Skip to main content

AquaForce®
30XA

Air-Cooled Liquid Chiller
with R-134a Refrigerant

80 to 501 nominal tons
140 to 350 nominal tons with Greenspeed® Intelligence

AquaForce 30XA with Greenspeed® Intelligence chillers were designed from the ground up to meet the efficiency demands of today and the future by providing premium air-cooled chiller packages for contractors, consulting engineers and building owners. Value-added features include rotary screw compression, R-134a HFC refrigerant, a quiet AeroAcoustic™ fan system, easy to use ComfortLink™ controls, microchannel condenser coil technology, and an optional integrated hydronic pump package with or without VFD.

Performance Features

  • Full-load EER values up to 10.9 and IPLV values up to 15.5
  • ASHRAE 90.1 compliant / AHRI certified
  • Operation from -20 F to 125°F ambient conditions
  • High-efficiency screw compressors
  • Standard uncoated or optional e-coated Novation® microchannel heat exchanger (MCHX) condenser coils
  • Hydronic pump package, available with or without VFD on sizes 090-160
  • Touch Pilot™ display with color touch screen with trending capability and web-based connection

Reliability Features

  • ASME constructed evaporators / ETL (and ETL Canada) listed
  • Heavy-gauge galvanized steel frame
  • Security grilles and Hail guards/Privacy screen choices
  • Low ambient head pressure control
  • Coil corrosion coatings available on all coil types
  • High short circuit current rating
  • EXV (Electronic expansion valve)

Maintenance Features

  • Over 15 diagnostic functions
  • Permanently lubricated fan motor bearings
  • Compressor suction service valves
  • Microchannel condenser coils with inherent corrosion resistance and offering simplified cleaning
  • Unit-mounted, non-fused disconnect
  • Remote service port for easier machine diagnostics

Installation Features

  • Factory charged with R-134a refrigerant
  • GFI (ground fault interrupter) convenience outlet (factory-installed option or field-installed accessory)
  • Remote cooler kit (field-installed accessory)
  • Single or dual-point electrical connections available (factory-installed option)
  • Control transformer (factory-installed option)
  • Structurally robust base
  • Circuit setter provided with optional pump package (factory-installed option)

Standard Warranty

  • 3 year coil parts only on Novation microchannel heat exchanger
  • One year from start-up or 18 months from shipment limited warranty
  • Extended warranties available

Factory-Installed Options

  • Service option
  • Condenser coil trim panels
  • Full end screen
  • Hydronic pump package with or without VFD (sizes 090-160)
  • Condenser coil options:
    • Microchannel Heat Exchanger:
      • Non-coated
      • E-coated
    • Aluminum fins:
      • Non-coated
      • Pre-coated
      • E-coated
    • Copper fins:
      • Non-coated
      • E-coated
  • Non-fused disconnect
  • Security grilles
  • Energy Management Module
  • Compressor sound reduction enclosures
  • Compressor suction service valve
  • Condenser coil upper hail guards
  • BACnet™ communication
  • BACnet™ translator control
  • LON (local operating network) translator control
  • Low ambient temperature head pressure control
  • Single or dual-point electrical connection
  • High ambient temperature option
  • Touch Pilot™ display
  • Navigator™ display
  • DX cooler
  • Minus-one-pass cooler (flooded cooler only)
  • Plus-one-pass cooler (flooded cooler only)
  • Control transformer
  • Suction line insulation
  • High short circuit current rating

Field-Installed Accessories

  • Security grilles
  • Condenser coil full hail guards
  • Navigator™ display
  • GFI convenience outlet
  • Energy Management Module
  • LON (local operating network) translator control
  • BACnet™ translator control
  • Remote service port
  • Remote cooler
  • Condenser coil trim panels
  • Dual-chiller accessory kit
  • External pump control

ARI Capacity Ratings for Units with AL/CU Condenser Coils (Sizes 80-501)

