Gemini™
40RUA
Packaged Air Handler
DX cooling only
with Puron® (R-410A) refrigerant
21 to 105 Nominal kW
6 to 30 Nominal Tons
3,058 to 25,485 m³/h
1,800 to 15,000 cfm
The Gemini™ 40RU and 38AU series indoor air handlers and outdoor units provide a wide variety of options for your HVAC application needs. These units are designed for long dependable operation whether it’s a rooftop or on-the-ground installation. All Gemini 38AU Condensing Units and 40RU Fan Coils use environmentally sound Puron® refrigerant. Together, they create a reliable split system that provides easy solutions to a wide range of commercial HVAC needs.
The 40RU series have a multi-position design that allows for vertical or horizontal installation with no modifications. Powerful fan systems allow easy adaptation to existing ductwork. For heating capability, the 40RU’s allow for field installed electric heaters, hot water coils, or steam coils.
Performance Features
- Uses field-supplied Puron® (R-410A) refrigerant.
- Non-corroding drain pans.
- Cleanable insulation treated with an anti-microbial agent.
- Fan motor options allowing more complex new or replacement air distribution systems.
- Powerful belt-driven forward curved centrifugal fans.
- Durable die-formed galvanized steel casings.
- Direct expansion cooling coils are rated in accordance with ARI standard 340/360 when paired with Carrier 38A cooling only condensing units.
Reliability Features
- Precision thermostatic expansion valve (TXV) with removable power element on each circuit.
- Motor overload protection of internal automatic reset thermal overload protection.
- Designed and constructed in accordance with UL 1995 standard.
- Listed with ETL and ETL, Canada.
Installation Features
- Vertical or horizontal installation without modification.
- Simple voltage conversion on tri-voltage 208/230/460-3-60 motors.
- Front or bottom return air intake.
- Two sloped condensate pans for horizontal or vertical applications.
- Simple condensate drain pan adjustment for right-hand or left-hand operation.
- Easy-access 24-volt control terminal block for easy thermostat wiring.
- Single point electrical power connection for fan motor and accessory electrical heaters.
Maintenance Features
- Removable side panel allows access to virtually all components.
- Permanently lubricated, sealed motor bearings.
- Easy filter replacement with slide-out retainer.
Standard Limited Warranty
- One year parts only.
Factory-Installed Options
- Unit voltage options:
- 208/230-3-60
- 460-3-60
- 575-3-60
- 208/230-1-60 (sizes 07 and 08)
- 400-3-50
- Staged Air Volume (SAV) indoor fan speed system (sizes 12-30).
- Alternate fan motors.
- Medium and high-static drives.
- Pre-painted units.
Field-Installed Accessories
- Outside air enthalpy controlled economizer.
- Fully sheathed electric heater.
- Hot water heating coils.
- Steam heating coil.
- Programmable thermostats.
- CO2 sensors.
- Airflow sensor switch.
- Painted and non-painted options:
- Discharge plenum
- Return air grille
- Floor mount subbase
- Condensate overflow switch assembly.
- Overhead suspension package.
40RUA Matched with 38AUZ Single Circuit Air-Cooled Condensing Unit
| Unit | Cooling stages | Nominal capacity (Tons) | Net cooling capacity (MBH) | Total power (kW) | EER | IEER |
|---|---|---|---|---|---|---|
| 38AUZ07/40RUA07 | 1 | 6 | 71 | 6.2 | 11.5 | 12.2 |
| 38AUZ08/40RUA08 | 1 | 7.5 | 92 | 8.2 | 11.2 | 11.8 |
| 38AUZ12/40RUA12 | 1 | 10 | 117 | 10.4 | 11.2 | 12.0 |
| 38AUZ14/40RUA14 | 1 | 12.5 | 148 | 13.5 | 11.0 | 12.0 |
| 38AUZ16/40RUA16 | 1 | 15 | 184 | 16.4 | 11.2 | 13.2 |
| 38AUZ25/40RUA25 | 1 | 20 | 240 | 21.8 | 11.0 | 11.2 |
40RUA Matched with 38AUD Dual Circuit Air-Cooled Condensing Unit
| Unit | Cooling stages | Nominal capacity (Tons) | Net cooling capacity (MBH) | Total power (kW) | EER | IEER |
|---|---|---|---|---|---|---|
| 38AUD12/40RUA12 | 2 | 10 | 117.0 | 10.4 | 11.2 | 11.6 |
| 38AUD14/40RUA14 | 2 | 12.5 | 148.0 | 13.4 | 11.0 | 11.8 |
| 38AUD16/40RUA16 | 2 | 15 | 184.0 | 16.4 | 11.2 | 11.8 |
| 38AUD25/40RUA25 | 2 | 20 | 240.0 | 21.6 | 11.0 | 11.2 |
LEGEND
AHRI = Air-Conditioning, Heating and Refrigeration Institute
ASHRAE = American Society of Heating, Refrigerating and Air Conditioning, Inc.
