Skip to main content

30GTC

Air-Cooled Reciprocating Chiller

Cooling capacity: 106~387 kW

  • Mature technology and reliable operation
  • Proven 06E compressors
  • Dual refrigerant circuits and multi compressors arrangement ensures reliable system operation and flexible control
  • Compressor running time balancing
  • Efficient heat exchangers with enhanced heat transfer tubes
  • Convenient installation and ease of use
  • Microprocessor based ComfortLink control panel for simplified controls

Motor Control Center

  • Topicalized for India weather conditions from deserts to rain forests
  • Weatherproof double enclosures
  • Built-in safety separate power and control sections
  • 20 kA breaking capacity magnetic trip, ambient compensated current calibrated circuit breakers
  • Incoming power monitor with protection against under voltage, over voltage, phase reversal, phase imbalance and single phasing
  • Gound leakage current protection on compressor
  • Constant voltage to control through a CVT
  • Circuit breakers for all motors no fuses (ensure short circuit and overload protection) and saves service time

Safeties

  • High-pressure cut-out
  • Low-pressure cut-out
  • Oil pressure switch
  • High discharge gas temperature cut-out
  • Earth fault protection for compressors
  • Protection against erratic power supply
  • Protection against short circuit and overload

Compressor

  • Carrier's renowned and reliable 06E semi-hermetic, field-serviceable compressor equipped with automatically reverse oil pump
  • Compressors internally lubricated with low foaming oil
  • Industrial grade compressors operate at full capacity up to 52° C (125° F) ambient temperature

Air-Cooled Condensers

  • Carrier patented internally enhanced copper tubes for high heat transfer efficiency
  • Double sine wave aluminum fins
  • Heat exchangers designed on Carrier integrated product design software for best efficiency

Coolers

  • Internally enhanced Carrier patented copper tubes designed for 20 kg/cm² water-side pressure
  • Factory insulated with closed cell, CFC-free, elastomeric nitrile rubber insulation with low thermal conductivity and superior resistance to water vapor transmission.

Motor Control Center

  • Topicalized for India weather conditions from deserts to rain forests
  • Weatherproof double enclosures
  • Built-in safety separate power and control sections
  • 20 kA breaking capacity magnetic trip, ambient compensated current calibrated circuit breakers
  • Incoming power monitor with protection against under voltage, over voltage, phase reversal, phase imbalance and single phasing
  • Gound leakage current protection on compressor
  • Constant voltage to control through a CVT
  • Circuit breakers for all motors no fuses (ensure short circuit and overload protection) and saves service time

Safeties

  • High-pressure cut-out
  • Low-pressure cut-out
  • Oil pressure switch
  • High discharge gas temperature cut-out
  • Earth fault protection for compressors
  • Protection against erratic power supply
  • Protection against short circuit and overload

Compressor

  • Carrier's renowned and reliable 06E semi-hermetic, field-serviceable compressor equipped with automatically reverse oil pump
  • Compressors internally lubricated with low foaming oil
  • Industrial grade compressors operate at full capacity up to 52° C (125° F) ambient temperature

Air-Cooled Condensers

  • Carrier patented internally enhanced copper tubes for high heat transfer efficiency
  • Double sine wave aluminum fins
  • Heat exchangers designed on Carrier integrated product design software for best efficiency

Coolers

  • Internally enhanced Carrier patented copper tubes designed for 20 kg/cm² water-side pressure
  • Factory insulated with closed cell, CFC-free, elastomeric nitrile rubber insulation with low thermal conductivity and superior resistance to water vapor transmission.