Size Capacity Total power (kW) Full load IPLV Cooler flow rate Cooler pressure drop
tons kW EER COP EER COP GPM L/s ft wg kPa
80 75.6 265.9 91.6 9.9 2.9 14.2 4.2 181.3 11.4 11.7 34.9
90 84.8 298.2 95.1 10.7 3.1 14.6 4.3 203.4 12.8 11.4 34
100 93.9 330.2 107.8 10.5 3.1 15 4.4 225.4 14.2 13.7 40.9
110 102.4 360.1 118.6 10.4 3 15.2 4.4 245.8 15.5 13.9 41.5
120 110.7 389.3 129.5 10.3 3 15.2 4.4 265.7 16.8 11.9 35.5
140 132.8 467 148.7 10.7 3.1 14.4 4.2 318.8 20.1 13.3 39.7
160 152.3 535.6 173 10.6 3.1 14.8 4.3 365.5 23.1 13.1 39.1
180 171.3 602.4 192.1 10.7 3.1 14.3 4.2 411.1 25.9 15.5 46.2
200 194 682.3 217.2 10.7 3.1 14.8 4.3 465.6 29.4 13.2 39.4
220 211.7 744.5 239.6 10.6 3.1 14.5 4.2 508 32 15.5 46.2
240 228.1 802.2 264.1 10.4 3 14.8 4.3 547.5 34.5 17.8 53.1
260 250.9 882.4 281.7 10.7 3.1 14.3 4.2 602.2 38 10.3 30.7
280 268.5 944.3 301.2 10.7 3.1 14.3 4.2 644.3 40.6 11.6 34.6
300 287.5 1011.1 326.3 10.6 3.1 14.9 4.4 690 43.5 13.1 39.1
325 306.6 1078.3 347.1 10.6 3.1 14.3 4.2 735.9 46.4 13.5 40.3
350 324.1 1139.8 374.8 10.4 3 14.4 4.2 777.7 49.1 14.9 44.4
400 383.6 1349.1 449.4 10.2 3 14.8 4.3 920.7 58.1 10.4 31
401 396.3 1393.9 464 10.2 3 13.4 3.9 951.2 59.8 20.8 61.6
450 426.7 1500.6 509.2 10.1 2.9 14.1 4.1 1024.1 64.6 10.1 30.1
451 435.6 1532.2 503.9 10.4 3 13.6 4 1045.5 65.7 25.3 75.1
476 459.2 1615 554.3 9.9 2.9 14 4.1 1102 69.3 22.6 67.1
500 458 1610.7 549.1 10 2.9 14.3 4.2 1099.2 69.3 12.1 36.1
501 494.1 1737.8 580 10.2 3 13.8 4.1 1185.8 74.6 26.1 77.6

ARI Capacity Ratings for Units with MCHX Condenser Coils (Sizes 80-501)

Size Capacity Total power (kW) Full Load IPLV Cooler flow rate Cooler pressure drop
Tons kW EER COP EER COP GPM L/s ft wg kPa
80 75.8 266.6 90.1 10.1 3 14.5 4.2 182 11.5 11.8 35.2
90 85.2 299.6 93.4 10.9 3.2 14.8 4.3 204.5 12.9 11.5 34.3
100 94.4 332 105.7 10.7 3.1 15.3 4.5 226.7 14.3 13.9 41.5
110 103 362.2 116.4 10.6 3.1 15.4 4.5 247.2 15.6 14.1 42.1
120 111.4 391.8 127.2 10.5 3.1 15.5 4.5 267.4 16.9 12 35.8
140 133.4 469.1 146.4 10.9 3.2 14.7 4.3 320.1 20.2 13.4 40
160 153.1 538.4 170.1 10.8 3.2 15 4.4 367.3 23.2 13.2 39.4
180 172 604.9 189.2 10.9 3.2 14.5 4.2 412.8 26 15.6 46.5
200 194.9 685.4 213.7 10.9 3.2 15.1 4.4 467.8 29.5 13.3 39.7
220 212.7 748 235.7 10.8 3.2 14.7 4.3 510.4 32.2 15.7 46.8
240 229.2 806.1 260.1 10.6 3.1 15 4.4 550.1 34.7 18 53.7
260 251.7 885.2 278.8 10.8 3.2 14.4 4.2 604 38.1 10.3 30.7
280 269.3 947.1 298 10.8 3.2 14.5 4.2 646.3 40.8 11.6 34.6
300 288.3 1013.9 323.3 10.7 3.1 15 4.4 691.8 43.6 13.2 39.4
325 307.1 1080 344.8 10.7 3.1 14.4 4.2 737.1 46.5 13.6 40.6
350 324.5 1141.2 372.7 10.5 3.1 14.5 4.3 778.8 49.1 15 44.7
400 385 1354 444.1 10.4 3 14.9 4.4 924 58.3 10.5 31.3
401 396.8 1395.7 462 10.3 3 13.5 4 952.4 59.9 20.8 61.8
450 427.6 1503.8 505.5 10.2 3 14.2 4.2 1026.3 64.7 10.1 30.1
451 436.2 1534.1 501.7 10.4 3.1 13.8 4 1046.8 65.8 25.4 75.3
476 459.8 1617 552 10 2.9 14.1 4.1 1103.4 69.4 22.7 67.2
500 459.1 1614.6 544.8 10.1 3 14.4 4.2 1101.8 69.5 12.2 36.4
501 494.7 1740 577.3 10.3 3 14 4.1 1187.4 74.7 26.2 77.8