EER = Energy Efficiency Ratio
IEER = Integrated Energy Efficiency Ratio
COP = Coefficient of Performance
NOTES:
1. Rated in accordance with ARI Standard 340/360---07, as appropriate.
2. Ratings are based on:
- Cooling Standard: 27°C (80°F) db, 19°C (67°F) wb indoor air temp and 35°C (95°F) db outdoor air temp.
- IEER Standard: 27°C (80°F) db, 19°C (67°F) wb indoor air temp and 4 various outdoor temperatures.
3. All units comply with ASHRAE 90.1 Energy Standard for minimum EER and IEER requirements.
Physical Data
| Size | Nominal capacity (tons) | Base unit operating weight (lbs) | Nominal airflow (cfm) | Airflow range (cfm) |
|---|---|---|---|---|
| 07 | 6 | 399 | 2,400 | 1,800-3,000 |
| 08 | 7.5 | 404 | 3,000 | 2,250-3,750 |
| 12 | 10 | 425 | 4,000 | 3,000-5,000 |
| 14 | 12.5 | 695 | 5,000 | 3,750-6,250 |
| 16 | 15 | 713 | 6,000 | 4,500-7,500 |
| 25 | 20 | 730 | 8,000 | 6,000-10,000 |
| 28 | 25 | 1050 | 10,000 | 7,500-12,500 |
| 30 | 30 | 1062 | 12,000 | 9,000-15,000 |
-
33WIFISTAT43 Wi-Fi Thermostat Published Date: 8/15/2024
-
Economizer Accessory for Packaged Air-Handling Units, 6 to 30 tons, 50/60 Hz Published Date: 8/5/2021
-
Hot Water and Steam Coil Accessories for Packaged Air-Handling Units, 6 to 30 Tons Published Date: 5/3/2019
-
Overhead Suspension Accessory for Packaged Air-Handling Units, 6 to 30 tons Published Date: 7/16/2015
-
Packaged Air-Handling Units 6 to 30 tons Condensate Drain Trap Accessory 50/60 Hz Published Date: 7/16/2015
-
Packaged Air-Handling Units Subbase Accessory, 6 to 30 tons Published Date: 7/16/2015
-
Plenum and Return-Air Grille Accessories for Packaged Air-Handling Units, 6 to 30 tons Published Date: 7/16/2015
-
Ultraviolet Lamp Accessory for Package Air-Handling Units 6 to 30 Tons Published Date: 1/7/2022
-
Variable Frequency Drive (VFD) Remote Keypad Kit CRDISKIT001A00 and CRDISKIT003A00 Published Date: 10/9/2025
-
A World of Comfort 2025 - Brochure Published Date: 6/11/2025
-
A World of Comfort 2025 - Brochure (Printer Version) Published Date: 6/11/2025
-
New Carrier® Staged Air Volume SAV™ System Brochure Published Date: 1/24/2015
-
Understanding the AIM Act Published Date: 3/10/2022
-
40RUA Guide Specifications, 44 to 106 kW (12.5 to 30 Nominal Tons) 50 Hz Published Date: 12/2/2024
-
40RUA/40RUS Guide Specifications, 5,000 to 12,000 Nominal Cfm, 12.5 To 30 Nominal Tons Cooling Published Date: 10/9/2025
-
40RU 14-16 Packaged Air-Handling Units with Puron (R-410A) Refrigerant, 50 Hz Published Date: 12/2/2024
-
40RU 14-16 Packaged Air-Handling Units with Puron (R-410A) Refrigerant, 60 Hz Published Date: 4/23/2025
-
40RU 25-30 Packaged Air-Handling Units, 60 Hz, with Puron (R-410A) Refrigerant Published Date: 4/23/2025
-
40RU 25-30 Packaged Air-Handling Units, with Puron (R-410A) Refrigerant, 50 Hz Published Date: 12/2/2024
-
40RFA 07-12, 40RFS 08-12, 40RUA/40RUS 14-30 Packaged Air-Handling Units, 6 to 30 Nominal Tons Published Date: 10/9/2025
-
40RFA 07-12, 40RUA 14-30 Packaged Air-Handling Units with Puron (R-410A) Refrigerant, 21-106 kW, 50 Hz Published Date: 12/2/2024
