Skip to main content

Airovision™
39HQ

Air Handler
Custom Double-Wall
Indoor, Outdoor & Hygienic Applications

600 to 48,500 nominal cfm

Carrier's AiroVision 39HQ Central Station Air Handler Units come with 122 different standard sizes. They combine versatility with economical, dependable performance for heating, cooling, ventilation, and VAV (variable air volume) and hygienic applications.

The construction of the Carrier air handling units consists of a frame and panels. Profiled 1-mm thick casing sides of galvanized and coated steel plates ensure a rigid and lightweight frame. The frame holds a 60-mm dual-skin casing wall with panels, doors, inspection hatches and removable center posts. The casing wall construction comes in several versions of steel plate thicknesses, material types and insulation materials used.

The characteristic of the casing wall construction must be established in accordance with EN 1886, based on measurements carried out on a model box

  • Mechanical strength class D1
  • Casing air leakage class L2
  • Filter bypass leakage :
    • F9 (front withdrawal filter)
    • F9 (slide withdrawal filter)
    • F7 (slide withdrawal filter -standard)
  • Thermal transmittance class T2
  • Thermal bridging class TB2
  • Acoustics insulation
  • Carrier’s AiroVision® software makes selecting and optimizing the 39HQ air handler easy.
  • Country of origin: Turkey
  • Air-flows ranging from 2000 m3/hr to 125,000 m3/hr
  • Double skin panel construction, excellent heat preservation
  • Galvanized steel construction
  • The standard casing wall construction GP080 consists of 0.8 mm internal and external plating with mineral wool (glass wool) in between
  • Parallel and opposed blade dampers on mixing boxes
  • Horizontal and vertical draw-thru arrangements
  • Multiple filtration from pleated to HEPA filters
  • Chilled water, hot water, direct expansion (DX)
  • Coils fabricated and tested in accordance with ASHRAE/ANSI 15 Safety Code for Mechanical Refrigeration (latest edition).
  • Dual refrigerant circuits.
  • Single skin drain pan insulated with 60 mm panels from all sides.
  • Various coil face areas, fin densities, and circuiting arrangements
  • Forward, backward, aerofoil and plug fan
  • Multiple fan options
  • Electric preheat available over a wide kW range
  • EN 1886 “Air handling units – Mechanical performance”
  • EN 13053 “Air handling units – Ratings and performance for units, components and sections Reliability Features”
  • Fan performance tested and certified to DIN and AMCA Standard.
  • Standard IE1 fan motor manufactured to conform IEC Standard.
  • ARI 1060 and Eurovent Certified Energy Recovery Wheels
  • Special stainless steel construction and other features for hygienic applications 
  • Units may be mounted in ceilings, closets, attics, etc.
  • Casing can be broken-down to individual panels and frame members
  • All service may be done through large, removable or hinged panels
  • Horizontal or vertical arrangements
  • Stainless steel casing
  • Filter kits
  • Pre filter
  • HEPA filter
  • Stainless steel condensate drain pan
  • Coil type options: 
    • Chilled water coils
    • Hot water coils
    • DX coils
    • Steam coils
    • Electric heater
    • Copper coils
  • Coil face area, fin density, and circuiting arrangement options
  • Blower motor and belt drive package
  • Heat wheel
  • Run around coils
  • Plate Type heat exchangers 
  • Marine light installation kit
  • Viewport installation kit
  • Factory supplied VFD
  • Special stainless steel construction and other features for hygienic applications 
  • Attenuator
  • Ultraviolet band C (UV-C) germicidal lamps
  • Measuring gages
Model Nominal Air Flow * cfm Dimensions (mm)**
Width  Height
39HQ  0404 1,120 738 738
39HQ  0504 1,565 898 738
39HQ  0604 1,990 1058 738
39HQ 0606 3,195 1058 1058
39HQ  0704 2,415 1218 738
39HQ 0706 3,895 1218 1058
39HQ  0804 2,860 1378 738
39HQ 0806 4,575 1378 1058
39HQ 0808 6,310 1378 1378
39HQ 0906 5,295 1538 1058
39HQ 0908 7,305 1538 1378
39HQ 1006 5,970 1698 1058
39HQ 1008 8,260 1698 1378
39HQ 1010 10,165 1698 1698
39HQ 1106 6,670 1858 1058
39HQ 1108 9,210 1858 1378
39HQ 1110 11,330 1858 1698
39HQ 1206 7,390 2018 1058
39HQ 1208 10,165 2018 1378
39HQ 1210 12,600 2018 1698
39HQ 1212 15,350 2018 2018
39HQ 1308 11,120 2178 1378
39HQ 1310 13,765 2178 1698
39HQ 1312 16,730 2178 2018
39HQ 1408 12,070 2338 1378
39HQ 1410 15,035 2338 1698
39HQ 1412 18,210 2338 2018
39HQ 1414 21,390 2338 2338
39HQ 1608 13,975 2658 1378
39HQ 1610 17,365 2658 1698
39HQ 1612 21,175 2658 2018
39HQ 1614 24,990 2658 2338
39HQ 1616 28,590 2658 2658
39HQ 1810 19,800 2978 1698
39HQ 1812 24,140 2978 2018
39HQ 1814 28,375 2978 2338
39HQ 1816 32,610 2978 2658
39HQ 2010 22,235 3298 1698
39HQ 2012 27,100 3298 2018
39HQ 2014 31,975 3298 2338
39HQ 2016 36,850 3298 2658
39HQ 2212 30,070 3618 2018
39HQ 2214 35,365 3618 2338
39HQ 2216 40,870 3618 2658
39HQ 2412 33,035 3938 2018
39HQ 2414 38,965 3938 2338
39HQ 2416 44,895 3938 2658
39HQ 2418 49,765 3938 2978

*Airflow is based upon 500ft/min face velocity.
**Airway length is variable upon different component arrangements. Contact local Carrier Office for individual airway length of components.