Legend:
AL - Aluminum
COP - Coefficient of Performance
CU - Copper
EER - Energy Efficiency Ratio
IPLV - Integrated Part Load Value
MCHX - Microchannel Heat Exchanger

Notes:

  1. Rated in accordance with AHRI Standard 550/590 at standard rating conditions.
  2. Standard rating conditions are as follows:
    Cooler Conditions:
        Leaving water temperature: 44 F (6.7 C)
        Flow rate: 2.4 gpm/ton (0.043 l/s per kW)
    Fouling Factor:
        0.00010 hr x sq ft °F/Btu (0.000018 m2 x °C/W)
    Condenser Conditions:
        Entering air temperature: 95 F (35 C)
  3. Units configured with no suction service valve or suction line insultation.
  4. Unit performances will vary depending on the options configured. All data in the above tables was generated in Packaged Chiller Builder version 3.49a. Refer to the latest version of the Packaged Chiller Builder for the most up-to-date data.

Weights & Dimensions (Sizes 80-501)

Size Operating weight (lb) Dimensions (ft-in)
AL/CU Coil CU/CU Coil MCHX Coil Length Width Height
80 7674 8398 7234 11-10 7-4 3/4 7-6 7/16
82 7831 8555 7391 11-10 7-4 3/4 7-6 7/16
90 9959 10924 9382 15-9 7-4 3/4 7-6 7/16
92 10083 11048 9506 15-9 7-4 3/4 7-6 7/16
100 10186 11151 9603 15-9 7-4 3/4 7-6 7/16
102 10310 11275 9727 15-9 7-4 3/4 7-6 7/16
110 10326 11291 9738 15-9 7-4 3/4 7-6 7/16
112 10563 11528 9975 15-9 7-4 3/4 7-6 7/16
120 10471 11436 9877 15-9 7-4 3/4 7-6 7/16
122 10681 11646 10087 15-9 7-4 3/4 7-6 7/16
140 12760 13966 12023 19-8 7-4 3/4 7-6 7/16
142 13217 14423 12480 19-8 7-4 3/4 7-6 7/16
160 13003 14209 12255 19-8 7-4 3/4 7-6 7/16
162 13429 14635 12681 19-8 7-4 3/4 7-6 7/16
180 13590 15037 12699 23-7 7-4 3/4 7-6 7/16
182 13935 15382 13044 23-7 7-4 3/4 7-6 7/16
200 13712 15159 12810 23-7 7-4 3/4 7-6 7/16
202 14014 15461 13112 23-7 7-4 3/4 7-6 7/16
220 14727 16295 13748 27-6 7-4 3/4 7-6 7/16
222 15071 16639 14092 27-6 7-4 3/4 7-6 7/16
240 14887 16455 13897 27-6 7-4 3/4 7-6 7/16
242 15231 16799 14241 27-6 7-4 3/4 7-6 7/16
260 16853 18662 15720 31-5 7-4 3/4 7-6 7/16
262 17055 18864 15922 31-5 7-4 3/4 7-6 7/16
280 17022 18831 15878 31-5 7-4 3/4 7-6 7/16
282 17224 19033 16080 31-5 7-4 3/4 7-6 7/16
300 17362 19292 16141 31-5 7-4 3/4 7-6 7/16
302 17834 19764 16613 31-5 7-4 3/4 7-6 7/16
325 18834 21005 17467 36-4 7-4 3/4 7-6 7/16
327 19306 21477 17939 36-4 7-4 3/4 7-6 7/16
350 19040 21211 17659 36-4 7-4 3/4 7-6 7/16
352 19512 21683 18131 36-4 7-4 3/4 7-6 7/16
400 24578 26990 23038 39-3 7-4 3/4 7-6 7/16
401 22690 25102 20782 39-3 7-4 3/4 7-6 7/16
450 26600 29254 24901 43-2 7-4 3/4 7-6 7/16
451 23421 26075 21324 43-2 7-4 3/4 7-6 7/16
476 27520 30174 25422 43-2 7-4 3/4 7-6 7/16
500 26894 29547 25167 43-2 7-4 3/4 7-6 7/16
501 29883 33019 27403 51-3 7-4 3/4 7-6 7/16

ARI Capacity Ratings for Units with AL/CU Condenser Coils (Sizes 140-350) With GreenSpeed® Intelligence