-
40RUA, 40RUQ, 40RUS 12-30 Ton Packaged Air Handling Horizontal Units with No Heat Family REVIT Files Published Date: 4/23/2019
-
40RUA, 40RUQ, 40RUS 12-30 Ton Packaged Air Handling Vertical Units with Electric Heat Family REVIT Files Published Date: 4/23/2019
-
40RUA, 40RUQ, 40RUS 12-30 Ton Packaged Air Handling Vertical Units with No Heat Family REVIT Files Published Date: 4/23/2019
-
40RUA, 40RUQ, 40RUS 6-10 Ton Packaged Air Handling Horizontal Units with No Heat Family REVIT Files Published Date: 4/23/2019
-
40RUA, 40RUQ, 40RUS 6-10 Ton Packaged Air Handling Vertical Units with Electric Heat Family REVIT Files Published Date: 4/23/2019
-
40RUA, 40RUQ, 40RUS 6-10 Ton Packaged Air Handling Vertical Units with No Heat Family REVIT Files Published Date: 4/23/2019
-
40RUA, 40RUQ, 40RUS 6-30 Ton Packaged Air Handling Horizontal Units with Steam Heat Family REVIT Files Published Date: 4/23/2019
-
40RUA, 40RUQ, 40RUS 6-30 Ton Packaged Air Handling Units with Plenum Family REVIT Files Published Date: 4/23/2019
-
40RUA, 40RUQ, 40RUS 6-30 Ton Packaged Air Handling Vertical Units with Hot Water Heat Family REVIT Files Published Date: 4/23/2019
-
40RUA, 40RUQ, 40RUS 6-30 Ton Packaged Air Handling Vertical Units with Steam Heat Family REVIT Files Published Date: 4/23/2019
Performance Features
- Uses field-supplied Puron® (R-410A) refrigerant.
- Non-corroding drain pans.
- Cleanable insulation treated with an anti-microbial agent.
- Fan motor options allowing more complex new or replacement air distribution systems.
- Powerful belt-driven forward curved centrifugal fans.
- Durable die-formed galvanized steel casings.
- Direct expansion cooling coils are rated in accordance with ARI standard 340/360 when paired with Carrier 38A cooling only condensing units.
Reliability Features
- Precision thermostatic expansion valve (TXV) with removable power element on each circuit.
- Motor overload protection of internal automatic reset thermal overload protection.
- Designed and constructed in accordance with UL 1995 standard.
- Listed with ETL and ETL, Canada.
Installation Features
- Vertical or horizontal installation without modification.
- Simple voltage conversion on tri-voltage 208/230/460-3-60 motors.
- Front or bottom return air intake.
- Two sloped condensate pans for horizontal or vertical applications.
- Simple condensate drain pan adjustment for right-hand or left-hand operation.
- Easy-access 24-volt control terminal block for easy thermostat wiring.
- Single point electrical power connection for fan motor and accessory electrical heaters.
Maintenance Features
- Removable side panel allows access to virtually all components.
- Permanently lubricated, sealed motor bearings.
- Easy filter replacement with slide-out retainer.
Standard Limited Warranty
- One year parts only.
Factory-Installed Options
- Unit voltage options:
- 208/230-3-60
- 460-3-60
- 575-3-60
- 208/230-1-60 (sizes 07 and 08)
- 400-3-50
- Staged Air Volume (SAV) indoor fan speed system (sizes 12-30).
