu System Sell Sheet

i-Vu Alarming Product Data Sheet

i-Vu Tenant Billing Product Data Sheet

i-Vu Scheduling Product Data Sheet

i-Vu Trending and Reports Product Data Sheet

Trend Export Add-On V2.6.3 for i-Vu Pro Product Data Sheet

Weather Add-On v3.0 Product Data Sheet

i-Vu Pro: MS Exchange Scheduling Add-on Product Data

i-Vu Pro EcoReports Dashboards Edition Product Data

i-Vu Pro: 17-01 Door Status Add-on Product Data

Abound Predictive Insights Product Data

i-Vu Pro 9.0 User Interface Product Data Sheet

Carrier Specifier's Guide to Smart BAS

i-Vu Pro 10.0 User Interface Product Data Sheet

i-Vu Version Comparison

i-Vu v10 Frequently Asked Questions

White Paper

Intelligent Air Source and Terminal Integration

Environmental Design Considerations for Hospital Operating Rooms White Paper

Need assistance? Ask Carrier.

Get in touch