Size Capacity Total power (kW) Full load IPLV Cooler Flow Rate Cooler pressure drop
Tons kW EER COP EER COP GPM L/s ft wg kPa
140 131.7 463.1 149.5 10.6 3.1 17.3 5.1 316 19.9 13.1 39.1
160 149.5 525.7 175.2 10.2 3 17.4 5.1 358.8 22.6 12.7 37.9
180 169.2 595.2 190 10.7 3.1 17.3 5.1 406.2 25.6 15.2 45.4
200 190.2 669 220.8 10.3 3 17.5 5.1 456.5 28.8 12.8 38.1
220 211.9 745.1 242.7 10.5 3.1 17.2 5.1 508.5 32.1 15.5 46.5
240 225.4 792.7 264 10.2 3 17.5 5.1 540.9 34.1 17.4 52.1
260 251.4 884.1 284.4 10.6 3.1 17.8 5.2 603.3 38.1 10.3 30.8
280 266 935.5 303.9 10.5 3.1 17.7 5.2 638.4 40.3 11.4 34
300 281.3 989.2 327.9 10.3 3 17.8 5.2 675 42.6 12.6 37.8
325 304.2 1069.8 347.5 10.5 3.1 17.8 5.2 730 46.1 13.3 39.8
350 320.7 1127.9 367.2 10.5 3.1 17.9 5.2 769.7 48.6 14.7 43.8

ARI Capacity Ratings for Units with MCHX Condenser Coils (Sizes 140-350) With GreenSpeed® Intelligence

Size Capacity Total power (kW) Full load IPLV Cooler flow rate Cooler pressure drop
Tons kW EER COP EER COP GPM L/s ft wg kPa
140 132.6 466.4 147.2 10.8 3.2 17.5 5.1 318.3 20.1 13.2 39.6
160 150.6 529.5 172.7 10.5 3.1 17.7 5.2 361.4 22.8 12.8 38.4
180 170.4 599.3 187 10.9 3.2 17.5 5.1 409 25.8 15.4 46
200 191.5 673.6 217.9 10.5 3.1 17.8 5.2 459.7 29 12.9 38.6
220 213.5 750.8 238.8 10.7 3.1 17.5 5.1 512.4 32.3 15.8 47.1
240 227.1 798.7 259.7 10.5 3.1 17.8 5.2 545.1 34.4 17.7 52.8
260 252.6 888.4 281.5 10.8 3.2 17.9 5.2 606.2 38.2 10.4 31.1
280 267.3 940.3 300.5 10.7 3.1 17.8 5.2 641.6 40.5 11.5 34.3
300 282.6 993.8 324.8 10.4 3.1 18 5.3 678.2 42.8 12.7 38.1
325 305.1 1073.1 345 10.6 3.1 17.9 5.3 732.3 46.2 13.4 40
350 321.6 1130.9 365.1 10.6 3.1 18.1 5.3 771.8 48.7 14.7 44.1

Legend:
AL - Aluminum
COP - Coefficient of Performance
CU - Copper
EER - Energy Efficiency Ratio
IPLV - Integrated Part Load Value
MCHX - Microchannel Heat Exchanger

Notes:

  1. Rated in accordance with AHRI Standard 550/590 at standard rating conditions.
  2. Standard rating conditions are as follows:
    Cooler Conditions:
        Leaving water temperature: 44 F (6.7 C)
        Flow rate: 2.4 gpm/ton (0.043 l/s per kW)
    Fouling Factor:
        0.00010 hr x sq ft °F/Btu (0.000018 m2 x °C/W)
    Condenser Conditions:
        Entering air temperature: 95 F (35 C)
  3. Units configured with no suction service valve or suction line insultation.
  4. Unit performances will vary depending on the options configured. All data in the above tables was generated in Packaged Chiller Builder version 3.49a. Refer to the latest version of the Packaged Chiller Builder for the most up-to-date data.

Weights & Dimensions (Sizes 140-350) With GreenSpeed® Intelligence

Size Operating weight (lb) Dimensions (ft-in)
AL/CU Coil CU/CU Coil MCHX Coil Length Width Height
140 12,390 13,596 11,653 22-0 7-4 3/4 7-6 7/16
160 12,633 13,839 11,885 22-0 7-4 3/4 7-6 7/16
180 14,476 15,923 13,585 25-11 7-4 3/4 7-6 7/16
200 14,598 16,045 13,696 25-11 7-4 3/4 7-6 7/16
220 15,613 17,181 14,634 29-10 7-4 3/4 7-6 7/16
240 15,773 17,341 14,783 29-10 7-4 3/4 7-6 7/16
260 17,930 19,739 16,797 33-9 7-4 3/4 7-6 7/16
280 18,099 19,908 16,955 33-9 7-4 3/4 7-6 7/16
300 18,439 20,369 17,218 33-9 7-4 3/4 7-6 7/16
325 20,102 22,273 18,735 37-8 7-4 3/4 7-6 7/16
350 20,308 22,479 18,927 37-8 7-4 3/4 7-6 7/16