- Alternate fan motors.
- Medium and high-static drives.
- Pre-painted units.
Field-Installed Accessories
- Outside air enthalpy controlled economizer.
- Fully sheathed electric heater.
- Hot water heating coils.
- Steam heating coil.
- Programmable thermostats.
- CO2 sensors.
- Airflow sensor switch.
- Painted and non-painted options:
- Discharge plenum
- Return air grille
- Floor mount subbase
- Condensate overflow switch assembly.
- Overhead suspension package.
40RUA Matched with 38AUZ Single Circuit Air-Cooled Condensing Unit
| Unit | Cooling stages | Nominal capacity (Tons) | Net cooling capacity (MBH) | Total power (kW) | EER | IEER |
|---|---|---|---|---|---|---|
| 38AUZ07/40RUA07 | 1 | 6 | 71 | 6.2 | 11.5 | 12.2 |
| 38AUZ08/40RUA08 | 1 | 7.5 | 92 | 8.2 | 11.2 | 11.8 |
| 38AUZ12/40RUA12 | 1 | 10 | 117 | 10.4 | 11.2 | 12.0 |
| 38AUZ14/40RUA14 | 1 | 12.5 | 148 | 13.5 | 11.0 | 12.0 |
| 38AUZ16/40RUA16 | 1 | 15 | 184 | 16.4 | 11.2 | 13.2 |
| 38AUZ25/40RUA25 | 1 | 20 | 240 | 21.8 | 11.0 | 11.2 |
40RUA Matched with 38AUD Dual Circuit Air-Cooled Condensing Unit
| Unit | Cooling stages | Nominal capacity (Tons) | Net cooling capacity (MBH) | Total power (kW) | EER | IEER |
|---|---|---|---|---|---|---|
| 38AUD12/40RUA12 | 2 | 10 | 117.0 | 10.4 | 11.2 | 11.6 |
| 38AUD14/40RUA14 | 2 | 12.5 | 148.0 | 13.4 | 11.0 | 11.8 |
| 38AUD16/40RUA16 | 2 | 15 | 184.0 | 16.4 | 11.2 | 11.8 |
| 38AUD25/40RUA25 | 2 | 20 | 240.0 | 21.6 | 11.0 | 11.2 |
LEGEND
AHRI = Air-Conditioning, Heating and Refrigeration Institute
ASHRAE = American Society of Heating, Refrigerating and Air Conditioning, Inc.
EER = Energy Efficiency Ratio
IEER = Integrated Energy Efficiency Ratio
COP = Coefficient of Performance
NOTES:
1. Rated in accordance with ARI Standard 340/360---07, as appropriate.
2. Ratings are based on:
- Cooling Standard: 27°C (80°F) db, 19°C (67°F) wb indoor air temp and 35°C (95°F) db outdoor air temp.
- IEER Standard: 27°C (80°F) db, 19°C (67°F) wb indoor air temp and 4 various outdoor temperatures.
