AQUASNAP®
30MP
Modular Indoor Water-Cooled/Condenserless Liquid Chiller
with Puron® Refrigerant (R-410A)
15 to 45 nominal tons
30MPA - Condenserless Chiller
30MPW - Packaged Chiller
AquaSnap® 30MP packaged liquid and condenserless chillers feature a compact modular design that makes them ideal for easy replacement, retrofit, or new construction applications.
Performance Features
- ASHRAE 90.1 compliant
- ComfortLink™ microprocessor-based controls
- High-efficiency scroll compressor
- Quiet, reliable operation
- Easy-to-use controls
- Energy management module minimizes chiller energy consumption (factory-installed option or field-installed accessory)
- Scrolling marquee display shows operating parameters in plain language
- Heat recovery capability up to 140°F (60°C)
Reliability Features
- Thermostatic expansion valves
- Hermetic-type filter driers
- Loss of refrigerant charge protection
- Low control voltage (to unit) protection
- Thermal overload protection
- Pressure overload
- Electrical overload through the use of definite-purpose contactors and calibrated, ambient compensated, magnetic trip circuit breakers
- Standard 60 Hz unit listed with ETL and ETL, Canada, and built in accordance with ASME requirements
Maintenance Features
- Over 15 diagnostic functions
- Moisture indicating sight glasses
Installation Features
- Single point electrical connection
- Shipped with R-410A (30MPW ) or nitrogen (30MPA) holding charge
- Fits through standard 36-in. doorway
- Factory-assembled and shipped with complete internal piping and wiring and essential controls and protective devices
- Control power transformer
Standard Warranty
- One year parts and labor
Factory-Installed Options
- Unit-mounted, non-fused disconnect
- Medium temperature brine operation
- EMM (energy management module)
- Sound enclosure panels
- Hot gas bypass
- Non-fused disconnect
- Medium temperature brine
- Mobility package (wheels)
- Condenserless unit
- Height adjustment (leveling) kit
- BACnet Communication
- Digital scroll compressor
- Water manifold piping
Field-Installed Accessories
- EMM (energy management module)
- Sound enclosure panels>
- Hot gas bypass
- Vibration isolators (resilient pads)
- Vibration isolators (springs)
- BACnet translator
- LON (local operating network) translator control
- Mobility package (wheels)
- Condenser water temperature sensors
- Height adjustment (leveling) kit
- Compressor return gas sensor
- Bronze Y strainer
- Navigator™ display module
- Remote enhanced display
- Vicatualir spacer kit (for water manifold piping)
Unit | Capacity | Input
power (kW) |
Evaporator
flow |
Evaporator
pressure drop |
Condenser
flow |
Condenser
pressure drop |
|||||
---|---|---|---|---|---|---|---|---|---|---|---|
Tons | kW | gpm | L/s | Ft of
Water |
kPa | gpm | L/s | Ft of
Water |
kPa | ||
MPW015 | 15.6 | 54.7 | 12.4 | 37.4 | 2.4 | 11.0 | 32.9 | 46.7 | 2.9 | 12.2 | 36.5 |
MPW020 | 20.7 | 72.8 | 15.6 | 49.8 | 3.1 | 14.9 | 44.6 | 62.2 | 3.9 | 16.8 | 50.2 |
MPW030 | 31.0 | 109.1 | 23.6 | 74.5 | 4.7 | 13.6 | 40.7 | 93.1 | 5.9 | 17.1 | 51.1 |
MPW040 | 39.9 | 140.4 | 30.2 | 95.9 | 6.1 | 10.3 | 30.8 | 119.8 | 7.6 | 18.8 | 56.2 |
MPW045 | 46.6 | 163.8 | 35.1 | 111.9 | 7.1 | 12.4 | 37.1 | 139.9 | 8.8 | 16.5 | 49.3 |
Unit | EER | Full load | IPLV | ||
---|---|---|---|---|---|
IkW/Ton | COP | IkW/Ton | COP | ||
MPW015 | 15.1 | 0.795 | 4.43 | 0.564 | 6.24 |
MPW020 | 15.9 | 0.753 | 4.67 | 0.585 | 6.01 |
MPW030 | 15.8 | 0.760 | 4.63 | 0.578 | 6.08 |
MPW040 | 15.9 | 0.756 | 4.65 | 0.560 | 6.28 |
MPW045 | 15.9 | 0.753 | 4.67 | 0.568 | 6.20 |
LEGEND
IPLV = Integrated Part Load Value
AHRI = Air-Conditioning, Heating and Refrigeration Institute
COP = Coefficient of Performance
EER = Energy Efficiency Ratio
IkW = Input Kilowatt
NOTES
1. Rated (60Hz unit) in accordance with AHRI Standard 550/590 at standard rating conditions.
2. Standard rating conditions are as follows:
Cooler Conditions:
Leaving Water Temperature: 44°F (6.7°C)
Flow: 2.4gpm per ton (0.043 L/s per kW)
Condenser Conditions:
Entering Water Temperature: 85°F (29.4°C)
Flow: 3.0gpm per ton (0.054 L/s per kW)
Fouling Factor (Cooler):
0.00010 hr x sq ft x °F per Btuh (0.000018m2 x K per W)
Fouling Factor (Condenser):
0.00025 hr x sq ft x °F per Btuh (0.000044m2 x K per W)
3. IPLV is a single number part load efficiency value calculated from using the efficiency values at 100%, 75%, 50%, and 25% of load when the chiller is operating in AHRI conditions.