  • Air-flows ranging from 2000 m3/hr to 125,000 m3/hr
  • Double skin panel construction, excellent heat preservation
  • Galvanized steel construction
  • The standard casing wall construction GP080 consists of 0.8 mm internal and external plating with mineral wool (glass wool) in between
  • Parallel and opposed blade dampers on mixing boxes
  • Horizontal and vertical draw-thru arrangements
  • Multiple filtration from pleated to HEPA filters
  • Chilled water, hot water, direct expansion (DX)
  • Coils fabricated and tested in accordance with ASHRAE/ANSI 15 Safety Code for Mechanical Refrigeration (latest edition).
  • Dual refrigerant circuits.
  • Single skin drain pan insulated with 60 mm panels from all sides.
  • Various coil face areas, fin densities, and circuiting arrangements
  • Forward, backward, aerofoil and plug fan
  • Multiple fan options
  • Electric preheat available over a wide kW range
  • EN 1886 “Air handling units – Mechanical performance”
  • EN 13053 “Air handling units – Ratings and performance for units, components and sections Reliability Features”
  • Fan performance tested and certified to DIN and AMCA Standard.
  • Standard IE1 fan motor manufactured to conform IEC Standard.
  • ARI 1060 and Eurovent Certified Energy Recovery Wheels
  • Special stainless steel construction and other features for hygienic applications 
  • Units may be mounted in ceilings, closets, attics, etc.
  • Casing can be broken-down to individual panels and frame members
  • All service may be done through large, removable or hinged panels
  • Horizontal or vertical arrangements
  • Stainless steel casing
  • Filter kits
  • Pre filter
  • HEPA filter
  • Stainless steel condensate drain pan
  • Coil type options: 
    • Chilled water coils
    • Hot water coils
    • DX coils
    • Steam coils
    • Electric heater
    • Copper coils
  • Coil face area, fin density, and circuiting arrangement options
  • Blower motor and belt drive package
  • Heat wheel
  • Run around coils
  • Plate Type heat exchangers 
  • Marine light installation kit
  • Viewport installation kit
  • Factory supplied VFD
  • Special stainless steel construction and other features for hygienic applications 
  • Attenuator
  • Ultraviolet band C (UV-C) germicidal lamps
  • Measuring gages
Model Nominal Air Flow * cfm Dimensions (mm)**
Width  Height
39HQ  0404 1,120 738 738
39HQ  0504 1,565 898 738
39HQ  0604 1,990 1058 738
39HQ 0606 3,195 1058 1058
39HQ  0704 2,415 1218 738
39HQ 0706 3,895 1218 1058
39HQ  0804 2,860 1378 738
39HQ 0806 4,575 1378 1058
39HQ 0808 6,310 1378 1378
39HQ 0906 5,295 1538 1058
39HQ 0908 7,305 1538 1378
39HQ 1006 5,970 1698 1058
39HQ 1008 8,260 1698 1378
39HQ 1010 10,165 1698 1698
39HQ 1106 6,670 1858 1058
39HQ 1108 9,210 1858 1378
39HQ 1110 11,330 1858 1698
39HQ 1206 7,390 2018 1058
39HQ 1208 10,165 2018 1378
39HQ 1210 12,600 2018 1698
39HQ 1212 15,350 2018 2018
39HQ 1308 11,120 2178 1378
39HQ 1310 13,765 2178 1698
39HQ 1312 16,730 2178 2018
39HQ 1408 12,070 2338 1378
39HQ 1410 15,035 2338 1698
39HQ 1412 18,210 2338 2018
39HQ 1414 21,390 2338 2338
39HQ 1608 13,975 2658 1378
39HQ 1610 17,365 2658 1698
39HQ 1612 21,175 2658 2018
39HQ 1614 24,990 2658 2338
39HQ 1616 28,590 2658 2658
39HQ 1810 19,800 2978 1698
39HQ 1812 24,140 2978 2018
39HQ 1814 28,375 2978 2338
39HQ 1816 32,610 2978 2658
39HQ 2010 22,235 3298 1698
39HQ 2012 27,100 3298 2018
39HQ 2014 31,975 3298 2338
39HQ 2016 36,850 3298 2658
39HQ 2212 30,070 3618 2018
39HQ 2214 35,365 3618 2338
39HQ 2216 40,870 3618 2658
39HQ 2412 33,035 3938 2018
39HQ 2414 38,965 3938 2338
39HQ 2416 44,895 3938 2658
39HQ 2418 49,765 3938 2978

*Airflow is based upon 500ft/min face velocity.
**Airway length is variable upon different component arrangements. Contact local Carrier Office for individual airway length of components.