Performance Features

  • Full-load EER values up to 10.9 and IPLV values up to 15.5
  • ASHRAE 90.1 compliant / AHRI certified
  • Operation from -20 F to 125°F ambient conditions
  • High-efficiency screw compressors
  • Standard uncoated or optional e-coated Novation® microchannel heat exchanger (MCHX) condenser coils
  • Hydronic pump package, available with or without VFD on sizes 090-160
  • Touch Pilot™ display with color touch screen with trending capability and web-based connection

Reliability Features

  • ASME constructed evaporators / ETL (and ETL Canada) listed
  • Heavy-gauge galvanized steel frame
  • Security grilles and Hail guards/Privacy screen choices
  • Low ambient head pressure control
  • Coil corrosion coatings available on all coil types
  • High short circuit current rating
  • EXV (Electronic expansion valve)

Maintenance Features

  • Over 15 diagnostic functions
  • Permanently lubricated fan motor bearings
  • Compressor suction service valves
  • Microchannel condenser coils with inherent corrosion resistance and offering simplified cleaning
  • Unit-mounted, non-fused disconnect
  • Remote service port for easier machine diagnostics

Installation Features

  • Factory charged with R-134a refrigerant
  • GFI (ground fault interrupter) convenience outlet (factory-installed option or field-installed accessory)
  • Remote cooler kit (field-installed accessory)
  • Single or dual-point electrical connections available (factory-installed option)
  • Control transformer (factory-installed option)
  • Structurally robust base
  • Circuit setter provided with optional pump package (factory-installed option)

Standard Warranty

  • 3 year coil parts only on Novation microchannel heat exchanger
  • One year from start-up or 18 months from shipment limited warranty
  • Extended warranties available

Factory-Installed Options

  • Service option
  • Condenser coil trim panels
  • Full end screen
  • Hydronic pump package with or without VFD (sizes 090-160)
  • Condenser coil options:
    • Microchannel Heat Exchanger:
      • Non-coated
      • E-coated
    • Aluminum fins:
      • Non-coated
      • Pre-coated
      • E-coated
    • Copper fins:
      • Non-coated
      • E-coated
  • Non-fused disconnect
  • Security grilles
  • Energy Management Module
  • Compressor sound reduction enclosures
  • Compressor suction service valve
  • Condenser coil upper hail guards
  • BACnet™ communication
  • BACnet™ translator control
  • LON (local operating network) translator control
  • Low ambient temperature head pressure control
  • Single or dual-point electrical connection
  • High ambient temperature option
  • Touch Pilot™ display
  • Navigator™ display
  • DX cooler
  • Minus-one-pass cooler (flooded cooler only)
  • Plus-one-pass cooler (flooded cooler only)
  • Control transformer
  • Suction line insulation
  • High short circuit current rating

Field-Installed Accessories

  • Security grilles
  • Condenser coil full hail guards
  • Navigator™ display
  • GFI convenience outlet
  • Energy Management Module
  • LON (local operating network) translator control
  • BACnet™ translator control
  • Remote service port
  • Remote cooler
  • Condenser coil trim panels
  • Dual-chiller accessory kit
  • External pump control

ARI Capacity Ratings for Units with AL/CU Condenser Coils (Sizes 80-501)