3. All units comply with ASHRAE 90.1 Energy Standard for minimum EER and IEER requirements.
Physical Data
| Size | Nominal capacity (tons) | Base unit operating weight (lbs) | Nominal airflow (cfm) | Airflow range (cfm) |
|---|---|---|---|---|
| 07 | 6 | 399 | 2,400 | 1,800-3,000 |
| 08 | 7.5 | 404 | 3,000 | 2,250-3,750 |
| 12 | 10 | 425 | 4,000 | 3,000-5,000 |
| 14 | 12.5 | 695 | 5,000 | 3,750-6,250 |
| 16 | 15 | 713 | 6,000 | 4,500-7,500 |
| 25 | 20 | 730 | 8,000 | 6,000-10,000 |
| 28 | 25 | 1050 | 10,000 | 7,500-12,500 |
| 30 | 30 | 1062 | 12,000 | 9,000-15,000 |
-
33WIFISTAT43 Wi-Fi Thermostat Published Date: 8/15/2024
-
Economizer Accessory for Packaged Air-Handling Units, 6 to 30 tons, 50/60 Hz Published Date: 8/5/2021
-
Hot Water and Steam Coil Accessories for Packaged Air-Handling Units, 6 to 30 Tons Published Date: 5/3/2019
-
Overhead Suspension Accessory for Packaged Air-Handling Units, 6 to 30 tons Published Date: 7/16/2015
-
Packaged Air-Handling Units 6 to 30 tons Condensate Drain Trap Accessory 50/60 Hz Published Date: 7/16/2015
-
Packaged Air-Handling Units Subbase Accessory, 6 to 30 tons Published Date: 7/16/2015
-
Plenum and Return-Air Grille Accessories for Packaged Air-Handling Units, 6 to 30 tons Published Date: 7/16/2015
-
Ultraviolet Lamp Accessory for Package Air-Handling Units 6 to 30 Tons Published Date: 1/7/2022
-
Variable Frequency Drive (VFD) Remote Keypad Kit CRDISKIT001A00 and CRDISKIT003A00 Published Date: 10/9/2025
-
A World of Comfort 2025 - Brochure Published Date: 6/11/2025
-
A World of Comfort 2025 - Brochure (Printer Version) Published Date: 6/11/2025
-
New Carrier® Staged Air Volume SAV™ System Brochure Published Date: 1/24/2015
-
Understanding the AIM Act Published Date: 3/10/2022
-
40RUA Guide Specifications, 44 to 106 kW (12.5 to 30 Nominal Tons) 50 Hz Published Date: 12/2/2024
-
40RUA/40RUS Guide Specifications, 5,000 to 12,000 Nominal Cfm, 12.5 To 30 Nominal Tons Cooling Published Date: 10/9/2025
-
40RU 14-16 Packaged Air-Handling Units with Puron (R-410A) Refrigerant, 50 Hz Published Date: 12/2/2024
-
40RU 14-16 Packaged Air-Handling Units with Puron (R-410A) Refrigerant, 60 Hz Published Date: 4/23/2025
-
40RU 25-30 Packaged Air-Handling Units, 60 Hz, with Puron (R-410A) Refrigerant Published Date: 4/23/2025
-
40RU 25-30 Packaged Air-Handling Units, with Puron (R-410A) Refrigerant, 50 Hz Published Date: 12/2/2024
-
40RFA 07-12, 40RFS 08-12, 40RUA/40RUS 14-30 Packaged Air-Handling Units, 6 to 30 Nominal Tons Published Date: 10/9/2025
-
40RFA 07-12, 40RUA 14-30 Packaged Air-Handling Units with Puron (R-410A) Refrigerant, 21-106 kW, 50 Hz Published Date: 12/2/2024
-
40RUA, 40RUQ, 40RUS 12-30 Ton Packaged Air Handling Horizontal Units with No Heat Family REVIT Files Published Date: 4/23/2019
-
40RUA, 40RUQ, 40RUS 12-30 Ton Packaged Air Handling Vertical Units with Electric Heat Family REVIT Files Published Date: 4/23/2019
-
40RUA, 40RUQ, 40RUS 12-30 Ton Packaged Air Handling Vertical Units with No Heat Family REVIT Files Published Date: 4/23/2019
-
40RUA, 40RUQ, 40RUS 6-10 Ton Packaged Air Handling Horizontal Units with No Heat Family REVIT Files Published Date: 4/23/2019
-
40RUA, 40RUQ, 40RUS 6-10 Ton Packaged Air Handling Vertical Units with Electric Heat Family REVIT Files Published Date: 4/23/2019
-
40RUA, 40RUQ, 40RUS 6-10 Ton Packaged Air Handling Vertical Units with No Heat Family REVIT Files Published Date: 4/23/2019
-
40RUA, 40RUQ, 40RUS 6-30 Ton Packaged Air Handling Horizontal Units with Steam Heat Family REVIT Files Published Date: 4/23/2019
-
40RUA, 40RUQ, 40RUS 6-30 Ton Packaged Air Handling Units with Plenum Family REVIT Files Published Date: 4/23/2019
-
40RUA, 40RUQ, 40RUS 6-30 Ton Packaged Air Handling Vertical Units with Hot Water Heat Family REVIT Files Published Date: 4/23/2019
-
40RUA, 40RUQ, 40RUS 6-30 Ton Packaged Air Handling Vertical Units with Steam Heat Family REVIT Files Published Date: 4/23/2019