i-Vu® Open Router
CIV-OR

Network & Integration Device

BACnet®/IP routing with a subnetwork of BACnet MS/TP controllers. Increases the capacity of the i-Vu® Building Automation System.

The i-Vu Open Router provides BACnet routing capabilities between the i-Vu Building Automation System backbone (BACnet/IP), and a subnetwork of Open controllers (BACnet MS/TP). It connects directly to the Ethernet LAN and provides the i-Vu web server with access to the entire building network.

The i-Vu Open Router also increases the capacity of the i-Vu Building Automation System, allowing individual BACnet MS/TP networks (with up to 60 Open controllers each), to be connected together via the i-Vu Building Automation System backbone.


carrier-bacnet-international-member
carrier-bacnet-testing-laboratories
Communication Ports Port E1:10/100 BaseT Ethernet port for LAN and BACnet IP communications
Port S1 (BACnet MS/TP): EIA-485 port for BACnet MS/TP communications (9600 bps, 19.2 kbps, 38.4 kbps and 76.8 kbps)
Port S2 (Router Config): EIA-232 port for Router Configuration using HyperTerminal (115.2 kbps)
Local Access Port: For system start-up and troubleshooting or Router Configuration (115.2 kbps) or Router Configuration using HyperTerminal (115.2 kbps)
Protection Incoming power and network connections are protected by non-replaceable internal solidstate polyswitches that reset themselves when the condition that causes a fault returns to normal. The power, network, input, and output connections are also protected against voltage transient and surge events.
Real Time Clock Battery-backed real time clock
Battery 10-year Lithium CR123A battery provides a maximum of 720 hours of time retention during power outages. To conserve battery life, battery backup turns off after a specified number of days defined in the module driver.
Status Indicators LED status indicators for BACnet MS/TP communication, Ethernet port communication, and low battery status. 7-segment status display for running, error and power status.
Controller Addressing Rotary DIP switches set address of Router.
Listed By UL-916 (Canadian Std C22.2 No. 205-M1983), CE, FCC Part 15-Subpart B-Class A
Environmental Operating Range Operating: 0° to 140°F (-18° to 60°C), 10-90% relative humidity, non-condensing
Storage: -24°F to 140°F (-30° to 60°C), 10-90% relative humidity, non-condensing
Power Requirements 24VAC +/- 10%, 50-60Hz
24VA power consumption
26VDC (25V min, 30V max)
Single Class 2 source only, 100VA or less
Physical Rugged aluminum cover and removable screw terminal blocks.
Dimensions Length: 7-1/2” (19.1 cm)
Width: 11-3/8” (28.9 cm)
Depth: 1-1/2” (3.8 cm)
Weight: 1.4 lbs. (.64 kg)
Communication Ports Port E1:10/100 BaseT Ethernet port for LAN and BACnet IP communications
Port S1 (BACnet MS/TP): EIA-485 port for BACnet MS/TP communications (9600 bps, 19.2 kbps, 38.4 kbps and 76.8 kbps)
Port S2 (Router Config): EIA-232 port for Router Configuration using HyperTerminal (115.2 kbps)
Local Access Port: For system start-up and troubleshooting or Router Configuration (115.2 kbps) or Router Configuration using HyperTerminal (115.2 kbps)
Protection Incoming power and network connections are protected by non-replaceable internal solidstate polyswitches that reset themselves when the condition that causes a fault returns to normal. The power, network, input, and output connections are also protected against voltage transient and surge events.
Real Time Clock Battery-backed real time clock
Battery 10-year Lithium CR123A battery provides a maximum of 720 hours of time retention during power outages. To conserve battery life, battery backup turns off after a specified number of days defined in the module driver.
Status Indicators LED status indicators for BACnet MS/TP communication, Ethernet port communication, and low battery status. 7-segment status display for running, error and power status.
Controller Addressing Rotary DIP switches set address of Router.
Listed By UL-916 (Canadian Std C22.2 No. 205-M1983), CE, FCC Part 15-Subpart B-Class A
Environmental Operating Range Operating: 0° to 140°F (-18° to 60°C), 10-90% relative humidity, non-condensing
Storage: -24°F to 140°F (-30° to 60°C), 10-90% relative humidity, non-condensing
Power Requirements 24VAC +/- 10%, 50-60Hz
24VA power consumption
26VDC (25V min, 30V max)
Single Class 2 source only, 100VA or less
Physical Rugged aluminum cover and removable screw terminal blocks.
Dimensions Length: 7-1/2” (19.1 cm)
Width: 11-3/8” (28.9 cm)
Depth: 1-1/2” (3.8 cm)
Weight: 1.4 lbs. (.64 kg)