4. All data in the above table was generated in Packaged Chiller Builder version 3.39z. Please refer to the most current version of the Packaged Chiller Builder for the most up-to-date data.
5. Contact Carrier for custom ratings.
Performance Features
- ASHRAE 90.1 compliant
- ComfortLink™ microprocessor-based controls
- High-efficiency scroll compressor
- Quiet, reliable operation
- Easy-to-use controls
- Energy management module minimizes chiller energy consumption (factory-installed option or field-installed accessory)
- Scrolling marquee display shows operating parameters in plain language
- Heat recovery capability up to 140°F (60°C)
Reliability Features
- Thermostatic expansion valves
- Hermetic-type filter driers
- Loss of refrigerant charge protection
- Low control voltage (to unit) protection
- Thermal overload protection
- Pressure overload
- Electrical overload through the use of definite-purpose contactors and calibrated, ambient compensated, magnetic trip circuit breakers
- Standard 60 Hz unit listed with ETL and ETL, Canada, and built in accordance with ASME requirements
Maintenance Features
- Over 15 diagnostic functions
- Moisture indicating sight glasses
Installation Features
- Single point electrical connection
- Shipped with R-410A (30MPW ) or nitrogen (30MPA) holding charge
- Fits through standard 36-in. doorway
- Factory-assembled and shipped with complete internal piping and wiring and essential controls and protective devices
- Control power transformer
Standard Warranty
- One year parts and labor
Factory-Installed Options
- Unit-mounted, non-fused disconnect
- Medium temperature brine operation
- EMM (energy management module)
- Sound enclosure panels
- Hot gas bypass
- Non-fused disconnect
- Medium temperature brine
- Mobility package (wheels)
- Condenserless unit
- Height adjustment (leveling) kit
- BACnet Communication
- Digital scroll compressor
- Water manifold piping
Field-Installed Accessories
- EMM (energy management module)
- Sound enclosure panels>
- Hot gas bypass
- Vibration isolators (resilient pads)
- Vibration isolators (springs)
- BACnet translator
- LON (local operating network) translator control
- Mobility package (wheels)
- Condenser water temperature sensors
- Height adjustment (leveling) kit
- Compressor return gas sensor
- Bronze Y strainer
- Navigator™ display module
- Remote enhanced display
- Vicatualir spacer kit (for water manifold piping)
Unit | Capacity | Input
power (kW) |
Evaporator
flow |
Evaporator
pressure drop |
Condenser
flow |
Condenser
pressure drop |
|||||
---|---|---|---|---|---|---|---|---|---|---|---|
Tons | kW | gpm | L/s | Ft of
Water |
kPa | gpm | L/s | Ft of
Water |
kPa | ||
MPW015 | 15.6 | 54.7 | 12.4 | 37.4 | 2.4 | 11.0 | 32.9 | 46.7 | 2.9 | 12.2 | 36.5 |
MPW020 | 20.7 | 72.8 | 15.6 | 49.8 | 3.1 | 14.9 | 44.6 | 62.2 | 3.9 | 16.8 | 50.2 |
MPW030 | 31.0 | 109.1 | 23.6 | 74.5 | 4.7 | 13.6 | 40.7 | 93.1 | 5.9 | 17.1 | 51.1 |
MPW040 | 39.9 | 140.4 | 30.2 | 95.9 | 6.1 | 10.3 | 30.8 | 119.8 | 7.6 | 18.8 | 56.2 |
MPW045 | 46.6 | 163.8 | 35.1 | 111.9 | 7.1 | 12.4 | 37.1 | 139.9 | 8.8 | 16.5 | 49.3 |
Unit | EER | Full load | IPLV | ||
---|---|---|---|---|---|
IkW/Ton | COP | IkW/Ton | COP | ||
MPW015 | 15.1 | 0.795 | 4.43 | 0.564 | 6.24 |
MPW020 | 15.9 | 0.753 | 4.67 | 0.585 | 6.01 |
MPW030 | 15.8 | 0.760 | 4.63 | 0.578 | 6.08 |
MPW040 | 15.9 | 0.756 | 4.65 | 0.560 | 6.28 |
MPW045 | 15.9 | 0.753 | 4.67 | 0.568 | 6.20 |
LEGEND
IPLV = Integrated Part Load Value
AHRI = Air-Conditioning, Heating and Refrigeration Institute
COP = Coefficient of Performance
EER = Energy Efficiency Ratio
IkW = Input Kilowatt
NOTES
1. Rated (60Hz unit) in accordance with AHRI Standard 550/590 at standard rating conditions.
2. Standard rating conditions are as follows:
Cooler Conditions:
Leaving Water Temperature: 44°F (6.7°C)
Flow: 2.4gpm per ton (0.043 L/s per kW)
Condenser Conditions:
Entering Water Temperature: 85°F (29.4°C)
Flow: 3.0gpm per ton (0.054 L/s per kW)
Fouling Factor (Cooler):
0.00010 hr x sq ft x °F per Btuh (0.000018m2 x K per W)
Fouling Factor (Condenser):
0.00025 hr x sq ft x °F per Btuh (0.000044m2 x K per W)
3. IPLV is a single number part load efficiency value calculated from using the efficiency values at 100%, 75%, 50%, and 25% of load when the chiller is operating in AHRI conditions.
4. All data in the above table was generated in Packaged Chiller Builder version 3.39z. Please refer to the most current version of the Packaged Chiller Builder for the most up-to-date data.
5. Contact Carrier for custom ratings.