Size Capacity Total power (kW) Full load IPLV Cooler flow rate Cooler pressure drop
tons kW EER COP EER COP GPM L/s ft wg kPa
80 75.6 265.9 91.6 9.9 2.9 14.2 4.2 181.3 11.4 11.7 34.9
90 84.8 298.2 95.1 10.7 3.1 14.6 4.3 203.4 12.8 11.4 34
100 93.9 330.2 107.8 10.5 3.1 15 4.4 225.4 14.2 13.7 40.9
110 102.4 360.1 118.6 10.4 3 15.2 4.4 245.8 15.5 13.9 41.5
120 110.7 389.3 129.5 10.3 3 15.2 4.4 265.7 16.8 11.9 35.5
140 132.8 467 148.7 10.7 3.1 14.4 4.2 318.8 20.1 13.3 39.7
160 152.3 535.6 173 10.6 3.1 14.8 4.3 365.5 23.1 13.1 39.1
180 171.3 602.4 192.1 10.7 3.1 14.3 4.2 411.1 25.9 15.5 46.2
200 194 682.3 217.2 10.7 3.1 14.8 4.3 465.6 29.4 13.2 39.4
220 211.7 744.5 239.6 10.6 3.1 14.5 4.2 508 32 15.5 46.2
240 228.1 802.2 264.1 10.4 3 14.8 4.3 547.5 34.5 17.8 53.1
260 250.9 882.4 281.7 10.7 3.1 14.3 4.2 602.2 38 10.3 30.7
280 268.5 944.3 301.2 10.7 3.1 14.3 4.2 644.3 40.6 11.6 34.6
300 287.5 1011.1 326.3 10.6 3.1 14.9 4.4 690 43.5 13.1 39.1
325 306.6 1078.3 347.1 10.6 3.1 14.3 4.2 735.9 46.4 13.5 40.3
350 324.1 1139.8 374.8 10.4 3 14.4 4.2 777.7 49.1 14.9 44.4
400 383.6 1349.1 449.4 10.2 3 14.8 4.3 920.7 58.1 10.4 31
401 396.3 1393.9 464 10.2 3 13.4 3.9 951.2 59.8 20.8 61.6
450 426.7 1500.6 509.2 10.1 2.9 14.1 4.1 1024.1 64.6 10.1 30.1
451 435.6 1532.2 503.9 10.4 3 13.6 4 1045.5 65.7 25.3 75.1
476 459.2 1615 554.3 9.9 2.9 14 4.1 1102 69.3 22.6 67.1
500 458 1610.7 549.1 10 2.9 14.3 4.2 1099.2 69.3 12.1 36.1
501 494.1 1737.8 580 10.2 3 13.8 4.1 1185.8 74.6 26.1 77.6

ARI Capacity Ratings for Units with MCHX Condenser Coils (Sizes 80-501)

Size Capacity Total power (kW) Full Load IPLV Cooler flow rate Cooler pressure drop
Tons kW EER COP EER COP GPM L/s ft wg kPa
80 75.8 266.6 90.1 10.1 3 14.5 4.2 182 11.5 11.8 35.2
90 85.2 299.6 93.4 10.9 3.2 14.8 4.3 204.5 12.9 11.5 34.3
100 94.4 332 105.7 10.7 3.1 15.3 4.5 226.7 14.3 13.9 41.5
110 103 362.2 116.4 10.6 3.1 15.4 4.5 247.2 15.6 14.1 42.1
120 111.4 391.8 127.2 10.5 3.1 15.5 4.5 267.4 16.9 12 35.8
140 133.4 469.1 146.4 10.9 3.2 14.7 4.3 320.1 20.2 13.4 40
160 153.1 538.4 170.1 10.8 3.2 15 4.4 367.3 23.2 13.2 39.4
180 172 604.9 189.2 10.9 3.2 14.5 4.2 412.8 26 15.6 46.5
200 194.9 685.4 213.7 10.9 3.2 15.1 4.4 467.8 29.5 13.3 39.7
220 212.7 748 235.7 10.8 3.2 14.7 4.3 510.4 32.2 15.7 46.8
240 229.2 806.1 260.1 10.6 3.1 15 4.4 550.1 34.7 18 53.7
260 251.7 885.2 278.8 10.8 3.2 14.4 4.2 604 38.1 10.3 30.7
280 269.3 947.1 298 10.8 3.2 14.5 4.2 646.3 40.8 11.6 34.6
300 288.3 1013.9 323.3 10.7 3.1 15 4.4 691.8 43.6 13.2 39.4
325 307.1 1080 344.8 10.7 3.1 14.4 4.2 737.1 46.5 13.6 40.6
350 324.5 1141.2 372.7 10.5 3.1 14.5 4.3 778.8 49.1 15 44.7
400 385 1354 444.1 10.4 3 14.9 4.4 924 58.3 10.5 31.3
401 396.8 1395.7 462 10.3 3 13.5 4 952.4 59.9 20.8 61.8
450 427.6 1503.8 505.5 10.2 3 14.2 4.2 1026.3 64.7 10.1 30.1
451 436.2 1534.1 501.7 10.4 3.1 13.8 4 1046.8 65.8 25.4 75.3
476 459.8 1617 552 10 2.9 14.1 4.1 1103.4 69.4 22.7 67.2
500 459.1 1614.6 544.8 10.1 3 14.4 4.2 1101.8 69.5 12.2 36.4
501 494.7 1740 577.3 10.3 3 14 4.1 1187.4 74.7 26.2 77.8

Legend:
AL - Aluminum
COP - Coefficient of Performance
CU - Copper
EER - Energy Efficiency Ratio
IPLV - Integrated Part Load Value
MCHX - Microchannel Heat Exchanger

