Skip to main content

Airovision™
39HQM

Air Handler
Custom Double-Wall
Indoor, Outdoor Application

600 to 48,500 nominal cfm

Carrier's AiroVision 39HQM Central Station Air Handler Units come with 64 different standard sizes. They combine versatility with economical, dependable performance for heating, cooling, ventilation, and VAV (variable air volume) applications.

The construction of the Carrier air handling units consists of a frame and panels. Profiled 1.0-mm thick casing sides of galvanized and coated steel plates ensure a rigid and lightweight frame. The frame holds a 60-mm dual-skin casing wall with panels, doors, inspection hatches and removable center posts. The casing wall construction comes in several versions of steel plate thicknesses, material types and insulation materials used.

The characteristic of the casing wall construction must be established in accordance with EN 1886, based on measurements carried out on a model box

  • Mechanical strength class D1
  • Casing air leakage class L1
  • Filter by-pass leakage class F7
  • Thermal transmittance class T2
  • Thermal bridging class TB2
  • Acoustics insulation
  • Carrier’s AiroVision® software makes selecting and optimizing the 39HQM air handler easy.
  • Country of origin: Saudi Arabia
  • Air-flows ranging from 1100 m3/hr to 108,000 m3/hr
  • Double skin panel construction, excellent heat preservation
  • Galvanized steel construction
  • CFC-Free Polyurethane with 40kg/m3 density and K value of 0.19 W/M ºC K
  • Parallel and opposed blade dampers on mixing boxes
  • Horizontal and vertical draw-thru arrangements
  • Multiple filtration from pleated to HEPA filters
  • Chilled water, hot water, direct expansion (DX)
  • Dual refrigerant circuits for DX coil
  • Coils fabricated and tested in accordance with ASHRAE/ANSI 15 Safety Code for Mechanical Refrigeration (latest edition).
  • Single skin drain pan insulated with 60 mm panels from all sides.
  • Various coil face areas, fin densities, and circuiting arrangements
  • Forward, backward,aerofoil and plug fan
  • Multiple fan options
  • Electric preheat available over a wide kW range  
  • EN 1886 “Air handling units – Mechanical performance”
  • EN 13053 “Air handling units – Ratings and performance for units, components and sections Reliability Features
  • Fan performance tested and certified to DIN and AMCA Standard.
  • Standard IE1 fan motor manufactured to conform IEC Standard (optional IE2 & IE3 motors with UL listed)  
  • ARI 1060 and Eurovent Certified Energy Recovery Wheels
  • Ultraviolet band C (UV-C) germicidal lamps
  • Marine lights and viewports for interior component inspection
  • All service may be done through large, removable or hinged panels
  • Units may be mounted in ceilings, closets, attics, etc.
  • Casing can be broken-down to individual panels and frame members
  • Pre filter
  • HEPA filter
  • Coil type options:
    • Chilled water coils
    • Hot water coils
    • DX coils
    • Steam coils
  • Electric heaters
  • Coil face area, fin density, and circuiting arrangement options
  • Stainless steel condensate drain pan
  • Blower motor and belt drive package
  • Heat wheel
  • Run around coils
  • Plate type heat exchangers
  • Marine light installation kit
  • Viewport installation kit
  • Factory supplied VFD
  • Electrical heater
  • Attenuator
  • Ultraviolet band-C (UV-C) germicidal lamps
Model  Nominal Air Flow *cfm Dimensions mm)**
Width  Height
39HQM 0404 1,100 740 802
39HQM 0504 1,525 900 802
39HQM 0604 1,950 1060 802
39HQM 0606 3,175 1060 1122
39HQM 0704 2,370 1220 802
39HQM 0706 3,855 1220 1122
39HQM 0804 2,795 1380 802
39HQM 0806 4,510 1380 1122
39HQM 0808 6,245 1380 1442
39HQM 0906 5,230 1540 1122
39HQM 0908 7,070 1540 1442
39HQM 1006 5,930 1700 1122
39HQM 1008 8,045 1700 1442
39HQM 1010 10,270 1700 1762
39HQM 1106 6,625 1860 1122
39HQM 1108 9,000 1860 1442
39HQM 1110 11,500 1860 1762
39HQM 1206 7,325 2020 1122
39HQM 1208 9,995 2020 1442
39HQM 1210 12,745 2020 1762
39HQM 1212 15,500 2020 2082
39HQM 1308 10,945 2180 1442
39HQM 1310 13,975 2180 1762
39HQM 1312 17,045 2180 2082
39HQM 1408 11,900 2340 1442
39HQM 1410 15,245 2340 1762
39HQM 1412 18,295 2340 2082
39HQM 1508 12,895 2500 1442
39HQM 1510 16,475 2500 1762
39HQM 1512 19,800 2500 2082
39HQM 1608 13,825 2660 1442
39HQM 1610 17,680 2660 1762
39HQM 1612 21,300 2660 2082
39HQM 1710 19,090 2820 1762
39HQM 1712 23,295 2820 2082
39HQM 1810 20,000 2980 1762
39HQM 1812 24,290 2980 2082
39HQM 1814 28,695 2980 2402
39HQM 1816 33,035 2980 2722
39HQM 1912 26,300 3140 2082
39HQM 1914 30,920 3140 2402
39HQM 1916 35,680 3140 2722
39HQM 2012 27,285 3300 2082
39HQM 2014 32,185 3300 2402
39HQM 2214 36,255 3620 2402
39HQM 2414 39,880 3940 2402
39HQM 2416 45,875 3940 2722
39HQM 2514 41,655 4100 2402
39HQM 2516 47,860 4100 2722

*Airflow is based upon 500ft/min face velocity.
**Airway length is variable upon different component arrangements. Contact local Carrier Office for individual airway length of components.