Notes:

  1. Rated in accordance with AHRI Standard 550/590 at standard rating conditions.
  2. Standard rating conditions are as follows:
    Cooler Conditions:
        Leaving water temperature: 44 F (6.7 C)
        Flow rate: 2.4 gpm/ton (0.043 l/s per kW)
    Fouling Factor:
        0.00010 hr x sq ft °F/Btu (0.000018 m2 x °C/W)
    Condenser Conditions:
        Entering air temperature: 95 F (35 C)
  3. Units configured with no suction service valve or suction line insultation.
  4. Unit performances will vary depending on the options configured. All data in the above tables was generated in Packaged Chiller Builder version 3.49a. Refer to the latest version of the Packaged Chiller Builder for the most up-to-date data.

Weights & Dimensions (Sizes 80-501)

Size Operating weight (lb) Dimensions (ft-in)
AL/CU Coil CU/CU Coil MCHX Coil Length Width Height
80 7674 8398 7234 11-10 7-4 3/4 7-6 7/16
82 7831 8555 7391 11-10 7-4 3/4 7-6 7/16
90 9959 10924 9382 15-9 7-4 3/4 7-6 7/16
92 10083 11048 9506 15-9 7-4 3/4 7-6 7/16
100 10186 11151 9603 15-9 7-4 3/4 7-6 7/16
102 10310 11275 9727 15-9 7-4 3/4 7-6 7/16
110 10326 11291 9738 15-9 7-4 3/4 7-6 7/16
112 10563 11528 9975 15-9 7-4 3/4 7-6 7/16
120 10471 11436 9877 15-9 7-4 3/4 7-6 7/16
122 10681 11646 10087 15-9 7-4 3/4 7-6 7/16
140 12760 13966 12023 19-8 7-4 3/4 7-6 7/16
142 13217 14423 12480 19-8 7-4 3/4 7-6 7/16
160 13003 14209 12255 19-8 7-4 3/4 7-6 7/16
162 13429 14635 12681 19-8 7-4 3/4 7-6 7/16
180 13590 15037 12699 23-7 7-4 3/4 7-6 7/16
182 13935 15382 13044 23-7 7-4 3/4 7-6 7/16
200 13712 15159 12810 23-7 7-4 3/4 7-6 7/16
202 14014 15461 13112 23-7 7-4 3/4 7-6 7/16
220 14727 16295 13748 27-6 7-4 3/4 7-6 7/16
222 15071 16639 14092 27-6 7-4 3/4 7-6 7/16
240 14887 16455 13897 27-6 7-4 3/4 7-6 7/16
242 15231 16799 14241 27-6 7-4 3/4 7-6 7/16
260 16853 18662 15720 31-5 7-4 3/4 7-6 7/16
262 17055 18864 15922 31-5 7-4 3/4 7-6 7/16
280 17022 18831 15878 31-5 7-4 3/4 7-6 7/16
282 17224 19033 16080 31-5 7-4 3/4 7-6 7/16
300 17362 19292 16141 31-5 7-4 3/4 7-6 7/16
302 17834 19764 16613 31-5 7-4 3/4 7-6 7/16
325 18834 21005 17467 36-4 7-4 3/4 7-6 7/16
327 19306 21477 17939 36-4 7-4 3/4 7-6 7/16
350 19040 21211 17659 36-4 7-4 3/4 7-6 7/16
352 19512 21683 18131 36-4 7-4 3/4 7-6 7/16
400 24578 26990 23038 39-3 7-4 3/4 7-6 7/16
401 22690 25102 20782 39-3 7-4 3/4 7-6 7/16
450 26600 29254 24901 43-2 7-4 3/4 7-6 7/16
451 23421 26075 21324 43-2 7-4 3/4 7-6 7/16
476 27520 30174 25422 43-2 7-4 3/4 7-6 7/16
500 26894 29547 25167 43-2 7-4 3/4 7-6 7/16
501 29883 33019 27403 51-3 7-4 3/4 7-6 7/16

ARI Capacity Ratings for Units with AL/CU Condenser Coils (Sizes 140-350) With GreenSpeed® Intelligence

Size Capacity Total power (kW) Full load IPLV Cooler Flow Rate Cooler pressure drop
Tons kW EER COP EER COP GPM L/s ft wg kPa
140 131.7 463.1 149.5 10.6 3.1 17.3 5.1 316 19.9 13.1 39.1
160 149.5 525.7 175.2 10.2 3 17.4 5.1 358.8 22.6 12.7 37.9
180 169.2 595.2 190 10.7 3.1 17.3 5.1 406.2 25.6 15.2 45.4
200 190.2 669 220.8 10.3 3 17.5 5.1 456.5 28.8 12.8 38.1
220 211.9 745.1 242.7 10.5 3.1 17.2 5.1 508.5 32.1 15.5 46.5
240 225.4 792.7 264 10.2 3 17.5 5.1 540.9 34.1 17.4 52.1
260 251.4 884.1 284.4 10.6 3.1 17.8 5.2 603.3 38.1 10.3 30.8
280 266 935.5 303.9 10.5 3.1 17.7 5.2 638.4 40.3 11.4 34
300 281.3 989.2 327.9 10.3 3 17.8 5.2 675 42.6 12.6 37.8
325 304.2 1069.8 347.5 10.5 3.1 17.8 5.2 730 46.1 13.3 39.8
350 320.7 1127.9 367.2 10.5 3.1 17.9 5.2 769.7 48.6 14.7 43.8

ARI Capacity Ratings for Units with MCHX Condenser Coils (Sizes 140-350) With GreenSpeed® Intelligence

Size Capacity Total power (kW) Full load IPLV Cooler flow rate Cooler pressure drop
Tons kW EER COP EER COP GPM L/s ft wg kPa
140 132.6 466.4 147.2 10.8 3.2 17.5 5.1 318.3 20.1 13.2 39.6
160 150.6 529.5 172.7 10.5 3.1 17.7 5.2 361.4 22.8 12.8 38.4
180 170.4 599.3 187 10.9 3.2 17.5 5.1 409 25.8 15.4 46
200 191.5 673.6 217.9 10.5 3.1 17.8 5.2 459.7 29 12.9 38.6
220 213.5 750.8 238.8 10.7 3.1 17.5 5.1 512.4 32.3 15.8 47.1
240 227.1 798.7 259.7 10.5 3.1 17.8 5.2 545.1 34.4 17.7 52.8
260 252.6 888.4 281.5 10.8 3.2 17.9 5.2 606.2 38.2 10.4 31.1
280 267.3 940.3 300.5 10.7 3.1 17.8 5.2 641.6 40.5 11.5 34.3
300 282.6 993.8 324.8 10.4 3.1 18 5.3 678.2 42.8 12.7 38.1
325 305.1 1073.1 345 10.6 3.1 17.9 5.3 732.3 46.2 13.4 40
350 321.6 1130.9 365.1 10.6 3.1 18.1 5.3 771.8 48.7 14.7 44.1

Legend:
AL - Aluminum
COP - Coefficient of Performance
CU - Copper
EER - Energy Efficiency Ratio
IPLV - Integrated Part Load Value
MCHX - Microchannel Heat Exchanger

Notes:

  1. Rated in accordance with AHRI Standard 550/590 at standard rating conditions.
  2. Standard rating conditions are as follows:
    Cooler Conditions:
        Leaving water temperature: 44 F (6.7 C)
        Flow rate: 2.4 gpm/ton (0.043 l/s per kW)
    Fouling Factor:
        0.00010 hr x sq ft °F/Btu (0.000018 m2 x °C/W)
    Condenser Conditions:
        Entering air temperature: 95 F (35 C)
  3. Units configured with no suction service valve or suction line insultation.
  4. Unit performances will vary depending on the options configured. All data in the above tables was generated in Packaged Chiller Builder version 3.49a. Refer to the latest version of the Packaged Chiller Builder for the most up-to-date data.

Weights & Dimensions (Sizes 140-350) With GreenSpeed® Intelligence

Size Operating weight (lb) Dimensions (ft-in)
AL/CU Coil CU/CU Coil MCHX Coil Length Width Height
140 12,390 13,596 11,653 22-0 7-4 3/4 7-6 7/16
160 12,633 13,839 11,885 22-0 7-4 3/4 7-6 7/16
180 14,476 15,923 13,585 25-11 7-4 3/4 7-6 7/16
200 14,598 16,045 13,696 25-11 7-4 3/4 7-6 7/16
220 15,613 17,181 14,634 29-10 7-4 3/4 7-6 7/16
240 15,773 17,341 14,783 29-10 7-4 3/4 7-6 7/16
260 17,930 19,739 16,797 33-9 7-4 3/4 7-6 7/16
280 18,099 19,908 16,955 33-9 7-4 3/4 7-6 7/16
300 18,439 20,369 17,218 33-9 7-4 3/4 7-6 7/16
325 20,102 22,273 18,735 37-8 7-4 3/4 7-6 7/16
350 20,308 22,479 18,927 37-8 7-4 3/4 7-6 7/16