  • Air-flows ranging from 1100 m3/hr to 108,000 m3/hr
  • Double skin panel construction, excellent heat preservation
  • Galvanized steel construction
  • CFC-Free Polyurethane with 40kg/m3 density and K value of 0.19 W/M ºC K
  • Parallel and opposed blade dampers on mixing boxes
  • Horizontal and vertical draw-thru arrangements
  • Multiple filtration from pleated to HEPA filters
  • Chilled water, hot water, direct expansion (DX)
  • Dual refrigerant circuits for DX coil
  • Coils fabricated and tested in accordance with ASHRAE/ANSI 15 Safety Code for Mechanical Refrigeration (latest edition).
  • Single skin drain pan insulated with 60 mm panels from all sides.
  • Various coil face areas, fin densities, and circuiting arrangements
  • Forward, backward,aerofoil and plug fan
  • Multiple fan options
  • Electric preheat available over a wide kW range  
  • EN 1886 “Air handling units – Mechanical performance”
  • EN 13053 “Air handling units – Ratings and performance for units, components and sections Reliability Features
  • Fan performance tested and certified to DIN and AMCA Standard.
  • Standard IE1 fan motor manufactured to conform IEC Standard (optional IE2 & IE3 motors with UL listed)  
  • ARI 1060 and Eurovent Certified Energy Recovery Wheels
  • Ultraviolet band C (UV-C) germicidal lamps
  • Marine lights and viewports for interior component inspection
  • All service may be done through large, removable or hinged panels
  • Units may be mounted in ceilings, closets, attics, etc.
  • Casing can be broken-down to individual panels and frame members
  • Pre filter
  • HEPA filter
  • Coil type options:
    • Chilled water coils
    • Hot water coils
    • DX coils
    • Steam coils
  • Electric heaters
  • Coil face area, fin density, and circuiting arrangement options
  • Stainless steel condensate drain pan
  • Blower motor and belt drive package
  • Heat wheel
  • Run around coils
  • Plate type heat exchangers
  • Marine light installation kit
  • Viewport installation kit
  • Factory supplied VFD
  • Electrical heater
  • Attenuator
  • Ultraviolet band-C (UV-C) germicidal lamps
Model  Nominal Air Flow *cfm Dimensions mm)**
Width  Height
39HQM 0404 1,100 740 802
39HQM 0504 1,525 900 802
39HQM 0604 1,950 1060 802
39HQM 0606 3,175 1060 1122
39HQM 0704 2,370 1220 802
39HQM 0706 3,855 1220 1122
39HQM 0804 2,795 1380 802
39HQM 0806 4,510 1380 1122
39HQM 0808 6,245 1380 1442
39HQM 0906 5,230 1540 1122
39HQM 0908 7,070 1540 1442
39HQM 1006 5,930 1700 1122
39HQM 1008 8,045 1700 1442
39HQM 1010 10,270 1700 1762
39HQM 1106 6,625 1860 1122
39HQM 1108 9,000 1860 1442
39HQM 1110 11,500 1860 1762
39HQM 1206 7,325 2020 1122
39HQM 1208 9,995 2020 1442
39HQM 1210 12,745 2020 1762
39HQM 1212 15,500 2020 2082
39HQM 1308 10,945 2180 1442
39HQM 1310 13,975 2180 1762
39HQM 1312 17,045 2180 2082
39HQM 1408 11,900 2340 1442
39HQM 1410 15,245 2340 1762
39HQM 1412 18,295 2340 2082
39HQM 1508 12,895 2500 1442
39HQM 1510 16,475 2500 1762
39HQM 1512 19,800 2500 2082
39HQM 1608 13,825 2660 1442
39HQM 1610 17,680 2660 1762
39HQM 1612 21,300 2660 2082
39HQM 1710 19,090 2820 1762
39HQM 1712 23,295 2820 2082
39HQM 1810 20,000 2980 1762
39HQM 1812 24,290 2980 2082
39HQM 1814 28,695 2980 2402
39HQM 1816 33,035 2980 2722
39HQM 1912 26,300 3140 2082
39HQM 1914 30,920 3140 2402
39HQM 1916 35,680 3140 2722
39HQM 2012 27,285 3300 2082
39HQM 2014 32,185 3300 2402
39HQM 2214 36,255 3620 2402
39HQM 2414 39,880 3940 2402
39HQM 2416 45,875 3940 2722
39HQM 2514 41,655 4100 2402
39HQM 2516 47,860 4100 2722

*Airflow is based upon 500ft/min face velocity.
**Airway length is variable upon different component arrangements. Contact local Carrier Office for individual airway length of components.